Elena Bardi

Dr. Elena Bardi

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2025 in Medicina
Verified
Journal Article
Open access
PDF file
LBLuca Bertolino
Luca Bertolino
MRMarta Bianca Maria Ranzini
Marta Bianca Maria Ranzini
AFALBERTO FAVARO
ALBERTO FAVARO
EBElena Bardi
Elena Bardi
FRFlavio Lorenzo Ronzoni
Flavio Lorenzo Ronzoni
TBTommaso Bonanzinga
Tommaso Bonanzinga
Background and Objectives: This scoping review explores the current state of the art of AI-based applications in the field of orthopedics, focusing on its implementation in diagnostic imaging and preoperative planning of knee joint procedures. Materials and Methods: The search was carried out using the recognized scholarly databases PubMed, Medline and Embase and was set to identify original research addressing AI applied to imaging in knee diagnosis and surgical planning, written in English and published up to January 2025. Results: The search produced 1612 papers, of which 36 were included in our review. All papers addressed AI applied to common imaging methods in clinical practice. Of these, thirty integrated AI-based tools with X-rays, one applied AI to X-rays to produce CT-like 3D reproductions, and two studies applied AI to MRI. Conclusions: Several AI tools have already been validated for enhancing the accuracy of measurements and detecting additional parameters in a shorter time compared to standard assessments. We expect these may soon be introduced into routine clinical practice to streamline a number of technical tasks and in some cases to replace the need for human intervention.

10 December 2024 in Wearable Technologies
Verified
Journal Article
Open access
PDF file
EBElena Bardi
Elena Bardi
AEAdrian Esser
Adrian Esser
PWPeter Wolf
Peter Wolf
MGMarta Gandolla
Marta Gandolla
EAEmilia Ambrosini
Emilia Ambrosini
RRRobert Riener
Robert Riener
Cable-driven exosuits have the potential to support individuals with motor disabilities across the continuum of care. When supporting a limb with a cable, force sensors are often used to measure tension. However, force sensors add cost, complexity, and distal components. This paper presents a design and control approach to remove the force sensor from an upper limb cable-driven exosuit. A mechanical design for the exosuit was developed to maximize passive transparency. Then, a data-driven friction identification was conducted on a mannequin test bench to design a model-based tension controller. Seventeen healthy participants raised and lowered their right arms to evaluate tension tracking, movement quality, and muscular effort. Questionnaires on discomfort, physical exertion, and fatigue were collected. The proposed strategy allowed tracking the desired assistive torque with a root mean square error of 0.71 Nm (18%) at 50% gravity support. During the raising phase, the electromyography signals of the anterior deltoid, trapezius, and pectoralis major were reduced on average compared to the no-suit condition by 30, 38, and 38%, respectively. The posterior deltoid activity was increased by 32% during lowering. Position tracking was not significantly altered, whereas movement smoothness significantly decreased. This work demonstrates the feasibility and effectiveness of removing the force sensor from a cable-driven exosuit. A significant increase in discomfort in the lower neck and right shoulder indicated that the ergonomics of the suit could be improved. Overall this work paves the way toward simpler and more affordable exosuits.

Verified
Journal Article
Open access
PDF file
EBElena Bardi
Elena Bardi
DDDaniele D'Arrigo
Daniele D'Arrigo
CPChiara Pozzi
Chiara Pozzi
AGAndrea Maria Gatti
Andrea Maria Gatti
LBLuca Bertolino
Luca Bertolino
TBTommaso Bonanzinga
Tommaso Bonanzinga
Evidence suggests that a cross-talk between the gut microbiota and joint health exists in a paradigm known as the gut–joint axis. Recent studies have also reported the presence of microorganisms potentially involved in the pathogenesis and progression of arthritis in synovial joints, previously believed to be sterile. This systematic review describes in detail the methodologies employed to characterize the microbiota in human synovial fluid (SF). A literature search was conducted in PubMed, Embase, and Web of Science up to 5 February 2025. Nine studies aimed to characterize the SF microbiome using next-generation sequencing or polymerase chain reaction. Eight studies detected bacterial DNA in SF. However, significant heterogeneity and incomplete reporting in methodologies, including sample collection and preparation, contamination management, DNA extraction and amplification, sequencing technology, targeted 16S rRNA or ITS regions, and bioinformatics processing, limit the comparability and significance of findings. Given the potential implications for understanding arthritis mechanisms and developing targeted treatments, a standardized methodological and reporting approach in SF microbiota characterization is needed to enhance the reproducibility and the relevance of results.

26 August 2026 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
GAGregorio Alberto
Gregorio Alberto
YSYazan Abu Salem
Yazan Abu Salem
EBElena Bardi
Elena Bardi
AFALBERTO FAVARO
ALBERTO FAVARO
TBTommaso Bonanzinga
Tommaso Bonanzinga
Return to sports (RTS) has become an increasingly common expectation for patients undergoing total or unicompartmental knee arthroplasty (TKA and UKA), par

29 August 2025 in Medicina
Verified
Journal Article
Open access
PDF file
GPGianluca Piovan
Gianluca Piovan
AAAndrea Amarossi
Andrea Amarossi
LBLuca Bertolino
Luca Bertolino
EBElena Bardi
Elena Bardi
AFALBERTO FAVARO
ALBERTO FAVARO
TBTommaso Bonanzinga
Tommaso Bonanzinga
Background and objectives: Patient-specific components (PSC) represent an innovative option for total knee arthroplasty (TKA) in advanced osteoarthritis. Their effectiveness, however, closely relies on accurate positioning. Our study investigates the accuracy achieved by means of an inertial-based extramedullary cutting guide and the postoperative clinical and radiographic outcomes. Methods and materials: This was a prospective, single-arm, pilot study involving patients undergoing primary TKA with YourKneeTM PSC. Femoral and tibial bone resections were performed using the Perseus inertial-based extramedullary cutting guide. Postoperative mechanical alignment and component positioning were assessed by computed tomography. Clinical outcomes were evaluated preoperatively and at 1, 3, 6, and 12 months postoperatively by main knee function and clinical outcome measures. Results: The study population included a small cohort (n= 12, four females/eight males, mean age 69 ± 5.65 years, mean BMI 25.7 ± 3.8 kg/m2, KL grade > 3) with no control group. The mean absolute error between the planned and obtained Hip–Knee–Ankle angle was 1.36° ± 1.06 and within ±3° of all cases. Mean coronal alignment error was 1.87° ± 0.87 and 1.67° ± 0.75 for the femoral and tibial components, respectively. The mean sagittal alignment error was 1.89° ± 1.24 and 2.45° ± 0.87 for the femoral and the tibial components, respectively. Patients showed significant improvement in clinical and functional scores within the first 6 months: OKS increased from 20.64 ± 2.77 at the preoperative screening to 42.27 ± 4.34 (p < 0.0001), total KSS rose from 90.64 ± 17.25 to 169.36 ± 23.57 (p < 0.0001), and FJS reached 85.09 ± 17.14 at 6 months (p = 0.0031), indicating excellent functional recovery and forgotten joint effect. Knee ROM improved from 90.91° ± 11.14 to 110.36° ± 8.44 (p < 0.0001). After 6 months, outcome scores plateaued, suggesting an early stabilization of clinical benefits. No signs of radiolucency were detected on X-rays at 3- and 12-month follow-ups. Conclusions: The Perseus inertial-based extramedullary cutting guide used in combination with the YourKneeTM PSCs resulted in accurate intraoperative prosthesis positioning and significant improvements in clinical and functional outcomes at 6 months after surgery. Despite the small sample size and absence of a control group, the results suggest that such combination represents a viable option to conventional surgical instrumentation and current off-the-shelf prosthetic designs.