Zhiyong Chen

Dr. Zhiyong Chen

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Engineering Structures
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
EZEnchun Zhu
Enchun Zhu
FLFrank Lam
Frank Lam
JPJinglong Pan
Jinglong Pan

1 April 2020 in Journal of Structural Engineering
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
MPMarjan Popovski
Marjan Popovski
AIAsif Iqbal
Asif Iqbal
The prestressed-laminated timber (Pres-Lam) system is an innovative low-damage wood-hybrid system that utilizes post-tensioned (PT) mass timber components, e.g., laminated veneer lumber (LVL), glued laminated timber (glulam), and cross laminated timber (CLT), along with various types of energy dissipators, e.g., axial energy dissipators (also called fuses) and U-shaped flexural plates (UFPs). Previous tests carried out on this system focused on scaled (one-third or two-thirds) LVL specimens, whereas limited studies have been conducted on the Pres-Lam system with CLT which has mechanical properties and composition different from LVL. Through comprehensive tests, the lateral-load response of PT-only and Pres-Lam CLT shear walls was investigated in this study. A total of 14 different full-scale PT-only and Pres-Lam CLT walls in four configurations were tested under monotonic and reversed cyclic loading. A user-friendly fuse was designed and adopted in the Pres-Lam CLT wall specimens. PT-only and Pres-Lam CLT shear walls had bilinear elastic and elastic-plastic behavior, respectively, with a stretching point corresponding to the state at which the PT force started to increase. With energy dissipators, Pres-Lam CLT shear walls had higher resistance, maximum lateral drift and energy dissipation compared to PT-only walls. The influence of the initial PT force, the fuse spacing, and the number of UFPs on the stiffness, resistance, maximum lateral drift and energy dissipation of the wall specimens was discussed. The test results also show that the behavior of the Pres-Lam CLT shear walls can be decoupled and a superposition rule can be applied to obtain the stiffness and resistance of such systems. Yielding and buckling of the fuses occurred at the early stage of loading as designed, and localized crushing of wood at the end of panels happened when the lateral drift was at or beyond 2.5%. The test results gave a valuable insight into the structural behavior of the PT-only and Pres-Lam CLT shear walls under in-plane lateral loads.

1 June 2016 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
EZEnchun Zhu
Enchun Zhu
JPJinglong Pan
Jinglong Pan
GWGuofang Wu
Guofang Wu

1 March 2020 in Journal of Structural Engineering
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
CNChun Ni
Chun Ni
CDChristian Dagenais
Christian Dagenais
SKSteven Kuan
Steven Kuan
The thermomechanical behavior of members and connections plays a crucial role in the fire safety of timber construction. In this study, a unique constitutive model, WoodST , combining a number of mechanics-based submodels was developed for numerical simulation of wood-based materials and connections under forces and fire. The extended Yamada–Sun strength criteria were utilized to judge the brittle failure or ductile yielding in different directions and stress conditions. A strain-based damage evolution was developed to describe the postpeak softening of brittle failure in tension or shear. A plastic flow and a hardening law were established based on the strength criteria to depict the plastic stress-strain relationship of ductile yielding in compression. A strain-based hardening evolution was developed to implement a second hardening (densification) under compression perpendicular to grain. A multilinear reduction model was adopted to represent the influence of fire on the mechanical properties of wood-based materials. The developed model was used to model the structural response of a laminated veneer lumber (LVL) beam and a glulam bolted connection under force and fire. It is demonstrated that the proposed constitutive model was capable of simulating the thermomechanical response of LVL beam and glulam connection under force and fire within 10% difference between modeling and testing results.

1 June 2020 in Engineering Structures
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
MPMarjan Popovski
Marjan Popovski

1 November 2020 in Engineering Structures
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
MPMarjan Popovski
Marjan Popovski
CNChun Ni
Chun Ni