Christian Dagenais

Dr. Christian Dagenais

FPInnovations, Quebec, QC G1V 4C7, Canada
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2020 in Buildings
Verified
Journal Article
Open access
PDF file
KKKristina Kincelova
Kristina Kincelova
CBConrad Boton
Conrad Boton
Pierre BlanchetPierre Blanchet
Pierre Blanchet
CDChristian Dagenais
Christian Dagenais
Fire safety regulations impose very strict requirements on building design, especially for buildings built with combustible materials. It is believed that it is possible to improve the management of these regulations with a better integration of fire protection aspects in the building information modeling (BIM) approach. A new BIM-based domain is emerging, the automated code checking, with its growing number of dedicated approaches. However, only very few of these works have been dedicated to managing the compliance to fire safety regulations in timber buildings. In this paper, the applicability to fire safety in the Canadian context is studied by constituting and executing a complete method from the regulations text through code-checking construction to result analysis. A design science approach is used to propose a code-checking method with a detailed analysis of the National Building Code of Canada (NBCC) in order to obtain the required information. The method starts by retrieving information from the regulation text, leading to a compliance check of an architectural building model. Then, the method is tested on a set of fire safety regulations and validated on a building model from a real project. The selected fire safety rules set a solid basis for further development of checking rules for the field of fire safety. This study shows that the main challenges for rule checking are the modeling standards and the elements’ required levels of detail. The implementation of the method was successful for geometrical as well as non-geometrical requirements, although further work is needed for more advanced geometrical studies, such as sprinkler or fire dampers positioning.

1 March 2020 in Journal of Structural Engineering
Verified
Journal Article
Closed access
Zhiyong ChenZhiyong Chen
Zhiyong Chen
CNChun Ni
Chun Ni
CDChristian Dagenais
Christian Dagenais
SKSteven Kuan
Steven Kuan
The thermomechanical behavior of members and connections plays a crucial role in the fire safety of timber construction. In this study, a unique constitutive model, WoodST , combining a number of mechanics-based submodels was developed for numerical simulation of wood-based materials and connections under forces and fire. The extended Yamada–Sun strength criteria were utilized to judge the brittle failure or ductile yielding in different directions and stress conditions. A strain-based damage evolution was developed to describe the postpeak softening of brittle failure in tension or shear. A plastic flow and a hardening law were established based on the strength criteria to depict the plastic stress-strain relationship of ductile yielding in compression. A strain-based hardening evolution was developed to implement a second hardening (densification) under compression perpendicular to grain. A multilinear reduction model was adopted to represent the influence of fire on the mechanical properties of wood-based materials. The developed model was used to model the structural response of a laminated veneer lumber (LVL) beam and a glulam bolted connection under force and fire. It is demonstrated that the proposed constitutive model was capable of simulating the thermomechanical response of LVL beam and glulam connection under force and fire within 10% difference between modeling and testing results.

20 October 2021 in Coatings
Verified
Journal Article
Open access
PDF file
AHAtif Hussain
Atif Hussain
VLVéronic Landry
Véronic Landry
Pierre BlanchetPierre Blanchet
Pierre Blanchet
DHDoan-Trang Hoang
Doan-Trang Hoang
CDChristian Dagenais
Christian Dagenais
In this work, intumescent coatings were prepared for protection of wood from fire. The fire-retardant chemical ammonium polyphosphate (APP) is known to have poor resistance to water and high humidity as it is hygroscopic in nature. To improve the water resistance, durability and fire resistance of the intumescent coating, APP was modified using a hybrid organic-inorganic polysiloxane encapsulation shell prepared by the sol–gel method. The physical and chemical properties of the intumescent mix containing microencapsulated ammonium polyphosphate (EAPP) particles were characterized by X-ray fluorescence (XRF), Fourier transform infrared spectroscopy (FTIR), water absorption, dynamic vapor sorption (DVS) and thermogravimetric analysis (TGA). The EAPP mix showed 50% reduction in water absorption, 75% reduction in water vapor sorption and increased thermal stability when compared to the APP mix. The intumescent coatings were applied on wood samples, and their fire performance was evaluated using a cone calorimeter test. The intumescent coatings containing EAPP mix showed better fire retarding properties with longer time to ignition, lower heat release rate and shorter heat release peak when compared to the coating without EAPP mix. The prepared intumescent coating shows higher resistance to water and moisture, and it has great potential to be used in bio-based construction industry for enhancing the fire resistance of wood.

16 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MLMathieu Létourneau-Gagnon
Mathieu Létourneau-Gagnon
CDChristian Dagenais
Christian Dagenais
Pierre BlanchetPierre Blanchet
Pierre Blanchet
Building elements are required to provide sufficient fire resistance based on requirements set forth in the National Building Code of Canada (NBCC). Annex B of the Canadian standard for wood engineering design (CSA O86-19) provides a design methodology to calculate the structural fire-resistance of large cross-section timber elements. However, it lacks at providing design provisions for connections. The objectives of this study are to understand the fire performance of modern mass timber fasteners such as self-tapping screws, namely to evaluate their thermo-mechanical behavior and to predict their structural fire-resistance for standard fire exposure up to two hours, as would be required for tall buildings in Canada. The results present the great fire performance of using self-tapping screws under a long time exposure on connections in mass timber construction. The smaller heated area of the exposed surface has limited thermal conduction along the fastener’s shanks and maintained their temperature profiles relatively low for two hours of exposure. Based on the heat-affected area, the study presents new design principles to determine the residual length of penetration that would provide adequate load-capacity of the fastener under fire conditions. It also allows determining safe fire-resistance values for unprotected fasteners in mass timber construction exposed up to two hours of standard fire exposure.

19 September 2019 in Buildings
Verified
Journal Article
Open access
PDF file
NGNataliia Gerzhova
Nataliia Gerzhova
Pierre BlanchetPierre Blanchet
Pierre Blanchet
CDChristian Dagenais
Christian Dagenais
JCJean Côté
Jean Côté
SMSylvain Menard
Sylvain Menard
Currently, green roof fire risks are not clearly defined. This is because the problem is still not well understood, which raises concerns. The possibility of plants catching fire, especially during drought periods, is one of the reasons for necessary protection measures. The potential fire hazard for roof decks covered with vegetation has not yet been fully explored. The present study analyzes the performance of green roofs in extreme heat conditions by simulating a heat transfer process through the assembly. The main objective of this study was to determine the conditions and time required for the roof deck to reach a critical temperature. The effects of growing medium layer thickness (between 3 and 10 cm), porosity (0.5 to 0.7), and heating intensity (50, 100, 150, and 200 kW/m2) were examined. It was found that a green roof can protect a wooden roof deck from igniting with only 3 cm of soil coverage when exposed to severe heat fluxes for at least 25 minutes. The dependency of failure time on substrate thickness decreases with increasing heating load. It was also found that substrate porosity has a low impact on time to failure, and only at high heating loads.

9 July 2020 in Buildings
Verified
Journal Article
Open access
PDF file
NGNataliia Gerzhova
Nataliia Gerzhova
Pierre BlanchetPierre Blanchet
Pierre Blanchet
CDChristian Dagenais
Christian Dagenais
SMSylvain Menard
Sylvain Menard
JCJean Côté
Jean Côté
Assessing the fire risk of vegetated roofs includes the determination of their possible contribution to fire. Green roof components such as plants and growing media are organic materials and present a fuel that can catch and support the spread of fire. The flammability characteristics of these components were analyzed and compared to a typical roof covering. Growing media with 15% of organic matter were tested using cone calorimeter apparatus. The fuel load and heat release rate of the growing media were measured in both moist (30%) and dry conditions. It was observed that growing media in a moist condition do not present a fire risk, reaching a maximum heat release rate of 33 kW/m2. For dry substrates, a peak heat release rate of 95 kW/m2 was recorded in the first minute, which then rapidly decreased to 29 kW/m2 in the second minute. Compared to a typical bitumen roof membrane, the green roof showed a better fire performance. The literature data report more severe results for plant behavior, reaching peak heat release rates (HRRs) of 397 kW/m2 for dried and 176 kW/m2 for a green material. However, a rapid decrease in HRR to much lower values occurs in less than 2 min. The results also show that extensive and intensive types of green roofs present 22% and 95% of the additional fire load density when installed on a modified bitumen membrane, 19.7 and 85.8 MJ/m2, respectively.