This study aimed to identify the role of crosslinking agents in the resin–dentin bond strength (BS) when used as modifiers in adhesives or pretreatments to the dentin surface through a systematic review and meta-analysis. This paper was conducted according to the directions of the PRISMA 2020 statement. The research question of this review was: “Would the use of crosslinkers agents improve the BS of resin-based materials to dentin?” The literature search was conducted in the following databases: Embase, PubMed, Scielo, Scopus, and Web of Science. Manuscripts that reported the effect on the BS after the use of crosslinking agents were included. The meta-analyses were performed using Review Manager v5.4.1. The comparisons were performed by comparing the standardized mean difference between the BS values obtained using the crosslinker agent or the control group. The subgroup comparisons were performed based on the adhesive strategy used (total-etch or self-etch). The immediate and long-term data were analyzed separately. A total of 50 articles were included in the qualitative analysis, while 45 articles were considered for the quantitative analysis. The meta-analysis suggested that pretreatment with epigallocatechin-3-gallate (EGCG), carbodiimide, ethylenediaminetetraacetic acid (EDTA), glutaraldehyde, and riboflavin crosslinking agents improved the long-term BS of resin composites to dentin (p ≤ 0.02). On the other hand, the use of proanthocyanidins as a pretreatment improved both the immediate and long-term BS values (p ≤ 0.02). When incorporated within the adhesive formulation, only glutaraldehyde, riboflavin, and EGCG improved the long-term BS to dentin. It could be concluded that the application of different crosslinking agents such as carbodiimide, EDTA, glutaraldehyde, riboflavin, and EGCG improved the long-term BS of adhesive systems to dentin. This effect was observed when these crosslinkers were used as a separate step and when incorporated within the formulation of the adhesive system.
Tooth wear is considered a well-developed issue in daily clinical practice; however, there is no standard protocol for treatment. The aim of this manuscript was to systematically review the literature to evaluate the clinical outcomes of direct or indirect restorations for treating tooth wear. A literature search was conducted through the PubMed MedLine, Scopus, ISI Web of Science, Scielo, and EMBASE databases up to 29 April 2022. Clinical studies evaluating the clinical performance of direct or indirect restorations for treating tooth wear for a minimum follow-up of 6 months were included in the review. A total of 2776 records were obtained from the search databases. After full-text reading, 16 studies were included in the qualitative analysis. Considering the high heterogenicity of the studies included, a meta-analysis could not be performed. All studies included the rehabilitation of anterior and posterior teeth with extensive wear, using both indirect and direct restorations for a maximum follow-up of 10 years. Restoration materials included ceramo-metal crowns, full gold crowns, lithium disilicate ceramic, zirconia, polymer infiltrated ceramic networks, and resin composites. Most of the reports assessed the survival rate of the restorations and the clinical features using the United States Public Health Service (USPHS) Evaluation System criteria. Contradictory discoveries were perceived concerning the type of restoration with better clinical performance. Considering the current literature available, there is no evidence in the superiority of any restoration technique to ensure the highest clinical performance for treating tooth wear.
1 January 2023 in The Journal of Advanced Prosthodontics
Various material properties are involved in the success of endodontically treated restorations. At present, restorative composites are commonly employed as core build-up materials. This study aimed to systematically review the literature to assess the effect of using composite core materials on the in vitro fracture of endodontically treated teeth. Two different reviewers screened the literature, up to June 2021, in five distinct electronic databases: PubMed (MedLine), Scopus, Scielo, ISI Web of Science, and EMBASE. Only in vitro studies reporting the effect of the use of composite core materials on the fracture resistance of endodontically treated teeth were included. A meta-analysis was carried out using a software program (Review Manager v5.4.1; The Cochrane Collaboration, Copenhagen, Denmark). The risk of bias in each study was assessed following the parameters of another systematic review. A total of 5016 relevant papers were retrieved from all databases. After assessing the title and abstract, five publications remained for qualitative analysis. From these, only three studies remained for meta-analysis. The fracture strength of endodontically treated teeth where a core build-up composite was used was statistically significantly higher than the control (p = 0.04). Most of the analyses showed a high heterogenicity. The in vitro evidence suggests that the composite core build-up with higher filler content tended to improve the fracture resistance of the endodontically treated teeth, in comparison with conventional composite resins. This research received no external funding. Considering that this systematic review was only carried out on in vitro papers, registration was not performed. Furthermore, there were no identified clinical studies assessing core build-up materials; therefore, more well-designed research on these materials is needed.
The objective was to evaluate the influence of active bonding applications (ABA) for different time intervals after selective dentin etching (SDE) for 3 s on the microtensile bond strength (μTBS) to dentin of two universal adhesive systems (UAs): one containing 2-hydroxyethyl methacrylate (HEMA) (Scotchbond Universal, SBU), and one that was HEMA-free (Prime&Bond Universal, PBU). Dentin bovine specimens were divided into four groups: self-etch as control (SE), SDE + ABA for 15 s (SDE15), SDE + ABA for 20 s (SDE20), and SDE + ABA for 25 s (SDE25). The μTBS test was performed after a water storage of 24 h and 6 months. Scanning electron microscopy (SEM) was used in order to examine the resin–dentin interface. For the PBU, the µTBS was significantly influenced only by the aging factor (p < 0.026). A statistically significant decrease in the µTBS after 6 months of aging was observed only for the SDE15 group. For SBU, µTBS was significantly influenced by the protocol application and the aging time (p ≤ 0.041). The groups SDE15, SDE20, and SDE25 achieved statistically significant higher values (after 24 h and 6 months). No considerable variances were noticed in the homogeneity and continuity of the hybrid layer (HL) among the groups. In conclusion, SDE and ABA improved the µTBS only of a HEMA-containing universal adhesive.
Currently, there is no consensus in terms of defining the minimum radiant exposure values necessary for achieving adequate properties of composite resin. In addition, the long-term influence that radiant exposure has on the properties of composite resins is still questionable. Objective: The objective of this study was to evaluate the effect of radiant exposure and UV accelerated aging on the physico-chemical and mechanical properties of micro-hybrid and nanofilled composite resins. Material and Methods: A nanofilled (Filtek Supreme; 3M ESPE) and a micro-hybrid composite resin (Filtek Z250; 3M ESPE) were investigated under different radiant exposures (3.75, 9, and 24 J/cm2) and UV accelerated aging protocols (0, 500, 1000, and 1500 aging hours). The degree of conversion (DC), flexural strength (FS), modulus (M), water sorption (WS), and solubility (WL) were evaluated. The results obtained were analyzed using two-way ANOVA and Tukey's test. Comparisons were performed using a significance level of α=0.05. Results: The DC, FS, and M were found to be significantly influenced by both radiant exposure and accelerated aging time. The DC and EM increased with radiant exposure in the no-aging group (0-hour aging) for both micro-hybrid and nanofilled composites, whereas no correlation was found after accelerated aging protocols. WS and WL of micro-hybrid and nanofilled composite resins were scarcely affected by radiant exposure (p>0.05), whereas they were significantly reduced by accelerated aging (p<0.001). Conclusions: Although increasing radiant exposure affected the degree of conversion and mechanical properties of micro-hybrid and nanofilled composites, no influence on the hydrolytic degradation of the material was observed. In contrast, UV accelerated aging affected both the physico-chemical and mechanical properties of the composites.