Akbar Teguh Prakoso

Prof. Akbar Teguh Prakoso

Sriwijaya University, Palembang, Sumatera Selatan, Indonesia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
HBHasan Basri
Hasan Basri
DADendy Adanta
Dendy Adanta
YRYulia Resti
Yulia Resti
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
TKTunku Kamarul
Tunku Kamarul
In designing porous scaffolds, permeability is essential to consider as a function of cell migration and bone tissue regeneration. Good permeability has been achieved by mimicking the complexity of natural cancellous bone. In this study, a porous scaffold was developed according to the morphological indices of cancellous bone (porosity, specific surface area, thickness, and tortuosity). The computational fluid dynamics method analyzes the fluid flow through the scaffold. The permeability values of natural cancellous bone and three types of scaffolds (cubic, octahedron pillar, and Schoen’s gyroid) were compared. The results showed that the permeability of the Negative Schwarz Primitive (NSP) scaffold model was similar to that of natural cancellous bone, which was in the range of 2.0 × 10−11 m2 to 4.0 × 10−10 m2. In addition, it was observed that the tortuosity parameter significantly affected the scaffold’s permeability and shear stress values. The tortuosity value of the NSP scaffold was in the range of 1.5–2.8. Therefore, tortuosity can be manipulated by changing the curvature of the surface scaffold radius to obtain a superior bone tissue engineering construction supporting cell migration and tissue regeneration. This parameter should be considered when making new scaffolds, such as our NSP. Such efforts will produce a scaffold architecturally and functionally close to the natural cancellous bone, as demonstrated in this study.

Verified
Journal Article
Open access
PDF file
JJJamari Jamari
Jamari Jamari
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
GSGatot Santoso
Gatot Santoso
S. SugihartoS. Sugiharto
S. Sugiharto
TSToto Supriyono
Toto Supriyono
EHEmile Van Der Heide
Emile Van Der Heide
Due to various concerns about the use of metal-on-metal that is detrimental to users, the use of metal as acetabular cup material was later changed to ultra high molecular weight polyethylene (UHMWPE). However, the wear on UHMWPE releases polyethylene wear particles, which can trigger a negative body response and contribute to osteolysis. For reducing the wear of polyethylene, one of the efforts is to investigate the selection of metal materials. Cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V) are the frequently employed materials. The computational evaluation of contact pressure was carried out using a two-dimensional axisymmetric model for UHMWPE acetabular cup paired with metal femoral head under gait cycle in this study. The results show Ti6Al4V-on-UHMWPE is able to reduce cumulative contact pressure compared to SS 316L-on-UHMWPE and CoCrMo-on-UHMWPE. Compared to Ti6Al4V-on-UHMWPE at peak loading, the difference in cumulative contact pressure to respective maximum contact pressure is 9.740% for SS 316L-on-UHMWPE and 11.038% for CoCrMo-on-UHMWPE.

3 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
RPRisky Utama Putra
Risky Utama Putra
HBHasan Basri
Hasan Basri
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
HCHendri Chandra
Hendri Chandra
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
TKTunku Kamarul
Tunku Kamarul
In the present study, the effects of human physiological activity levels on the fatigue life of a porous magnesium scaffold have been investigated. First, the dynamic immersion and biomechanical testing are carried out on a porous magnesium scaffold to simulate the physiological conditions. Then, a numerical data analysis and computer simulations predict the implant failure values. A 3D CAD bone scaffold model was used to predict the implant fatigue, based on the micro-tomographic images. This study uses a simulation of solid mechanics and fatigue, based on daily physiological activities, which include walking, running, and climbing stairs, with strains reaching 1000–3500 µm/mm. The porous magnesium scaffold with a porosity of 41% was put through immersion tests for 24, 48, and 72 h in a typical simulated body fluid. Longer immersion times resulted in increased fatigue, with cycles of failure (Nf) observed to decrease from 4.508 × 1022 to 2.286 × 1011 (1.9 × 1011 fold decrease) after 72 hours of immersion with a loading rate of 1000 µm/mm. Activities played an essential role in the rate of implant fatigue, such as demonstrated by the 1.1 × 105 fold increase in the Nf of walking versus stair climbing at 7.603 × 1011 versus 6.858 × 105, respectively. The dynamic immersion tests could establish data on activity levels when an implant fails over time. This information could provide a basis for more robust future implant designs.

3 January 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
ASAmir Putra Md Saad
Amir Putra Md Saad
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
MSM. A. Sulong
M. A. Sulong
HBHasan Basri
Hasan Basri
DWDian Agustin Wahjuningrum
Dian Agustin Wahjuningrum
ASArdiyansyah Syahrom
Ardiyansyah Syahrom

1 April 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
HBHasan Basri
Hasan Basri
ASA. Syahrom
A. Syahrom
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
DWD. Wicaksono
D. Wicaksono
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
RNR. D. Nugraha
R. D. Nugraha
This research analyzed the effect of applied surface texturing on bearing component of the artificial hip joint due to lubrication performance. The main contribution of the paper was explaining the significant role of adding dimples in artificial hip joint surface bearing who can probably decrease friction interaction on the acetabular liner and femoral head that impact on improving wear resistance. This is achieved by analyzing the geometric variation (shape and diameter) of the dimple to the performance of lubricating metal-on-metal artificial hip joint bearings under normal walking conditions. The research method focused on numerical analysis using the Fluid-Structure Interaction (FSI) simulation method which reviewed the solid and fluid structure. From the simulation results, it can be seen that the variation of ellipse dimple with a diameter of 80 μm has the best lubrication performance, which is indicated by the largest hydrodynamic fluid pressure of 0.915 Pa, the smallest solid pressure is 0.433 Pa, and the largest lubricant thickness is 22.672 μm.

1 September 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
HBHasan Basri
Hasan Basri
ASA Syahrom
A Syahrom
TRT S Ramadhoni
T S Ramadhoni
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
VIVincent
Vincent
Artificial hip joint surgery is one of the most successful methods used to restore the functioning of damaged hip bones. But there are obstacles to the use of artificial hip bone, which is the amount of friction occurring and wears. To overcome these obstacles, a surface of the artificial hip joint is modified by adding dimples in order to minimize the contact pressure of solid and to reduce friction and wear. The purpose of this study is to determine a better of lubrication performance with the variations of the dimple arrangements under the normal walking condition. Simulation results have already exited the point of convergence studies, and the obtained results are such as hydrodynamic pressure, contact pressure, and the film thickness of the lubricant with the variations of the number and pitch dimples. The results of the CSM method under dry condition, it shows that the addition of surface with dimples has a positive effect to reduce the contact pressure and indirectly reduce wear. The maximum surface contact pressure is 54.84 MPa with dimple and 94.22 MPa without a dimple. The results of the FSI method under lubrication condition, it was found that the variation of 7 dimples with a dimple pitch of 500 μm has the best lubrication performance. The hydrodynamic pressure is 0.73 Pa, the contact pressure is 0.42 Pa, and the film thickness of the lubricant is 29.59 μm. The increase of film thickness that occurs due to hydrodynamic pressure will cause the fluid lift force to withstand the loading of the solid structure.