Alana Turner

Alana Turner


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Harish ChanderHarish Chander
Harish Chander
Reuben BurchReuben Burch
Reuben Burch
PTPurva Talegaonkar
Purva Talegaonkar
DSDavid Saucier
David Saucier
Anthony LuczakAnthony Luczak
Anthony Luczak
RPRaj Prabhu
Raj Prabhu
Wearable sensors are beneficial for continuous health monitoring, movement analysis, rehabilitation, evaluation of human performance, and for fall detection. Wearable stretch sensors are increasingly being used for human movement monitoring. Additionally, falls are one of the leading causes of both fatal and nonfatal injuries in the workplace. The use of wearable technology in the workplace could be a successful solution for human movement monitoring and fall detection, especially for high fall-risk occupations. This paper provides an in-depth review of different wearable stretch sensors and summarizes the need for wearable technology in the field of ergonomics and the current wearable devices used for fall detection. Additionally, the paper proposes the use of soft-robotic-stretch (SRS) sensors for human movement monitoring and fall detection. This paper also recapitulates the findings of a series of five published manuscripts from ongoing research that are published as Parts I to V of “Closing the Wearable Gap” journal articles that discuss the design and development of a foot and ankle wearable device using SRS sensors that can be used for fall detection. The use of SRS sensors in fall detection, its current limitations, and challenges for adoption in human factors and ergonomics are also discussed.

12 November 2019 in Behavioral Sciences
Verified
Journal Article
Open access
PDF file
Harish ChanderHarish Chander
Harish Chander
Sachini Kodithuwakku ArachchigeSachini Kodithuwakku Arachchige
Sachini Kodithuwakku Arachchige
CHChris Hill
Chris Hill
ATAlana Turner
Alana Turner
SDShuchisnigdha Deb
Shuchisnigdha Deb
Daniel CarruthDaniel Carruth
Daniel Carruth
Background: Virtual reality (VR) is becoming a widespread tool in rehabilitation, especially for postural stability. However, the impact of using VR in a “moving wall paradigm” (visual perturbation), specifically without and with anticipation of the perturbation, is unknown. Methods: Nineteen healthy subjects performed three trials of static balance testing on a force plate under three different conditions: baseline (no perturbation), unexpected VR perturbation, and expected VR perturbation. The statistical analysis consisted of a 1 × 3 repeated-measures ANOVA to test for differences in the center of pressure (COP) displacement, 95% ellipsoid area, and COP sway velocity. Results: The expected perturbation rendered significantly lower (p < 0.05) COP displacements and 95% ellipsoid area compared to the unexpected condition. A significantly higher (p < 0.05) sway velocity was also observed in the expected condition compared to the unexpected condition. Conclusions: Postural stability was lowered during unexpected visual perturbations compared to both during baseline and during expected visual perturbations, suggesting that conflicting visual feedback induced postural instability due to compensatory postural responses. However, during expected visual perturbations, significantly lowered postural sway displacement and area were achieved by increasing the sway velocity, suggesting the occurrence of postural behavior due to anticipatory postural responses. Finally, the study also concluded that VR could be used to induce different postural responses by providing visual perturbations to the postural control system, which can subsequently be used as an effective and low-cost tool for postural stability training and rehabilitation.

12 May 2020 in Electronics
Verified
Journal Article
Open access
PDF file
SDSamaneh Davarzani
Samaneh Davarzani
DSDavid Saucier
David Saucier
PPPreston Peranich
Preston Peranich
WCWill Carroll
Will Carroll
ATAlana Turner
Alana Turner
Anthony LuczakAnthony Luczak
Anthony Luczak
A novel wearable solution using soft robotic sensors (SRS) has been investigated to model foot-ankle kinematics during gait cycles. The capacitance of SRS related to foot-ankle basic movements was quantified during the gait movements of 20 participants on a flat surface as well as a cross-sloped surface. In order to evaluate the power of SRS in modeling foot-ankle kinematics, three-dimensional (3D) motion capture data was also collected for analyzing gait movement. Three different approaches were employed to quantify the relationship between the SRS and the 3D motion capture system, including multivariable linear regression, an artificial neural network (ANN), and a time-series long short-term memory (LSTM) network. Models were compared based on the root mean squared error (RMSE) of the prediction of the joint angle of the foot in the sagittal and frontal plane, collected from the motion capture system. There was not a significant difference between the error rates of the three different models. The ANN resulted in an average RMSE of 3.63, being slightly more successful in comparison to the average RMSE values of 3.94 and 3.98 resulting from multivariable linear regression and LSTM, respectively. The low error rate of the models revealed the high performance of SRS in capturing foot-ankle kinematics during the human gait cycle.

18 October 2018 in Geriatrics
Verified
Journal Article
Open access
PDF file
ATAlana Turner
Alana Turner
Harish ChanderHarish Chander
Harish Chander
AKAdam Knight
Adam Knight
Falls and fall-related injuries are a serious health concern in geriatric populations, especially with age-related deficits in postural control and during postural control challenging dual-task situations. Balance training has been reported to be beneficial in reducing falls. However, some of these exercises have their inherent physical challenges that prevent the elderly population from performing them effectively. Other concomitant age-related illness in the elderly pose further challenges in performing these exercises. Hence, the topic of finding alternative types of balance training that are effective and are performed in a safer environment is constantly researched. One such alternative is hydrotherapy that focuses on balance and postural perturbation-based exercises in water-based environments such as aquatic swimming pools or in dedicated hydrotherapy pools. Hydrotherapy for geriatric populations has been reported to be beneficial in improving balance, motor and cognitive tasks with improved motivation and positive attitude towards exercises. Additionally, hydrotherapy also has properties of buoyancy, resistance and temperature, which benefit biomechanical and physiological wellness and offers a safe environment to perform balance training. Hydrotherapy balance training need to be scaled and prescribed according to individual needs and can serve as an effective training and rehabilitation protocol in reducing falls in geriatric population.

21 November 2019 in Electronics
Verified
Journal Article
Open access
PDF file
DSDavid Saucier
David Saucier
SDSamaneh Davarzani
Samaneh Davarzani
ATAlana Turner
Alana Turner
Anthony LuczakAnthony Luczak
Anthony Luczak
PNPhuoc Nguyen
Phuoc Nguyen
RPRaj Prabhu
Raj Prabhu
The purpose of this study was to use 3D motion capture and stretchable soft robotic sensors (SRS) to collect foot-ankle movement on participants performing walking gait cycles on flat and sloped surfaces. The primary aim was to assess differences between 3D motion capture and a new SRS-based wearable solution. Given the complex nature of using a linear solution to accurately quantify the movement of triaxial joints during a dynamic gait movement, 20 participants performing multiple walking trials were measured. The participant gait data was then upscaled (for the SRS), time-aligned (based on right heel strikes), and smoothed using filtering methods. A multivariate linear model was developed to assess goodness-of-fit based on mean absolute error (MAE; 1.54), root mean square error (RMSE; 1.96), and absolute R2 (R2; 0.854). Two and three SRS combinations were evaluated to determine if similar fit scores could be achieved using fewer sensors. Inversion (based on MAE and RMSE) and plantar flexion (based on R2) sensor removal provided second-best fit scores. Given that the scores indicate a high level of fit, with further development, an SRS-based wearable solution has the potential to measure motion during gait- based tasks with the accuracy of a 3D motion capture system.

7 September 2020 in Electronics
Verified
Journal Article
Open access
PDF file
PTPurva Talegaonkar
Purva Talegaonkar
DSDavid Saucier
David Saucier
WCWill Carroll
Will Carroll
PPPreston Peranich
Preston Peranich
EPErin Parker
Erin Parker
RPR. K. Prabhu
R. K. Prabhu
This paper presents a retrospective of the benchmark testing methodologies developed and accumulated into the stretch sensor tool kit (SSTK) by the research team during the Closing the Wearable Gap series of studies. The techniques developed to validate stretchable soft robotic sensors (SRS) as a means for collecting human kinetic and kinematic data at the foot-ankle complex and at the wrist are reviewed. Lessons learned from past experiments are addressed, as well as what comprises the current SSTK based on what the researchers learned over the course of multiple studies. Three core components of the SSTK are featured: (a) material testing tools, (b) data analysis software, and (c) data collection devices. Results collected indicate that the stretch sensors are a viable means for predicting kinematic data based on the most recent gait analysis study conducted by the researchers (average root mean squared error or RMSE = 3.63°). With the aid of SSTK defined in this study summary and shared with the academic community on GitHub, researchers will be able to undergo more rigorous validation methodologies of SRS validation. A summary of the current state of the SSTK is detailed and includes insight into upcoming experiments that will utilize more sophisticated techniques for fatigue testing and gait analysis, utilizing SRS as the data collection solution.