Purpose: This paper presents a novel method for identifying damage in reinforced concrete (RC) bridges, utilizing macro-strain data from distributed long-gauge sensors installed on the concrete surface.Design/methodology/approach: The method relies on the principle that heavy vehicles induce larger dynamic vibrations, leading to increased strain and crack formation compared to lighter vehicles. By comparing the absolute macro-strain ratio (AMSR) of a reference sensor with a network of distributed sensors, damage locations can be effectively pinpointed from a single data collection session. Finite-element modeling was employed to validate the method's efficacy, demonstrating that the AMSR ratio increases significantly in the presence of cracks. Experimental validation was conducted on a real-world bridge in Japan, confirming the method's reliability under normal traffic conditions.Findings: This approach offers a practical and efficient means of detecting bridge damage, potentially enhancing the safety and longevity of infrastructure systems.Originality/value: Original research paper.
This study investigates the axial compression behavior of square reinforced concrete (RC) columns confined by a novel type of rectangular closed basalt fiber-reinforced polymer (BFRP) tie fabricated using a continuous filament winding method, and hybrid steel–BFRP configurations. The proposed ties were developed to overcome common limitations of conventional FRP stirrups, such as reduced tensile strength at bent regions and premature rupture. A total of five RC column specimens were tested under monotonic axial loading: one reference specimen with conventional steel ties, two specimens with BFRP ties spaced at 45 mm and 90 mm, and two hybrid specimens combining steel and BFRP ties. Experimental results showed that the steel-confined column achieved the highest peak axial load of 1793.2 kN and an ultimate strain value of 1.12. The specimen with closely spaced BFRP ties (45 mm) reached 94.7% of the peak load of the steel-confined specimen and exhibited over 137% higher axial strain capacity. The hybrid specimen with two interleaved BFRP ties achieved the highest confinement effectiveness ratio of 1.306. The findings demonstrate that the proposed BFRP ties offer a structurally viable and corrosion-resistant alternative to steel ties, particularly when used in hybrid systems. This research contributes to the development of durable, high-performance confinement strategies for RC columns in seismic and aggressive environmental conditions.
3 July 2025 in Iranian Journal of Science and Technology, Transactions of Civil Engineering