Hasan Basri

Prof. Dr. Hasan Basri

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
IAILHAM YUSTAR AFIF
ILHAM YUSTAR AFIF
MMMohamad Izzur Maula
Mohamad Izzur Maula
TWTri Indah Winarni
Tri Indah Winarni
MTMohammad Tauviqirrahman
Mohammad Tauviqirrahman
JJJamari Jamari
Jamari Jamari
The selection of biomaterials for bearing in total hip arthroplasty is very important to avoid various risks of primary postoperative failure for patients. The current investigation attempts to analyze the Tresca stress of metal-on-metal bearings with three different materials, namely, cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V). We used computational simulations using a 2D axisymmetric finite element model to predict Tresca stresses under physiological conditions of the human hip joint during normal walking. The simulation results show that Ti6Al4V-on-Ti6Al4V has the best performance to reduce Tresca stress by 45.76% and 39.15%, respectively, compared to CoCrMo-on-CoCrMo and SS 316L-on-SS 316L.

1 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
HBHasan Basri
Hasan Basri
DADendy Adanta
Dendy Adanta
YRYulia Resti
Yulia Resti
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
TKTunku Kamarul
Tunku Kamarul
In designing porous scaffolds, permeability is essential to consider as a function of cell migration and bone tissue regeneration. Good permeability has been achieved by mimicking the complexity of natural cancellous bone. In this study, a porous scaffold was developed according to the morphological indices of cancellous bone (porosity, specific surface area, thickness, and tortuosity). The computational fluid dynamics method analyzes the fluid flow through the scaffold. The permeability values of natural cancellous bone and three types of scaffolds (cubic, octahedron pillar, and Schoen’s gyroid) were compared. The results showed that the permeability of the Negative Schwarz Primitive (NSP) scaffold model was similar to that of natural cancellous bone, which was in the range of 2.0 × 10−11 m2 to 4.0 × 10−10 m2. In addition, it was observed that the tortuosity parameter significantly affected the scaffold’s permeability and shear stress values. The tortuosity value of the NSP scaffold was in the range of 1.5–2.8. Therefore, tortuosity can be manipulated by changing the curvature of the surface scaffold radius to obtain a superior bone tissue engineering construction supporting cell migration and tissue regeneration. This parameter should be considered when making new scaffolds, such as our NSP. Such efforts will produce a scaffold architecturally and functionally close to the natural cancellous bone, as demonstrated in this study.

Verified
Journal Article
Open access
PDF file
JJJamari Jamari
Jamari Jamari
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
ASAmir Putra Md Saad
Amir Putra Md Saad
ASArdiyansyah Syahrom
Ardiyansyah Syahrom
Mohammad UddinMohammad Uddin
Mohammad Uddin
HBHasan Basri
Hasan Basri
Wear and wear-induced debris is a significant factor in causing failure in implants. Reducing contact pressure by using a textured surface between the femoral head and acetabular cup is crucial to improving the implant’s life. This study presented the effect of surface texturing as dimples on the wear evolution of total hip arthroplasty. It was implemented by developing finite element analysis from the prediction model without dimples and with bottom profile dimples of flat, drill, and ball types. Simulations were carried out by performing 3D physiological loading of the hip joint under normal walking conditions. A geometry update was initiated based on the patient’s daily routine activities. Our results showed that the addition of dimples reduced contact pressure and wear. The bottom profile dimples of the ball type had the best ability to reduce wear relative to the other types, reducing cumulative linear wear by 24.3% and cumulative volumetric wear by 31% compared to no dimples. The findings demonstrated that surface texturing with appropriate dimple bottom geometry on a bearing surface is able to extend the lifetime of hip implants.

Verified
Journal Article
Open access
PDF file
JJJamari Jamari
Jamari Jamari
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
GSGatot Santoso
Gatot Santoso
S. SugihartoS. Sugiharto
S. Sugiharto
TSToto Supriyono
Toto Supriyono
EHEmile Van Der Heide
Emile Van Der Heide
Due to various concerns about the use of metal-on-metal that is detrimental to users, the use of metal as acetabular cup material was later changed to ultra high molecular weight polyethylene (UHMWPE). However, the wear on UHMWPE releases polyethylene wear particles, which can trigger a negative body response and contribute to osteolysis. For reducing the wear of polyethylene, one of the efforts is to investigate the selection of metal materials. Cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V) are the frequently employed materials. The computational evaluation of contact pressure was carried out using a two-dimensional axisymmetric model for UHMWPE acetabular cup paired with metal femoral head under gait cycle in this study. The results show Ti6Al4V-on-UHMWPE is able to reduce cumulative contact pressure compared to SS 316L-on-UHMWPE and CoCrMo-on-UHMWPE. Compared to Ti6Al4V-on-UHMWPE at peak loading, the difference in cumulative contact pressure to respective maximum contact pressure is 9.740% for SS 316L-on-UHMWPE and 11.038% for CoCrMo-on-UHMWPE.

3 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
RPRisky Utama Putra
Risky Utama Putra
HBHasan Basri
Hasan Basri
APAkbar Teguh Prakoso
Akbar Teguh Prakoso
HCHendri Chandra
Hendri Chandra
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
TKTunku Kamarul
Tunku Kamarul
In the present study, the effects of human physiological activity levels on the fatigue life of a porous magnesium scaffold have been investigated. First, the dynamic immersion and biomechanical testing are carried out on a porous magnesium scaffold to simulate the physiological conditions. Then, a numerical data analysis and computer simulations predict the implant failure values. A 3D CAD bone scaffold model was used to predict the implant fatigue, based on the micro-tomographic images. This study uses a simulation of solid mechanics and fatigue, based on daily physiological activities, which include walking, running, and climbing stairs, with strains reaching 1000–3500 µm/mm. The porous magnesium scaffold with a porosity of 41% was put through immersion tests for 24, 48, and 72 h in a typical simulated body fluid. Longer immersion times resulted in increased fatigue, with cycles of failure (Nf) observed to decrease from 4.508 × 1022 to 2.286 × 1011 (1.9 × 1011 fold decrease) after 72 hours of immersion with a loading rate of 1000 µm/mm. Activities played an essential role in the rate of implant fatigue, such as demonstrated by the 1.1 × 105 fold increase in the Nf of walking versus stair climbing at 7.603 × 1011 versus 6.858 × 105, respectively. The dynamic immersion tests could establish data on activity levels when an implant fails over time. This information could provide a basis for more robust future implant designs.

1 May 2017 in Materials & Design
Verified
Journal Article
Closed access
ASAmir Putra Md Saad
Amir Putra Md Saad
RRRabiatul Adibah Abdul Rahim
Rabiatul Adibah Abdul Rahim
MHMuhamad Noor Harun
Muhamad Noor Harun
HBHasan Basri
Hasan Basri
JAJaafar Abdullah
Jaafar Abdullah
ASArdiyansyah Syahrom
Ardiyansyah Syahrom