The feasibility and efficiency of a seismic retrofit intervention using externally bonded fiber-reinforced polymer composites on existing reinforced concrete frame systems, designed prior to the introduction of modern standard seismic design code provisions in the mid-1970s, are herein presented, based on analytical and experimental investigations on beam-column joint subassemblies and frame systems. A multilevel retrofit strategy, following hierarchy of strength considerations, is adopted to achieve the desired performance. The expected sequence of events is visualized through capacity-demand curves within performance domains. An analytical procedure able to predict the enhanced nonlinear behavior of the panel zone region, due to the application of CFRP laminates, in terms of shear strength (principal stresses) versus shear deformation, has been developed and is herein proposed as a fundamental step for the definition of a proper retrofit solution. The experimental results from quasi-static tests on beam-column subassemblies, either interior and exterior, and on three-storey three-bay frame systems in their as-built and CFRP retrofitted configurations, provided very satisfactory confirmation of the viability and reliability of the adopted retrofit solution as well as of the proposed analytical procedure to predict the actual sequence of events.
This paper investigates the effectiveness of carbon fiber spike anchors as a means of anchoring externally bonded (EB) fiber-reinforced polymers (FRP) and textile reinforced mortar (TRM) sheets into concrete. The investigation employs experimental work, which includes reinforced concrete (RC) columns strengthened with various configurations of EB FRP and TRM sheets connected to RC footings via carbon fiber spike anchors. The fiber spikes have two parts: the anchor part and the fan part. The anchor part is a bar-type dowel component that is epoxy pre-impregnated and inserted into epoxy filled holes within the footing. The fan part was impregnated in-situ and fanned out over and bonded to the EB reinforcement of the column. The connections were tested by pulling the columns upwards, thus applying tensile forces to the connection system. The direct tensile capacity of the anchors was determined for a number of vari- ables including the size and number of anchors, the bonding agent and the type and amount of EB rein- forcement. It is concluded that, with appropriate anchorage into concrete, the carbon fiber spike anchor is an effective anchorage system, and therefore, could be used in a range of strengthening applications to prevent premature delamination of FRP and TRM sheets from concrete surfaces
1 December 2005 in Bulletin of Earthquake Engineering
This article presents a summary of the experimental dynamic response of curved surface sliders as resulting from more than 1000 dynamic tests on about 60 different types of devices performed at the laboratory of the EUCENTRE foundation. Two different kinds of low-friction sliding materials have been employed in the devices, derived from polyamide (PA), or polyethylene (PE) materials. The rate of change of the dynamic friction coefficient as a function of sliding velocity and contact pressure is assessed and the transition phase between dynamic and static friction, with the consequent possible evidence of static/stick-slip phenomena, has been carefully considered.
About Me
Associate professor of Structural Engineering, Senior advisor of Foundation EUCENTRE
Associate professor of Structural Engineering, Senior advisor of Foundation EUCENTRE