Alessandro Marcio Hakme da Silva

Prof. Dr. Alessandro Marcio Hakme da Silva

orcid
Bioengineering and Biomechanics

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in International Journal of Nanomedicine
Verified
Journal Article
Open access
TSThiago Domingues Stocco
Thiago Domingues Stocco
TZTianyi Zhang
Tianyi Zhang
EDEdgar Dimitrov
Edgar Dimitrov
AGAnupama Ghosh
Anupama Ghosh
Alessandro Marcio Hakme da SilvaAlessandro Marcio Hakme da Silva
Alessandro Marcio Hakme da Silva
Anderson de Oliveira LoboAnderson de Oliveira Lobo
Anderson de Oliveira Lobo
Dove Press is a member of the Open Access Initiative, specializing in peer reviewed Medical Journals. View articlesor submit your research for publishing

12 January 2025 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MKMUHAMMAD USMAN Khalid
MUHAMMAD USMAN Khalid
ARAustėja Rudokaitė
Austėja Rudokaitė
Alessandro Marcio Hakme da SilvaAlessandro Marcio Hakme da Silva
Alessandro Marcio Hakme da Silva
MKMonika Kirsnytė-Šniokė
Monika Kirsnytė-Šniokė
Arunas StirkeArunas Stirke
Arunas Stirke
WMWanessa Melo
Wanessa Melo
Niobium nanoparticles (NbNPs) have gained attention as promising materials in biomedical applications due to their exceptional biocompatibility, corrosion resistance, and versatility. These nanoparticles offer potential in drug delivery, imaging, and tissue engineering, where their nanoscale properties allow precise interactions with biological systems. Among niobium-based nanomaterials, niobium pentoxide (Nb2O5) is the most extensively studied due to its chemical stability, bioactivity, and optical properties. Nb2O5 nanoparticles have shown significant potential in catalysis, biosensing, and photodynamic therapy, as their stability and reactivity make them ideal for functionalization in advanced biomedical applications. Despite these advantages, challenges remain regarding the biodegradability and long-term retention of NbNPs in biological systems. Their accumulation in tissues can lead to risks such as chronic inflammation or toxicity, emphasizing the importance of designing nanoparticles with controlled clearance and biodegradability. Surface modifications, such as coatings with biocompatible polymers, have demonstrated the ability to mitigate these risks while enhancing therapeutic efficacy. This review provides a comprehensive overview of NbNPs, with a focus on Nb2O5, highlighting their unique properties, current biomedical applications, and limitations. By addressing the remaining challenges, this work aims to guide the development of safer and more effective niobium-based nanomaterials for future medical innovations.

1 June 2014 in Research on Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Alessandro Marcio Hakme da SilvaAlessandro Marcio Hakme da Silva
Alessandro Marcio Hakme da Silva
JAJosé Marcos Alves
José Marcos Alves
OSOrivaldo Lopes da Silva
Orivaldo Lopes da Silva
NJNelson Silva Jr.
Nelson Silva Jr.
INTRODUCTION: Trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. METHODS: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freezed at - 20 °C before carrying out the microCT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). RESULTS: The Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transverserly isotropic symmetry. DISCUSSION: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (∝CT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases.

1 January 2013 in Procedia Engineering
Verified
Journal Article
Open access
RCR. Cesar
R. Cesar
RBR.S. Boffa
R.S. Boffa
LFL.T. Fachine
L.T. Fachine
TLT.P. Leivas
T.P. Leivas
Alessandro Marcio Hakme da SilvaAlessandro Marcio Hakme da Silva
Alessandro Marcio Hakme da Silva
JRJ.M.D.A. Rollo
J.M.D.A. Rollo
Osteoporosis is defined by the National Institutes of Health as a skeletal disorder characterized by compromised bone strength, increasing fracture risk. Samples of vertebral cancellous bone were extracted from human cadavers from the T12 region. The comparative pre-selection of bone into the three groups was performed using the calcaneal ultrasonometry and evaluated by image analysis: microtomography, X-ray diffraction, optical microscopy e scanning electron microscopy. The results showed, for the diseased bone, degradation, reduction in the histomorfometric parameters and lower X-ray intensity. It is concluded that this characteristics indicates a validation in the assessment of fracture risk

10 June 2021 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
Alessandro Marcio Hakme da SilvaAlessandro Marcio Hakme da Silva
Alessandro Marcio Hakme da Silva
LRLuis G.C. Romagnolo
Luis G.C. Romagnolo
FFFelipe Campos Ferreira
Felipe Campos Ferreira
EBEmilio de Almeida Belmonte
Emilio de Almeida Belmonte
LSLucas Alves de Souza
Lucas Alves de Souza
JCJonas de Carvalho
Jonas de Carvalho
Due to COVID-19 outbreak, many sectors around the globe have been facing the most diverse crisis. Regarding the health system, hospitals all over the world have been going through, among so many challenges, shortage of resources that could, if available, help them on the fight against COVID-19, and even save the lives of their patients. This review paper aims to offer for both healthcare providers and patients, better conditions when fighting the disease, regarding the actual primary care shortage, and addressing a splitting valve concept coupled to the mechanical ventilators in the most severe cases. The automated valve development with a monitoring and analysis system for pulmonary mechanics will stablish the database parameters of patients with COVid-19 and SARS, in order to assist the medical team in the treatment of diseases and the average evolution of the clinical condition of patients at an early stage, contributing to a reduction in the time of hospitalization and treatment and mortality. These information is saved on a database shared with other hospitals, allowing a search for matching patients; with similar or same pulmonary compliance, gender, height, weight, respiratory frequency and, in most severe cases when the patient needs mechanical ventilation, the availability of the nearest treatment is verified viewing immediate care. Regarding the mechanical ventilator device usage, the automated valve views engaged to a human-machine interface from the systems hardware allows the treatment of multiple patients, under the same ventilator, in an individualized way. To achieve that, pressure transducers and controllers of flow and temperature will continuously monitor the adequate flow of air and pressure to each patient that are under the same ventilator. Moreover, when monitoring each patient among the health units and hospitals integrated to the system, the medical team is helped defining the best strategy to the treatment stage and, by these means, the use of mechanical ventilator by the CoVID-19 patient is amplified, allowing to attend more than one patient who will need mechanical ventilation with SARS an accuracy treatment and monitoring method.

28 November 2024 in Periodontal and Implant Research
Verified
Journal Article
Closed access
PDF file
PFP. G. Fernandes
P. G. Fernandes
Alessandro Marcio Hakme da SilvaAlessandro Marcio Hakme da Silva
Alessandro Marcio Hakme da Silva
TSThiago Domingues Stocco
Thiago Domingues Stocco
DMDaniel Magalhaes
Daniel Magalhaes
JVJ. M. T. M. M. Vanderlei
J. M. T. M. M. Vanderlei
Mario Taba JrMario Taba Jr
Mario Taba Jr