Alex G. Kuchumov

Dr. Alex G. Kuchumov

Perm National Research Polytechnic University, Komsomol'skiy, Russia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2023 in Fluids
Verified
Journal Article
Open access
PDF file
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
AMAnastasia Makashova
Anastasia Makashova
SVSergey Vladimirov
Sergey Vladimirov
VBVsevolod Pavlovich Borodin
Vsevolod Pavlovich Borodin
ADAnna Dokuchaeva
Anna Dokuchaeva
The complicated interaction between a fluid flow and a deformable structure is referred to as fluid–structure interaction (FSI). FSI plays a crucial role in the functioning of the aortic valve. Blood exerts stresses on the leaflets as it passes through the opening or shutting valve, causing them to distort and vibrate. The pressure, velocity, and turbulence of the fluid flow have an impact on these deformations and vibrations. Designing artificial valves, diagnosing and predicting valve failure, and improving surgical and interventional treatments all require the understanding and modeling of FSI in aortic valve dynamics. The most popular techniques for simulating and analyzing FSI in aortic valves are computational fluid dynamics (CFD) and finite element analysis (FEA). By studying the relationship between fluid flow and valve deformations, researchers and doctors can gain knowledge about the functioning of valves and possible pathological diseases. Overall, FSI is a complicated phenomenon that has a great impact on how well the aortic valve works. Aortic valve diseases and disorders can be better identified, treated, and managed by comprehending and mimicking this relationship. This article provides a literature review that compiles valve reconstruction methods from 1952 to the present, as well as FSI modeling techniques that can help advance valve reconstruction. The Scopus, PubMed, and ScienceDirect databases were used in the literature search and were structured into several categories. By utilizing FSI modeling, surgeons, researchers, and engineers can predict the behavior of the aortic valve before, during, and after surgery. This predictive capability can contribute to improved surgical planning, as it provides valuable insights into hemodynamic parameters such as blood flow patterns, pressure distributions, and stress analysis. Additionally, FSI modeling can aid in the evaluation of different treatment options and surgical techniques, allowing for the assessment of potential complications and the optimization of surgical outcomes. It can also provide valuable information on the long-term durability and functionality of prosthetic valves. In summary, fluid–structure interaction modeling is an effective tool for predicting the outcomes of aortic valve surgery. It can provide valuable insights into hemodynamic parameters and aid in surgical planning, treatment evaluation, and the optimization of surgical outcomes.

13 January 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
NPNikita Pil
Nikita Pil
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
BKBakytbek Kadyraliev
Bakytbek Kadyraliev
VAVagram Arutunyan
Vagram Arutunyan
Long-term fiber tissue remodeling and the progressive thickening of the aortic valve leaflets called calcific aortic stenosis lead to cardiac blood outflow obstruction. This disease is the most prevalent heart valve pathology in developed countries. Surgeons can perform aortic valve replacement through traditional open-heart surgery involving a cut (incision) in the chest or use minimally invasive methods such as transcatheter aortic valve implantation (TAVI). These types of surgery have numerous advantages and limitations. Recently, the Ozaki operation for aortic valve replacement using tissue from the autologous pericardium has been proposed. Despite being a promising technique for aortic valve pathology treatment, there is a lack of long-term results and optimal selection of leaflet sizing. Numerical fluid simulations can help surgeons predict operation outcomes for each patient. Nevertheless, the description of the material model for leaflet mechanics leaves an open question. Furthermore, selecting the most suitable model to describe the different conditions of the aortic valve is difficult. We performed a numerical analysis of aortic valve leaflet material models to describe the hemodynamics in normal, pathological, and Ozaki cases. We also reveal wall shear stress, von Mises stress, and displacement distributions. Based on the parameters mentioned above, we found that the Ozaki case model behaved similarly to the mathematical model describing the normal case. Numerical simulations also provide information on the mechanisms of aortic valve work in different states of the heart cycle.

1 February 2014 in Korea-Australia Rheology Journal
Verified
Journal Article
Closed access
PDF file
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
VGValeriy Gilev
Valeriy Gilev
VPVitaliy Popov
Vitaliy Popov
VSVladimir Samartsev
Vladimir Samartsev
VGVasiliy Gavrilov
Vasiliy Gavrilov

26 June 2021 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
VVVasily Vedeneev
Vasily Vedeneev
VSVladimir Samartsev
Vladimir Samartsev
AKAleksandr Khairulin
Aleksandr Khairulin
OIOleg Ivanov
Oleg Ivanov
Gallbladder disease is one of the most spread pathologies in the world. Despite the number of operations dealing with biliary surgery increases, the number of postoperative complications is also high. The aim of this study is to show the influence of the biliary system pathology on bile flow character and to numerically assess the effect of surgical operation (cholecystectomy) on the fluid dynamics in the extrahepatic biliary tree, and also to reveal the difference between 1-way and 2-way FSI algorithms on the results. Moreover, the bile viscosity and biliary tree geometry influence on the choledynamics were evaluated. Bile velocity, pressure, wall shear stress (WSS), displacements and von Mises stress distributions in the extrahepatic biliary tree are presented, and comparison is made between a healthy and a lithogenic bile. The patient-specific biliary tree model is created using magnetic resonance imaging (MRI) and imported in a commercial finite element analysis software. It is found that in the case of lithogenic bile, velocities have lower magnitude while pressures are higher. Furthermore, stress analysis of the bile ducts shows that the WSS distribution is found mostly prevailing in the common hepatic duct and common bile duct areas. It is shown that when it is necessary to evaluate the bile flow dynamics in urgent medical situations, 1-way analysis is acceptable. Nevertheless, 2-way FSI provides more accurate data, if necessary to evaluate the stress–strain state of bile ducts. The proposed model can be applied to medical practice to reduce the number of post-operative complications.

7 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
AKAleksandr Khairulin
Aleksandr Khairulin
MSMarina Shmurak
Marina Shmurak
Artem PorodikovArtem Porodikov
Artem Porodikov
AMAndrey Merzlyakov
Andrey Merzlyakov
Cardiovascular surgery requires the use of state-of-the-art artificial materials. For example, microporous polytetrafluoroethylene grafts manufactured by Gore-Tex® are used for the treatment of cyanotic heart defects (i.e., modified Blalock–Taussig shunt). Significant mortality during this palliative operation has led surgeons to adopt mathematical models to eliminate complications by performing fluid–solid interaction (FSI) simulations. To proceed with FSI modeling, it is necessary to know either the mechanical properties of the aorta and graft or the rheological properties of blood. The properties of the aorta and blood can be found in the literature, but there are no data about the mechanical properties of Gore-Tex® grafts. Experimental studies were carried out on the mechanical properties vascular grafts adopted for modified pediatric Blalock–Taussig shunts. Parameters of two models (the five-parameter Mooney–Rivlin model and the three-parameter Yeoh model) were determined by uniaxial experimental curve fitting. The obtained data were used for patient-specific FSI modeling of local blood flow in the “aorta-modified Blalock–Taussig shunt–pulmonary artery” system in three different shunt locations: central, right, and left. The anisotropic model of the aortic material showed higher stress values at the peak moment of systole, which may be a key factor determining the strength characteristics of the aorta and pulmonary artery. Additionally, this mechanical parameter is important when installing a central shunt, since it is in the area of the central anastomosis that an increase in stress on the aortic wall is observed. According to computations, the anisotropic model shows smaller values for the displacements of both the aorta and the shunt, which in turn may affect the success of preoperative predictions. Thus, it can be concluded that the anisotropic properties of the aorta play an important role in preoperative modeling.

12 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
NKNikita Kharin
Nikita Kharin
PBPavel Bolshakov
Pavel Bolshakov
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
Prosthetic reconstructions provide anatomical reconstruction to replace bones and joints. However, these operations have a high number of short- and long-term complications. One of the main problems in surgery is that the implant remains in the body after the operation. The solution to this problem is to use biomaterial for the implant, but biomaterial does not have the required strength characteristics. The implant must also have a mesh-like structure so that the bone can grow into the implant. The additive manufacturing process is ideal for the production of such a structure. The study deals with the correlation between different prosthetic structures, namely, the relationship between geometry, mechanical properties and biological additivity. The main challenge is to design an endoprosthesis that will mimic the geometric structure of bone and also meet the conditions of strength, hardness and stiffness. In order to match the above factors, it is necessary to develop appropriate algorithms. The main objective of this study is to augment the algorithm to ensure minimum structural weight without changing the strength characteristics of the lattice endoprosthesis of long bones. The iterative augmentation process of the algorithm was implemented by removing low-loaded ribs. A low-loaded rib is a rib with a maximum stress that is less than the threshold stress. Values within the range (10, 13, 15, 16, 17, 18, 19 and 20 MPa) were taken as the threshold stress. The supplement to the algorithm was applied to the initial structure and the designed structure at threshold stresses σf = 10, 13, 15, 16, 17, 18, 19 and 20 MPa. A Pareto diagram for maximum stress and the number of ribs is plotted for all cases of the design: original, engineered and lightened structures. The most optimal was the designed “lightweight” structure under the condition σf = 17 MPa. The maximum stress was 147.48 MPa, and the number of ribs was 741. Specimens were manufactured using additive manufacturing and then tested for four-point bending.