Andrea Persons

Dr. Andrea Persons

Mississippi State University
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
APAndrea Persons
Andrea Persons
John BallJohn Ball
John Ball
CFCharles Freeman
Charles Freeman
DMDavid M. Macias
David M. Macias
CSC. LaShan Simpson
C. LaShan Simpson
Reuben BurchReuben Burch
Reuben Burch
Standards for the fatigue testing of wearable sensing technologies are lacking. The majority of published fatigue tests for wearable sensors are performed on proof-of-concept stretch sensors fabricated from a variety of materials. Due to their flexibility and stretchability, polymers are often used in the fabrication of wearable sensors. Other materials, including textiles, carbon nanotubes, graphene, and conductive metals or inks, may be used in conjunction with polymers to fabricate wearable sensors. Depending on the combination of the materials used, the fatigue behaviors of wearable sensors can vary. Additionally, fatigue testing methodologies for the sensors also vary, with most tests focusing only on the low-cycle fatigue (LCF) regime, and few sensors are cycled until failure or runout are achieved. Fatigue life predictions of wearable sensors are also lacking. These issues make direct comparisons of wearable sensors difficult. To facilitate direct comparisons of wearable sensors and to move proof-of-concept sensors from “bench to bedside”, fatigue testing standards should be established. Further, both high-cycle fatigue (HCF) and failure data are needed to determine the appropriateness in the use, modification, development, and validation of fatigue life prediction models and to further the understanding of how cracks initiate and propagate in wearable sensing technologies.

7 September 2020 in Electronics
Verified
Journal Article
Open access
PDF file
PTPurva Talegaonkar
Purva Talegaonkar
DSDavid Saucier
David Saucier
WCWill Carroll
Will Carroll
PPPreston Peranich
Preston Peranich
EPErin Parker
Erin Parker
RPR. K. Prabhu
R. K. Prabhu
This paper presents a retrospective of the benchmark testing methodologies developed and accumulated into the stretch sensor tool kit (SSTK) by the research team during the Closing the Wearable Gap series of studies. The techniques developed to validate stretchable soft robotic sensors (SRS) as a means for collecting human kinetic and kinematic data at the foot-ankle complex and at the wrist are reviewed. Lessons learned from past experiments are addressed, as well as what comprises the current SSTK based on what the researchers learned over the course of multiple studies. Three core components of the SSTK are featured: (a) material testing tools, (b) data analysis software, and (c) data collection devices. Results collected indicate that the stretch sensors are a viable means for predicting kinematic data based on the most recent gait analysis study conducted by the researchers (average root mean squared error or RMSE = 3.63°). With the aid of SSTK defined in this study summary and shared with the academic community on GitHub, researchers will be able to undergo more rigorous validation methodologies of SRS validation. A summary of the current state of the SSTK is detailed and includes insight into upcoming experiments that will utilize more sophisticated techniques for fatigue testing and gait analysis, utilizing SRS as the data collection solution.

19 January 2023 in ECS Sensors Plus
Verified
Journal Article
Open access
APAndrea Persons
Andrea Persons
CMCarver Middleton
Carver Middleton
EPErin Parker
Erin Parker
JBJohn E. Ball
John E. Ball
RVReuben F. Burch V.
Reuben F. Burch V.
SESteven H. Elder
Steven H. Elder
Wearable stretch sensors have potential applications across many fields including medicine and sports, but the accuracy of the data produced by the sensors over repeated uses is largely unknown due to a paucity of high-cycle fatigue (HCF) studies on both the materials comprising the sensors and the signal produced by the sensors. To overcome these limitations, using human physiologically-based parameters, stretch sensors were subjected to quasi-static testing and HCF with simultaneous capture of the signal. The strain produced by the sensor was then compared to the strain produced by testing instrument, and the results suggest that the output from the stretch sensors is strongly correlated with output from the testing instrument under quasi-static conditions; however, this correlation deteriorates under fatigue conditions. Such deterioration may be the result of several factors, including a mismatch between the material response to fatiguing and the signal response to fatiguing. From a materials perspective, the shape of the stress-life curve for the polymers comprising the sensors conforms to the Rabinowitz-Beardmore model of polymer fatigue. Based on these results, consideration of the material properties of a stretch sensor are necessary to determine how accurate the output from the sensor will be for a given application.

1 October 2021 in International Journal of Fatigue
Verified
Journal Article
Closed access
MCM.S. Cagle
M.S. Cagle
KBK.E. Bryan
K.E. Bryan
MDMatthew Dantin
Matthew Dantin
WFW.M. Furr
W.M. Furr
DGDeepesh Giri
Deepesh Giri
MHM.F. Horstemeyer
M.F. Horstemeyer

15 September 2024 in Biology Open
Verified
Journal Article
Open access
APAndrea Persons
Andrea Persons
YHYoussef Hammi
Youssef Hammi
SESteve Elder
Steve Elder
LPLauren B. Priddy
Lauren B. Priddy
MPMatthew W. Priddy
Matthew W. Priddy
M. F. HorstemeyerM. F. Horstemeyer
M. F. Horstemeyer
North American bison (Bovidae: Bison bison) incur blunt impacts to the interparietal and frontal bones when they engage in head-to-head fights. To investigate the impact mitigation of these bones, a finite element analysis (FEA) of the skull under loading conditions was performed. Based on anatomical and histological studies, the interparietal and frontal bones are both comprised of a combination of haversian and plexiform bone and are both underlain by bony septa. Additionally, the interparietal bone is thicker than the frontal bone. Data regarding the mechanical properties of bison bone are scarce, but the results of a phylogenetic analysis infer that the material properties of the closely related domestic cow bone are a suitable proxy for use in the FEA. Results of the FEA suggest that the thickness of the interparietal bone in conjunction with the bony septa may prevent fracture stresses by helping to absorb and disperse the blunt impact energy throughout the skull. Monotonic stress levels of 294 MPa, which are below the compressive strength of bone were exhibited in the simulated bison head impacts indicating no fracture of the bones.

25 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
APAndrea Persons
Andrea Persons
CMCarver Middleton
Carver Middleton
EPErin Parker
Erin Parker
WCWill Carroll
Will Carroll
ATAlana Turner
Alana Turner
Reuben BurchReuben Burch
Reuben Burch
Motion capture is the current gold standard for assessing movement of the human body, but laboratory settings do not always mimic the natural terrains and movements encountered by humans. To overcome such limitations, a smart sock that is equipped with stretch sensors is being developed to record movement data outside of the laboratory. For the smart sock stretch sensors to provide valuable feedback, the sensors should have durability of both materials and signal. To test the durability of the stretch sensors, the sensors were exposed to high-cycle fatigue testing with simultaneous capture of the capacitance. Following randomization, either the fatigued sensor or an unfatigued sensor was placed in the plantarflexion position on the smart sock, and participants were asked to complete the following static movements: dorsiflexion, inversion, eversion, and plantarflexion. Participants were then asked to complete gait trials. The sensor was then exchanged for either an unfatigued or fatigued plantarflexion sensor, depending upon which sensor the trials began with, and each trial was repeated by the participant using the opposite sensor. Results of the tests show that for both the static and dynamic movements, the capacitive output of the fatigued sensor was consistently higher than that of the unfatigued sensor suggesting that an upwards drift of the capacitance was occurring in the fatigued sensors. More research is needed to determine whether stretch sensors should be pre-stretched prior to data collection, and to also determine whether the drift stabilizes once the cyclic softening of the materials comprising the sensor has stabilized.