Ti6Al4V (Ti64) alloy is the most used metal material for bone implants because of its good biocompatibility and adapted mechanical properties. Nevertheless, it shows low antibacterial activity, which may favor its failure. Addition of antibacterial elements such as copper should avoid this drawback. This work studies the addition of Cu into a Ti64 matrix resulting in Ti64/xCu composites. Powder mixtures of Ti64/xCu were compacted in a die and then sintered at 1100 °C. Sintering kinetics indicate that densification is achieved by pore filling due to eutectic liquid formed by the reaction of Ti and Cu. The microstructure of the sintered samples is composed mainly of α-Ti and Ti2Cu phases, but TixCuy intermetallics were also found. Microhardness is increased by the addition of Cu due to densification and the formation of harder phases such as Ti2Cu. However, the stiffness and compression strength are barely the same for all composites. The corrosion resistance is significantly improved by the addition of Cu. Finally, the material with 15 wt% of copper showed the best compromise.
This work aims to analyze the effect of pore size on the catalytic reaction of 316L stainless steel electrodes. Porous compacts were fabricated using the space holder technique and sintering at low temperatures. The fabricated porous compacts were characterized using computed tomography and the hydrogen evolution reaction was evaluated under 0.5 M and 1.5 M NaOH. Results indicate that porosity is well controlled by the pore formers, which allows different pore size distributions of pores with similar relative density values to be obtained. The pores are fully interconnected, allowing the passing of fluid throughout the compacts. Permeability is sensitive to the pore size, increasing as the pore size does. The catalytic activity of hydrogen evolution reaction HER is improved as the pore volume and pore size increase concerning the compact fabricated without pore formers. The compact that showed higher Cdl and Rf values was fabricated with S100 pore formers, which means a higher active area that favors the HER. It can be concluded that porosity enhances HER reactivity. However, larger pores are not beneficial due to a more significant permeability value.
A new processing route is proposed to produce graded porous materials by placing particles of Ti6Al4V with different sizes in different configurations to obtain bilayer samples that can be used as bone implants. The sintering behavior is studied by dilatometry and the effect of the layers’ configuration is established. To determine pore features, SEM and computed microtomography were used. Permeability is evaluated by numerical simulations in the 3D real microstructures and the mechanical properties are evaluated by compression tests. The results show that a graded porosity is obtained as a function of the size of the particle used. The mechanical anisotropy due to the pore size distribution and the sintering kinetics, can be changed by the particle layer arrangements. The Young modulus and yield stress depend on the relative density of the samples and can be roughly predicted by a power law, considering the layers’ configuration on the compression behavior. Permeability is intimately related to the median pore size that leads to anisotropy due to the layers’ configuration with smaller and coarser particles. It is concluded that the proposed processing route can produce materials with specific and graded characteristics, with the radial configuration being the most promising for biomedical applications.
This work investigates the fabrication of Ti6Al4V composites manufactured by powder metallurgy through pressureless infiltration. Porous Ti6Al4V alloy compacts with different particle sizes were fabricated by sintering and then, liquid Ag was infiltrated to obtain composites. Computed microtomography was used to analyze the samples before and after infiltration. Numerical flow simulations and dilatometry tests evaluated the kinetics of Ag infiltration into porous Ti6Al4V compacts. Microstructure was observed by SEM and mechanical strength was evaluated by compression tests. Results showed that the pore properties play a crucial role in the infiltration timing and the distribution of the Ag’s liquid. In particular, large pores allowed the infiltration to start a few °C degrees earlier than samples with smaller pores. Three-dimensional images after infiltration showed that most of the pores were filled and the remaining ones were isolated. The resulting microstructure was composed of Ti2Ag, α-Ti and Ag phases, indicating that the Ag diffusion occurred. Furthermore, the mechanical strength depends on the interparticle neck sizes and the Ag improves the plastic deformation reached during compression tests. The best results were obtained for the samples with larger pore sizes because the resulting mechanical properties (E = 23 GPa and σy = 403 MPa) are close to that of human bones, making it the best candidate as an antibacterial material for biomedical use.
Copper alloying of Ti6Al4V via liquid-phase sintering (LPS) is a promising route to enhance densification and mechanical properties for biomedical implants. This study investigates the effect of sintering temperature (900–1100 °C) on the densification, microstructure, and electrochemical behavior of Ti6Al4V–20 wt.% Cu composites. Samples were fabricated via pressureless sintering, maintaining a constant relative green density of 72.7%. The results show that the relative density increased progressively from 78.6% at 900 °C to 98.1% at 1100 °C. Microstructural analysis revealed a transition from fragmented Ti-Cu dendritic structures to refined globular intermetallic, with enhanced copper diffusion into the α-Ti matrix above 1000 °C, accompanied by the formation of TiCu and Ti2Cu intermetallic phases. Correspondingly, microhardness increased systematically from 313 HV to 473 HV, correlated with reduced porosity and intermetallic reinforcement. Electrochemical tests in Ringer’s solution indicated that while higher temperatures improve structural integrity, the distribution of Cu-rich phases significantly influences corrosion kinetics. These findings demonstrate that sintering at 1100 °C optimizes the densification–microstructure relationship, providing a technical basis for the development of high-performance Ti-based composites. Based on previous studies of Ti–Cu systems, these materials may exhibit antibacterial activity, although no biological or antibacterial tests were performed in the present work.