Verena Moock

Dr. Verena Moock

Instituto de Ciencias Aplicadas y Tecnología (ICAT)
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
AHAdriana Hernández-Contreras
Adriana Hernández-Contreras
LRLeopoldo Ruiz-Huerta
Leopoldo Ruiz-Huerta
ACAlberto Caballero-Ruiz
Alberto Caballero-Ruiz
Verena MoockVerena Moock
Verena Moock
Hector SillerHector Siller
Hector Siller
Additive manufacturing (AM) is the term for a number of processes for joining materials to build physical components from a digital 3D model. AM has multiple advantages over other construction techniques, such as freeform, customization, and waste reduction. However, AM components have been evaluated by destructive and non-destructive testing and have shown mechanical issues, such as reduced resistance, anisotropy and voids. The build direction affects the mechanical properties of the built part, including voids of different characteristics. The aim of this work is an extended analysis of void shape by means of X-ray computed tomography (CT) applied to fused deposition modeling (FDM) samples. Furthermore, a relation between the tensile mechanical properties and digital void measurements is established. The results of this work demonstrate that void characteristics such as quantity, size, sphericity and compactness show no obvious variations between the samples. However, the angle between the main void axis and the mechanical load axis α shows a relation for FDM components: when its mean value μ(α) is around 80 (degrees) the yield strength and Young’s modulus are reduced. These results lead to the formulation of a novel criterion that predicts the mechanical behavior of AM components.

24 August 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Verena MoockVerena Moock
Verena Moock
BRB. Reyes-Ramírez
B. Reyes-Ramírez
CGCrescencio García-Segundo
Crescencio García-Segundo
AGAugusto García-Valenzuela
Augusto García-Valenzuela
FCFernando Arámbula Cosío
Fernando Arámbula Cosío
EGE. Garduño
E. Garduño
In photoacoustic imaging, the signal attenuation is a well-known source of artifacts over the image reconstruction. It is recognized that this is caused by optical absorption effects and by the ultrasound broadband scattering. However, the sound dispersion is generally neglected, although it appears notably in thick or heterogeneous tissues. In the present Letter, we give an experimental example in which both attenuation and sound dispersion are dealt with as relevant features to be taken into consideration. An analytic perspective of these perturbations leads us to a waveform transport-model extension that provides a linear description of the induced acoustic effects. We find a near match between the theoretical predictions and the experimental results in the frequency domain. These outcomes approximate projection data that represent forward solutions in photoacoustic image reconstruction.

1 October 2012
Verified
Conference Paper
Closed access
Verena MoockVerena Moock
Verena Moock
CGCrescencio García-Segundo
Crescencio García-Segundo
EGE. Garduno
E. Garduno
FCF. Arambula Cosio
F. Arambula Cosio
JJJithin Jose
Jithin Jose
WSW. Steenbergen
W. Steenbergen
This study examines one of the open problems yet to solve in photoacoustic tomography: How to prepare photoacoustic signals to ensure interpretation as projection data? The main part of this difficulty is related to the setting of the linear photoacoustic transport model. Notably errors are due to the discrepancy between the mathematical reconstruction and the physical realization: Tomographic image reconstruction from projections require a linear acquisition system. However in practice, the physical reality presents different non-linear phenomena. In account of this incompatibility, it was our purpose to provide some advancement in signal processing for dealing the projection issue while considering different perspectives in the interpretation of the transport model to be applied in a broader manner. Numerical examples are analyzed in detail and unveil the foundations for photoacoustic signal processing methodologies focused on the task of tomographic image reconstruction from projections.

11 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Verena MoockVerena Moock
Verena Moock
MCMarco P. Colín-García
Marco P. Colín-García
RLRubén Ezequiel Camacho López
Rubén Ezequiel Camacho López
OTOscar Eduardo Morales Toledo
Oscar Eduardo Morales Toledo
APArgelia Perez
Argelia Perez
Photoacoustic tomography is an innovative non-ionizing imaging technique that combines optical contrast with ultrasound resolution for 3D object characterization. While promising, its broader adoption is limited by challenges such as shallow penetration depth and strong optical scattering. To address these issues, this study introduces a dual illumination and detection photoacoustic tomography method, specifically designed for symmetrical objects like hollow metallic cylinders. The illumination system plays a critical role in determining the quality of photoacoustic signals and, thus, the final image. This approach enhances spatial resolution and contrast by using complementary light delivery and signal detection. In industrial settings, where accurate and efficient non-destructive testing is essential, traditional techniques often lack the precision required. The dual illumination and detection strategy offers significant improvements in effective resolution, contrast, defect detection, and artifact reduction, surpassing the limitations of unidirectional approaches. This technique not only strengthens the characterization of metal structures but also contributes to a deeper understanding of their physical behavior. Applications extend across various fields, including aerospace and biomedical engineering. This paper explores the underlying principles and potential of this advanced imaging modality, highlighting its value in modern diagnostic and inspection technologies.

19 July 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
Verena MoockVerena Moock
Verena Moock
EGEdahí Antonio Gutiérrez-Reyes
Edahí Antonio Gutiérrez-Reyes
CGCrescencio García-Segundo
Crescencio García-Segundo
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.

9 January 2024 in Journal of X-Ray Science and Technology
Verified
Journal Article
Open access
PDF file
Verena MoockVerena Moock
Verena Moock
DCDarien E. Arce Chávez
Darien E. Arce Chávez
CGCrescencio García-Segundo
Crescencio García-Segundo
LRLeopoldo Ruiz-Huerta
Leopoldo Ruiz-Huerta
BACKGROUND: The environmental impact on industrial X-ray tomography systems has gained its attention in terms of image precision and metrology over recent years, yet is still complex due to the variety of applications. OBJECTIVE: The current study explores the photothermal repercussions of the overall radiation exposure time. It shows the emerging dimensional uncertainty when measuring a stainless steel sphere by means of circular tomography scans. METHODS: The authors develop a novel frame difference method for X-ray radiographies to evaluate the spatial changes induced in the projected absorption maps on the X-ray panel. The object of interest has a simple geometry for the purpose of proof of concept. The dominant source of the observed radial uncertainty is the photothermal effect due to high-energy X-ray scattering at the metal workpiece. Thermal variations are monitored by an infrared camera within the industrial tomography system, which confines that heat in the industrial grade X-ray system. RESULTS: The authors demonstrate that dense industrial computed tomography programs with major X-ray power notably affect the uncertainty of digital dimensional measurements. The registered temperature variations are consistent with dimensional changes in radiographies and hence form a source of error that might result in visible artifacts within the 3D image reconstruction. CONCLUSIONS: This contribution is of fundamental value to reach the balance between the number of projections and radial uncertainty tolerance when performing analysis with X-ray dimensional exploration in precision measurements with industrial tomography.