Ahmet Yüksel

Dr. Ahmet Yüksel

Electricity and Energy, Yalova University, Yalova, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Journal of Building Engineering
Verified
Journal Article
Closed access
Ahmet YükselAhmet Yüksel
Ahmet Yüksel
Muslum AriciMuslum Arici
Muslum Arici
MKMichal Krajčík
Michal Krajčík
MCMihriban Civan
Mihriban Civan
HKHasan Karabay
Hasan Karabay

13 April 2022 in Journal of Cleaner Production
Verified
Journal Article
Closed access
Ahmet YükselAhmet Yüksel
Ahmet Yüksel
MAMüslüm Arıcı
Müslüm Arıcı
MKMichal Krajčík
Michal Krajčík
MCMihriban Civan
Mihriban Civan
HKHasan Karabay
Hasan Karabay

1 January 2020 in Sustainable Cities and Society
Verified
Journal Article
Closed access
Ahmet YükselAhmet Yüksel
Ahmet Yüksel
Muslum AriciMuslum Arici
Muslum Arici
MKMichal Krajčík
Michal Krajčík
HKHasan Karabay
Hasan Karabay

11 March 2023 in Energy and Buildings
Verified
Journal Article
Closed access
Ahmet YükselAhmet Yüksel
Ahmet Yüksel
Muslum AriciMuslum Arici
Muslum Arici
MKMichal Krajčík
Michal Krajčík
MCMihriban Civan
Mihriban Civan
HKHasan Karabay
Hasan Karabay

26 July 2022 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
CTCüneyt Tunçkal
Cüneyt Tunçkal
Ahmet YükselAhmet Yüksel
Ahmet Yüksel
SCSalih Coşkun
Salih Coşkun
In this study, an air source heat pump drying system with an external condenser circuit connected in series was developed. The system was designed to enable the external condenser to be activated serially with the internal one via the solenoid valves controlled by the digital thermostat when the drying temperature of the cabinet reaches the desired level. Temperature control of the drying chamber was achieved by activating the external condenser along with the internal condenser. Exergy analysis was conducted for the process of drying banana slices via a closed-loop air source heat pump dryer (HPD) at various drying temperatures. Exergy efficiencies and losses for the HPD system were calculated. As a result, the exergy efficiency of the dryer was calculated to be between 75.93% and 80.95%, while the exergy efficiencies of the system and heat pump were found to range from 7 to 13.07%. Moreover, the expansion valve was found to have the highest exergy efficiency with 93.32%. The highest exergy losses were also found in the compressor and condenser with 0.557 kW and 0.366 kW, respectively.

2 September 2021 in Journal of Thermal Engineering
Verified
Journal Article
Closed access
PDF file
Ahmet YükselAhmet Yüksel
Ahmet Yüksel
Muslum AriciMuslum Arici
Muslum Arici
HKHasan Karabay
Hasan Karabay
The study aims to identify the main reason of the thermal response time difference between historical and modern buildings. Therefore, in this study, the thermal response time of historical and modern wall structures and its effect on the interior air temperature change was investigated parametrically. Considering the environmental conditions of Kocaeli province, Turkey, the thermal response time of a historical building wall made of a cut stone was compared with those of brick and gas concrete wall structures having the same overall heat transfer coefficient using the second-order lumped capacitance approach. The insulation thicknesses of the three different construction materials for U-values of 0.6, 0.4 and 0.2 W/m2K were calculated and temperature variations of indoor environment, wall and insulation material were analyzed. In addition, the required thicknesses of insulation material to obtain the same heat transfer coefficients were determined in case of using the 0.1 m thickness of cut stone, brick and gas concrete structure materials. The maximum and minimum amplitudes of the inside air temperature were recorded as 0.59 and 0.18oC for the aerated concrete in Case 3 and for the cut stone in Case 2, respectively. As a result, the walls with high thermal inertia are less affected by the changes in the environmental temperature although their U-value is relatively high. For this reason, it can be stated that one of the reasons why historical buildings have thick walls is to increase thermal inertia and thereby improve thermal comfort by reducing energy loss.