This paper proposes an active power control method for supporting grid frequency regulation in wind farms (WF) considering improved fatigue load sensitivity of wind turbines (WT). The control method is concluded into two parts: frequency adjustment control (FAC) and power reference dispatch (PRD). On one hand, the proposed Fuzzy-PID control method can actively maintain the balance between power generation and grid load, by which the grid frequency is regulated when plenty of winds are available. The fast power response can be provided and frequency error can be reduced by the proposed method. On the other hand, the sensitivity of the WT fatigue loads to the power references is improved. The explicit analytical equations of the fatigue load sensitivity are re-derived to improve calculation accuracy. In the process of the optimization dispatch, the re-defined fatigue load sensitivity will be used to minimize fatigue load. Case studies were conducted with a WF under different grid loads and turbulent wind with different intensities. By comparing the frequency response of the WF, rainflow cycle, and Damage Equivalent Load (DEL) of the WT, the efficacy of the proposed method is verified.
Transmission line fault detection is a complex, high-cost and time-consuming work for deep-sea offshore wind farms. Therefore, rapid intelligent on-line fault detection and classification of submarine transmission lines play a very important role in the offshore wind farm reliability improving and operating costs reduction. This paper presents a novel hybrid on-line detection method that combines Wavelet noise Reduction, Clarke transform, Stockwell transform and Decision Tree (WRC-SDT). First, the measured Wind Turbine (WT) voltage signals are processed through wavelet noise reduction and Clarke transform to get the gradient of the voltage component. The gradient of the voltage component is then monitored in order to detect faults. Second, the recorded WT current date are processed through Stockwell transform with a view to obtaining the transmission line fault eigenvalues. The fault eigenvalues are then taken as the input of decision tree in order to classify different types of faults. To verify the feasibility and performance of the proposed method, the comparison of a detection and classification result is presented based on more than 1600 fault simulation data. The results show that WRC-SDT method is immune to fault resistance, starting angle and location. The proposed method is also robust to measurement noise.
1 May 2023 in Journal of Renewable and Sustainable Energy
Wind turbines' participation in frequency response is known to improve the frequency stability of power systems, but it can also have a negative impact on the fatigue load of wind turbines. The objective of this paper is to investigate the effect of frequency response on the fatigue loads experienced by various components of a wind turbine, including the low-speed shaft, tower, and blade. To achieve this goal, the authors develop a model of a variable speed horizontal-axis wind turbine based on a doubly fed induction generator. They derive explicit analytical equations of low-speed shaft torque, tower bending moment, and blade bending moment to describe the fluctuations of torque and moment related to the operating states of wind turbines, such as generator torque, rotor speed, and pitch angle, under frequency response. These equations allow for the evaluation of the impact of frequency response on torque and moment changes and fatigue load. Spectral density analysis and modal analysis are used to further analyze the analytical equations, examining the influence of frequency response on different operating conditions of wind turbines and determining the mechanism by which frequency response affects fatigue load qualitatively and quantitatively. The authors use the FAST V8 Code based on the NREL offshore 5-MW baseline wind turbine to demonstrate the effectiveness of the proposed analysis method in evaluating fatigue loads affected by frequency response. The results show that the fatigue load on the low-speed shaft and the lateral side of the tower will significantly increase due to wind turbine participation in frequency response.
This study primarily analyzes the frequency regulation capability and fatigue loads of wind turbines based on over-speed control. Initially, a small-signal model of the wind turbine is established, which describes the output characteristics of the wind turbine under different control modes and wind speeds. Next, the model is used to analyze the wind turbine’s frequency regulation capability and to calculate the optimal frequency regulation parameter range based on the phase margin. Finally, a combination of frequency domain and time domain analysis is used to examine the influence of over-speed control on the fatigue loads of low-speed shafts, towers, and blades, which determines the wind speed range suitable for frequency regulation. The Fast (Fatigue, Aerodynamics, Structures, and Turbulence) Code V8 is used to simulate the dynamic characteristics of the wind turbine.
1 May 2019 in Journal of Renewable and Sustainable Energy
Reasonable active power dispatch for wind farms can reduce the dynamic fatigue loads of wind turbines (WTs) and prolong the service lives of the WTs. An active power dispatch method for wind farms based on the improved fatigue load sensitivity of WT is proposed. According to the WT operating parameters, the fatigue load sensitivity to the power reference value is improved. The analytical equations of the fatigue load sensitivity are rederived, and the accuracies of the fatigue load sensitivity calculations are improved. The wind farm fatigue load minimization is taken as the target, the tracking power reference value is taken as the constraint, and the active power distribution model is established. The quadratic programming optimization algorithm is used to calculate the power reference of each WT. Case studies were conducted with wind farm control for different turbulent winds. The effectiveness of the proposed method is verified by comparing the rainflow cycles and the damage equivalent load.