Xiang Wang

Dr. Xiang Wang

City University of Hong Kong, Hong Kong, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
LXLilin Xiong
Lilin Xiong
XHXiao Huang
Xiao Huang
JLJie Li
Jie Li
Peng MaoPeng Mao
Peng Mao
XWXiang Wang
Xiang Wang
MTMeng Tang
Meng Tang
Indoor physical environments appear to influence learning efficiency nowadays. For improvement in learning efficiency, environmental scenarios need to be designed when occupants engage in different learning tasks. However, how learning efficiency is affected by indoor physical environment based on task types are still not well understood. The present study aims to explore the impacts of three physical environmental factors (i.e., temperature, noise, and illuminance) on learning efficiency according to different types of tasks, including perception, memory, problem-solving, and attention-oriented tasks. A 3 × 4 × 3 full factorial design experiment was employed in a university classroom with 10 subjects recruited. Environmental scenarios were generated based on different levels of temperature (17 °C, 22 °C, and 27 °C), noise (40 dB(A), 50 dB(A), 60 dB(A), and 70 dB(A)) and illuminance (60 lx, 300 lx, and 2200 lx). Accuracy rate (AC), reaction time (RT), and the final performance indicator (PI) were used to quantify learning efficiency. The results showed ambient temperature, noise, and illuminance exerted significant main effect on learning efficiency based on four task types. Significant concurrent effects of the three factors on final learning efficiency was found in all tasks except problem-solving-oriented task. The optimal environmental scenarios for top learning efficiency were further identified under different environmental interactions. The highest learning efficiency came in thermoneutral, relatively quiet, and bright conditions in perception-oriented task. Subjects performed best under warm, relatively quiet, and moderately light exposure when recalling images in the memory-oriented task. Learning efficiency peaked to maxima in thermoneutral, fairly quiet, and moderately light environment in problem-solving process while in cool, fairly quiet and bright environment with regard to attention-oriented task. The study provides guidance for building users to conduct effective environmental intervention with simultaneous controls of ambient temperature, noise, and illuminance. It contributes to creating the most suitable indoor physical environment for improving occupants learning efficiency according to different task types. The findings could further supplement the present indoor environment-related standards or norms with providing empirical reference on environmental interactions.

Peng MaoPeng Mao
Peng Mao
JLJie Li
Jie Li
LXLilin Xiong
Lilin Xiong
RWRubing Wang
Rubing Wang
XWXiang Wang
Xiang Wang
HLHongyang Li
Hongyang Li
Environmental quality in public rail transit has recently raised great concern, with more attention paid to underground subway microenvironment. This research aimed to provide guidance for healthy urban subway microenvironments (sub-MEs) according to comprehensive micro-environmental categories, including thermal environment, air quality, lighting environment, and acoustic environment from both practical and regulation perspectives. Field sampling experiments were conducted in Nanjing Metro Line X (NMLX). Descriptive analysis, correlation analysis and one-way analysis of variance were used to investigate the status quo of urban sub-MEs. A paired samples t-test was then performed to compare among subway station halls, platforms, and in-cabin trains based on integrated sub-MEs. Results show that relative humidity, air velocity, respirable particulate matter (PM10) concentration, and illuminance dissatisfy the requirements in relevant national standards. Significant difference was observed in lighting environment between station hall and platform. It was detected platforms are warmer and more polluted than train cabins. Additionally, subway trains generate main noise on platform which is much louder when leaving than arriving. Protective strategies for sub-ME improvement as well as principles for updating standards were proposed from a proactive point of view. The findings are beneficial for moving towards healthy urban sub-MEs and more sustainable operation of subway systems.

19 April 2020 in Engineering, Construction and Architectural Management
Verified
Journal Article
Closed access
ZXZhao Xu
Zhao Xu
XWXiang Wang
Xiang Wang
YXYa Xiao
Ya Xiao
Jingfeng YuanJingfeng Yuan
Jingfeng Yuan
Purpose: There is often a lack of accurate performance evaluation in Public–Private Partnership (PPP) projects. It is a challenging issue to effectively use Building Information Modeling (BIM) for PPP project performance evaluation. The objective of this study is to develop a PPP project performance evaluation model based on Industry Foundation Classes (IFC) and an enhanced matter-element method to more precisely evaluate PPP project performance.Design/methodology/approach: The performance evaluation of PPP projects in the construction and operation period was explored. The PPP project performance evaluation indicator system was first established based on a literature review and PPP project practice. Then, the evaluation indicator information was expressed through IFC mapping and extension. After that, an IFC-based PPP project performance evaluation model was developed, and a case study was provided to validate the use of the proposed performance evaluation model.Findings: The results of the case study show that the proposed approach can accurately and efficiently evaluate PPP projects, and it could favorably contribute to performance evaluation in PPP projects.Research limitations/implications: This study only concerns the performance evaluation of one type of PPP project. Further research is required to study different types of PPP projects; the model needs to be more efficient and intelligent.Originality/value: The performance evaluation of PPP projects utilizing IFC extension and the enhanced matter-element method provides guidance for the government and private parties to accurately and efficiently evaluate PPP project performance.

3 December 2020 in Processes
Verified
Journal Article
Open access
PDF file
ZXZhao Xu
Zhao Xu
XWXiang Wang
Xiang Wang
ZRZezhi Rao
Zezhi Rao
Background: With the ever-increasing availability of data and a higher level of automation and simulation, production scheduling in the factory for prefabrication can no longer be seen as an autonomous solution. Concepts such as building information modelling (BIM), graphic techniques, databases, and interface development as well as heightened emphasis on overall-process optimization topics increase the pressure to connect to and interact with interrelated tasks and procedures. Methods: The automated optimization framework detailed in this study intended to generate optimal schedule of prefabricated component production based on the manufacturing process model and genetic algorithm method. An extraction and segmentation approach based on industry foundation classes (IFC) for prefabricated component production is discussed. During this process, the position and geometric information of the prefabricated components are adjusted and output in the extracted IFC file. Then, the production process and the completion time of each process have been examined and simulated with the genetic algorithm. Lastly, the automated optimization solution can be formed by the linking production scheduling database and the computational environment. Results: This shows that the implementation of the automated optimization framework for the production scheduling of the prefabricated elements improves the operability and accuracy of the production process. Conclusions: Based on the integration technique discussed above, the data transmission and integration in the mating application program is achieved by linking the Python-based application, the Structured Query Language (SQL) database and the computational environment. The implementation of the automated optimization framework model enables BIM models to play a better foundational role in patching up the technical gaps between prefabricated building designers and element producers.


30 October 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
XWXiang Wang
Xiang Wang
SWShiqi Wang
Shiqi Wang
FXFu Xiao
Fu Xiao
Xiaowei LuoXiaowei Luo
Xiaowei Luo