17 March 2020 in IEEE Access
Transmission line fault detection is a complex, high-cost and time-consuming work for deep-sea offshore wind farms. Therefore, rapid intelligent on-line fault detection and classification of submarine transmission lines play a very important role in the offshore wind farm reliability improving and operating costs reduction. This paper presents a novel hybrid on-line detection method that combines Wavelet noise Reduction, Clarke transform, Stockwell transform and Decision Tree (WRC-SDT). First, the measured Wind Turbine (WT) voltage signals are processed through wavelet noise reduction and Clarke transform to get the gradient of the voltage component. The gradient of the voltage component is then monitored in order to detect faults. Second, the recorded WT current date are processed through Stockwell transform with a view to obtaining the transmission line fault eigenvalues. The fault eigenvalues are then taken as the input of decision tree in order to classify different types of faults. To verify the feasibility and performance of the proposed method, the comparison of a detection and classification result is presented based on more than 1600 fault simulation data. The results show that WRC-SDT method is immune to fault resistance, starting angle and location. The proposed method is also robust to measurement noise.
16 April 2021 in IET Renewable Power Generation
Due to the difficulty and time‐consumption in locating short‐distance transmission lines for deep‐sea offshore wind farm (DOWF),this paper proposes a novel double‐terminal fault location method by using Stockwell‐transform (ST) and random‐forest (RF). After the fault type and branch are accurately determined, the accurate transmission line fault location is located. Firstly, Stockwell‐transform is employed to extract fault eigenvalues from the collected wind turbine (WT) current signals, which will reduce the sensitivity of eigenvalues to noise. And the Pearson correlation coefficient (PCC) is introduced to remove duplicate eigenvalues. Secondly, the reserved fault eigenvalues are taken as inputs to the different random‐forest to classify fault types and identify the fault branch, respectively. Finally, the double‐terminal fault location principle is established in fault negative sequence network (only ABCG uses positive sequence components). Newton‐Raphson method (NRM) is used to eliminate the influence of asynchrony data, which implies an accurate transmission line fault location for deep‐sea offshore wind farm. More than 4000 fault cases data obtained by Simulink simulation verify the feasibility and performance of the proposed method. The results show that the proposed location method has a high fault recognition rate and is immune to fault inception angle, resistance, location and noise.
1 September 2013 in Physics of Fluids
Instability of a suspension is directly related to the problem of the cross-stream migration of a particle relative to its neighboring particle suspension. Such cross-stream or lateral migration of a single non-spherical particle (fiber) settling in a bounded weak shear flow with vertical streamlines produced by a perturbation to the fiber number density is studied using lattice Boltzmann simulations. The present simulation results demonstrate that at a given shear rate, the lateral migration can be divided into three phases depending on settling Reynolds number Rsd and particle aspect ratio κ. At a low settling Reynolds number Rsd, the suspension becomes more stable in phase 1. As Rsd increases and excesses a critical settling Reynolds number Rsd1, the fiber suspension becomes unstable in phase 2. In phase 3, at an enough large Rsd, the inertia dominates the weak shear flow and it may have little effect on stability. A mechanism of the instability induced by an inertial fiber orientation drift and a shear induced cross-streamline drift, recently proposed by Shin, Koch, and Subramanian [“Structure and dynamics of dilute suspensions of finite reynolds number settling fibers,” Phys. Fluids 21, 123304 (2009)], is examined and confirmed.
5 October 2022 in IEEE Access
Considering the mutual coupling effect of wind turbine control parameters, an optimization method of the control parameters for torque system based on drive chain active damping control is proposed, which improves the control accuracy and solves the problem that the control objectives are difficult to coordinate. Firstly, the mathematical model of the torque-speed system and the dynamical model of the drive chain active damping control are established. At the same time, the initial value of active damping gain is calculated according to the designed band-pass filter measurement results. Secondly, to facilitate the setting of proportional-integral (PI) control parameters, the Routh method is adopted to identify the torque-speed system with large inertia characteristic as a low-order inertia system. Subsequently, the Integrated Time and Absolute Error (ITAE) criterion is used to set the initial value of the PI control parameters for the torque system. Furthermore, the PI control parameters and active damping gains at each equilibrium point are optimized based on the Hierarchic Genetic Algorithm, which improves the accuracy of control parameters. At the same time, the control objectives are coordinated by optimizing weight allocation based on the Pareto. Then the adaptive control method is constructed by fitting them with the wind speed to improve the control accuracy far from the equilibrium points. Finally, the effectiveness of the proposed method is verified by comparing the frequency-domain characteristic, control accuracy, twist vibration of the drive chain, tower vibration and load.
1 August 2026 in IEEE Sensors Journal