Optimization of schemes for black-start is one of the most important factors determining the speed of power system restoration after either a global blackout or a local outage. In this paper a novel method employing the entropy weight-based decision-making theory is proposed for this application. By using the method for the decision making in black start, the subjective weights acquired from knowledge and experience of experts could be used in conjunction with the objective weights (entropy weighs) deduced from some closely related indices. Obviously, the developed method can greatly improve the performance in power system restoration by overcoming the shortcomings of conventional methods that only use either the subjective or the objective weights. Furthermore, the proposed method is applicable in power systems with different levels of black-start experience for assisting the optimal black-start decision making. It is shown that the proposed method is suitable for power systems with different levels of b...
1 February 2020 in IEEE Transactions on Dielectrics and Electrical Insulation
Consumers' transformers play an important role in power systems, and they are essential for operation reliability and commercial benefits. In the past, maintenance personnel had to spend plenty of time on examining consumers' transformers one by one. Nowadays, with the wide deployment of power user electric energy data acquire system (PUEEDAS), informative metering data are becoming available, which can be utilized for further condition monitoring. Thus, this paper proposes a data-driven abnormal condition monitoring algorithm of data acquisition for consumers' transformers, which could send abnormal condition alerts to operators and maintenance personnel timely. In the proposed algorithm, Spearman's rank correlation coefficient is utilized to show the degree of correlation among phase currents, and its t-statistics is used to determine whether abnormal condition of data acquisition exists based on the hypothesis testing. Finally, actual acquisition data from Zhejiang power system in China are employed to validate the effectiveness of the proposed algorithm, and to analyze the characteristics of normal and abnormal conditions respectively. Sensitive analyses on different significant levels and sampling rates are performed for considering its impact on monitoring results; and the application in real power systems is also given to demonstrate the practicality of the proposed algorithm.
This paper presents an investigation on DC flashover voltage of silicone rubber (SiR) improved by dielectric barrier discharge (DBD) plasma treatments under ambient atmospheric pressure air. DC surface conductivity, surface potential decay (SPD), DC surface flashover voltage, partial discharge magnitude, Fourier transform infrared (FT-IR) spectrograms, and surface water contact angles are measured to analyze the influence of plasma treatment on the SiR. It is found that the speed of SPD increase consistently with the plasma modification time. The tendency of flashover voltage is increasing at first and then decreasing with the increased time of the plasma treatment. The magnitude and number of partial discharge pulses increase apparently with the increased plasma treatment time. Physicochemical measurements indicate that more amount of polar groups appear on surface after the DBD plasma modification, whereas the surface water contact angles decline continuously with the increased plasma modification time. However, the hydrophobicity is recovered after 30 d exposure in the air. It is demonstrated that the SPD is accelerated significantly due to the increased surface conductivities and density of shallow traps. However, the reduction of flashover voltage after longer time of the plasma treatment is attributed to the increased mobility of charge carriers on the sample surface.
The development of emerging technologies has enhanced the demand response (DR) capability of conventional loads. To study the effect of DR on the reduction in carbon emissions in an integrated energy system (IES), a two-stage low-carbon economic dispatch model based on the carbon emission flow (CEF) theory was proposed in this study. In the first stage, the energy supply cost was taken as the objective function for economic dispatch, and the actual carbon emissions of each energy hub (EH) were calculated based on the CEF theory. In the second stage, a low-carbon DR optimization was performed with the objective function of the load-side carbon trading cost. Then, based on the modified IEEE 39-bus power system/Belgian 20-node natural gas system, MATLAB/Gurobi was used for the simulation analysis in three scenarios. The results showed that the proposed model could effectively promote the system to reduce the load peak-to-valley difference, enhance the ability to consume wind power, and reduce the carbon emissions and carbon trading cost. Furthermore, as the wind power penetration rate increased from 20% to 80%, the carbon reduction effect basically remained stable. Therefore, with the growth of renewable energy, the proposed model can still effectively reduce carbon emissions.