Watcharakorn Pinthurat

Dr. Watcharakorn Pinthurat

Rajamangala University of Technology Tawan-ok, Chon Buri, Thailand
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
Watcharakorn PinthuratWatcharakorn Pinthurat
Watcharakorn Pinthurat
TSTossaporn Surinkaew
Tossaporn Surinkaew
Branislav HredzakBranislav Hredzak
Branislav Hredzak

3 January 2023 in Electronics
Verified
Journal Article
Open access
PDF file
SWSane Lei Lei Wynn
Sane Lei Lei Wynn
Terapong BoonraksaTerapong Boonraksa
Terapong Boonraksa
PBPromphak Boonraksa
Promphak Boonraksa
Watcharakorn PinthuratWatcharakorn Pinthurat
Watcharakorn Pinthurat
Boonruang MarungsriBoonruang Marungsri
Boonruang Marungsri
Smart energy management and control systems can improve the efficient use of electricity and maintain the balance between supply and demand. This paper proposes the modeling of a decentralized energy management system (EMS) to reduce system operation costs under renewable generation and load uncertainties. There are three stages of the proposed strategy. First, this paper applies an autoregressive moving average (ARMA) model for forecasting PV and wind generations as well as power demand. Second, an optimal generation scheduling process is designed to minimize system operating costs. The well-known algorithm of particle swarm optimization (PSO) is applied to provide optimal generation scheduling among PV and WT generation systems, fuel-based generation units, and the required power from the main grid. Third, a demand response (DR) program is introduced to shift flexible load in the microgrid system to achieve an active management system. Simulation results demonstrate the performance of the proposed method using forecast data for hourly PV and WT generations and a load profile. The simulation results show that the optimal generation scheduling can minimize the operating cost under the worst-case uncertainty. The load-shifting demand response reduced peak load by 4.3% and filled the valley load by 5% in the microgrid system. The proposed optimal scheduling system provides the minimum total operation cost with a load-shifting demand response framework.

27 June 2023 in IEEE Access
Verified
Journal Article
Open access
Terapong BoonraksaTerapong Boonraksa
Terapong Boonraksa
Watcharakorn PinthuratWatcharakorn Pinthurat
Watcharakorn Pinthurat
PWPinit Wongdet
Pinit Wongdet
PBPromphak Boonraksa
Promphak Boonraksa
Boonruang MarungsriBoonruang Marungsri
Boonruang Marungsri
Branislav HredzakBranislav Hredzak
Branislav Hredzak
DC microgrid systems have been increasingly employed in recent years since there is a need to reduce the use of fossil fuels for electricity generation. Distributed generations (DGs), which are mostly DC sources in nature, play an important role in effective microgrid energy management systems. A key component in a microgrid system that can enhance stability and reliability is the employment of energy storage systems (ESSs). Nonetheless, ESSs currently lack cost-effectiveness. Each technology of the ESSs has been used for a particular purpose. Therefore, hybridization of different technologies can improve microgrid stability and reliability, as well as extend the ESS’s lifetime. This paper proposes to optimize the capacity and cost of a hybrid ESS between a battery and a supercapacitor in a standalone DC microgrid by calculating the cut-off frequency of a low-pass filter (LPF). The high fluctuation component of renewable power generation and load demand is supplied by the supercapacitor, while the low fluctuation component of renewable power generation and load demand is provided by the battery. A meta-heuristic strategy known as the Whale optimization algorithm (WOA) is applied to minimize the designed objective function, considering the total net present value (NPV) and replacement cost of the hybrid ESS, using the MATLAB environment. Real PV power, wind turbine power, and load demand are utilized for the analysis. The obtained results show that the reduction of power fluctuation for the battery in the DC microgrid can reduce the cost of the hybrid ESS. The microgrid system with only a battery has an NPVtotal of $6,153,059, whereas the hybrid ESS has an NPVtotal of $5,413,846. Thus, the hybrid ESS can reduce the total cost of the entire project by 12.01% compared to the system having only a battery. Consequently, the total system life-cycle cost of the hybrid ESS is lower than that of the battery-only system.

7 November 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
Watcharakorn PinthuratWatcharakorn Pinthurat
Watcharakorn Pinthurat
BHBranislav Hredzak
Branislav Hredzak
GKGeorgios Konstantinou
Georgios Konstantinou
JFJohn Fletcher
John Fletcher

22 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
NKNonthawat Khortsriwong
Nonthawat Khortsriwong
PBPromphak Boonraksa
Promphak Boonraksa
Terapong BoonraksaTerapong Boonraksa
Terapong Boonraksa
TFThipwan Fangsuwannarak
Thipwan Fangsuwannarak
ABAsada Boonsrirat
Asada Boonsrirat
Boonruang MarungsriBoonruang Marungsri
Boonruang Marungsri
Recently, deep learning techniques have become popular and are widely employed in several research areas, such as optimization, pattern recognition, object identification, and forecasting, due to the advanced development of computer programming technologies. A significant number of renewable energy sources (RESs) as environmentally friendly sources, especially solar photovoltaic (PV) sources, have been integrated into modern power systems. However, the PV source is highly fluctuating and difficult to predict accurately for short-term PV output power generation, leading to ineffective system planning and affecting energy security. Compared to conventional predictive approaches, such as linear regression, predictive-based deep learning methods are promising in predicting short-term PV power generation with high accuracy. This paper investigates the performance of several well-known deep learning techniques to forecast short-term PV power generation in the real-site floating PV power plant of 1.5 MWp capacity at Suranaree University of Technology Hospital, Thailand. The considered deep learning techniques include single models (RNN, CNN, LSTM, GRU, BiLSTM, and BiGRU) and hybrid models (CNN-LSTM, CNN-BiLSTM, CNN-GRU, and CNN-BiGRU). Five-minute resolution data from the real floating PV power plant is used to train and test the deep learning models. Accuracy indices of MAE, MAPE, and RMSE are applied to quantify errors between actual and forecasted values obtained from the different deep learning techniques. The obtained results show that, with the same training dataset, the performance of the deep learning models differs when testing under different weather conditions and time horizons. The CNN-BiGRU model offers the best performance for one-day PV forecasting, while the BiLSTM model is the most preferable for one-week PV forecasting.

23 January 2023 in Batteries
Verified
Journal Article
Open access
PDF file
PWPinit Wongdet
Pinit Wongdet
Terapong BoonraksaTerapong Boonraksa
Terapong Boonraksa
Promphak DawanPromphak Dawan
Promphak Dawan
Watcharakorn PinthuratWatcharakorn Pinthurat
Watcharakorn Pinthurat
Boonruang MarungsriBoonruang Marungsri
Boonruang Marungsri
Branislav HredzakBranislav Hredzak
Branislav Hredzak
In standalone microgrids, the Battery Energy Storage System (BESS) is a popular energy storage technology. Because of renewable energy generation sources such as PV and Wind Turbine (WT), the output power of a microgrid varies greatly, which can reduce the BESS lifetime. Because the BESS has a limited lifespan and is the most expensive component in a microgrid, frequent replacement significantly increases a project’s operating costs. This paper proposes a capacity optimization method as well as a cost analysis that takes the BESS lifetime into account. The weighted Wh throughput method is used in this paper to estimate the BESS lifetime. Furthermore, the well-known Particle Swarm Optimization (PSO) algorithm is employed to maximize battery capacity while minimizing the total net present value. According to simulation results, the optimal adjusting factor of 1.761 yields the lowest total net present value of US$200,653. The optimal capacity of the BESS can significantly reduce the net present value of total operation costs throughout the project by extending its lifetime. When applied to larger power systems, the proposed strategy can further reduce total costs.