Anna Dokuchaeva

Mrs. Anna Dokuchaeva

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2023 in Fluids
Verified
Journal Article
Open access
PDF file
Alex G. KuchumovAlex G. Kuchumov
Alex G. Kuchumov
AMAnastasia Makashova
Anastasia Makashova
SVSergey Vladimirov
Sergey Vladimirov
VBVsevolod Pavlovich Borodin
Vsevolod Pavlovich Borodin
ADAnna Dokuchaeva
Anna Dokuchaeva
The complicated interaction between a fluid flow and a deformable structure is referred to as fluid–structure interaction (FSI). FSI plays a crucial role in the functioning of the aortic valve. Blood exerts stresses on the leaflets as it passes through the opening or shutting valve, causing them to distort and vibrate. The pressure, velocity, and turbulence of the fluid flow have an impact on these deformations and vibrations. Designing artificial valves, diagnosing and predicting valve failure, and improving surgical and interventional treatments all require the understanding and modeling of FSI in aortic valve dynamics. The most popular techniques for simulating and analyzing FSI in aortic valves are computational fluid dynamics (CFD) and finite element analysis (FEA). By studying the relationship between fluid flow and valve deformations, researchers and doctors can gain knowledge about the functioning of valves and possible pathological diseases. Overall, FSI is a complicated phenomenon that has a great impact on how well the aortic valve works. Aortic valve diseases and disorders can be better identified, treated, and managed by comprehending and mimicking this relationship. This article provides a literature review that compiles valve reconstruction methods from 1952 to the present, as well as FSI modeling techniques that can help advance valve reconstruction. The Scopus, PubMed, and ScienceDirect databases were used in the literature search and were structured into several categories. By utilizing FSI modeling, surgeons, researchers, and engineers can predict the behavior of the aortic valve before, during, and after surgery. This predictive capability can contribute to improved surgical planning, as it provides valuable insights into hemodynamic parameters such as blood flow patterns, pressure distributions, and stress analysis. Additionally, FSI modeling can aid in the evaluation of different treatment options and surgical techniques, allowing for the assessment of potential complications and the optimization of surgical outcomes. It can also provide valuable information on the long-term durability and functionality of prosthetic valves. In summary, fluid–structure interaction modeling is an effective tool for predicting the outcomes of aortic valve surgery. It can provide valuable insights into hemodynamic parameters and aid in surgical planning, treatment evaluation, and the optimization of surgical outcomes.

17 January 2022 in Polymers
Verified
Journal Article
Open access
PDF file
ADAnna Dokuchaeva
Anna Dokuchaeva
TTTatyana P. Timchenko
Tatyana P. Timchenko
EKElena Karpova
Elena Karpova
SVSergei V. Vladimirov
Sergei V. Vladimirov
ISIlya A. Soynov
Ilya A. Soynov
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
Electrospinning is a perspective method widely suggested for use in bioengineering applications, but the variability in currently available data and equipment necessitates additional research to ascertain the desirable methodology. In this study, we aimed to describe the effects of electrospinning technique alterations on the structural and mechanical properties of (1,7)-polyoxepan-2-one (poly-ε-caprolactone, PCL) scaffolds, such as circumferential and longitudinal stress/strain curves, in comparison with corresponding properties of fresh rat aorta samples. Scaffolds manufactured under different electrospinning modes were analyzed and evaluated using scanning electronic microscopy as well as uniaxial longitudinal and circumferential tensile tests. Fiber diameter was shown to be the most crucial characteristic of the scaffold, correlating with its mechanical properties.

15 August 2022 in Polymers
Verified
Journal Article
Open access
PDF file
ADAnna Dokuchaeva
Anna Dokuchaeva
AMAleksandra B. Mochalova Mochalova
Aleksandra B. Mochalova Mochalova
TTTatyana P. Timchenko
Tatyana P. Timchenko
KPKseniya S. Podolskaya
Kseniya S. Podolskaya
OPOxana Pashkovskaya
Oxana Pashkovskaya
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
Electrospun tissue-engineered grafts made of biodegradable materials have become a perspective search field in terms of vascular replacement, and more research is required to describe their in vivo transformation. This study aimed to give a detailed observation of hemodynamic and structural properties of electrospun, monolayered poly-ε-caprolactone (PCL) grafts in an in vivo experiment using a rat aorta replacement model at 10, 30, 60 and 90 implantation days. It was shown using ultrasound diagnostic and X-ray tomography that PCL grafts maintain patency throughout the entire follow-up period, without stenosis or thrombosis. Vascular compliance, assessed by the resistance index (RI), remains at the stable level from the 10th to the 90th day. A histological study using hematoxylin-eosin (H&E), von Kossa and Russell–Movat pentachrome staining demonstrated the dynamics of tissue response to the implant. By the 10th day, an endothelial monolayer was forming on the graft luminal surface, followed by the gradual growth and compaction of the neointima up to the 90th day. The intense inflammatory cellular reaction observed on the 10th day in the thickness of the scaffold was changed by the fibroblast and myofibroblast penetration by the 30th day. The cellularity maximum was reached on the 60th day, but by the 90th day the cellularity significantly (p = 0.02) decreased. From the 60th day, in some samples, the calcium phosphate depositions were revealed at the scaffold-neointima interface. Scanning electron microscopy showed that the scaffolds retained their fibrillar structure up to the 90th day. Thus, we have shown that the advantages of PCL scaffolds are excellent endothelialization and good surgical outcome. The disadvantages include their slow biodegradation, ineffective cellularization, and risks for mineralization and intimal hyperplasia.

2 August 2020 in Marine Drugs
Verified
Journal Article
Open access
PDF file
David SergeevichevDavid Sergeevichev
David Sergeevichev
Vladislav V. FomenkoVladislav V. Fomenko
Vladislav V. Fomenko
ASArtem Strelnikov
Artem Strelnikov
ADAnna Dokuchaeva
Anna Dokuchaeva
MVMaria Vasilieva
Maria Vasilieva
АCАлександр Михайлович Chernyavskiy
Александр Михайлович Chernyavskiy
Several experimental studies have recently demonstrated that temporary autonomic block using botulinum toxin (BoNT/A1) might be a novel option for the treatment of atrial fibrillation. However, the assessment of antiarrhythmic properties of BoNT has so far been limited, relying exclusively on vagal stimulation and rapid atrial pacing models. The present study examined the antiarrhythmic effect of specially formulated BoNT/A1-chitosan nanoparticles (BTN) in calcium chloride-, barium chloride- and electrically induced arrhythmia rat models. BTN enhanced the effect of BoNT/A1. Subepicardial injection of BTN resulted in a significant antiarrhythmic effect in investigated rat models. BTN formulation antagonizes arrhythmia induced by the activation of Ca, K and Na channels.

Verified
Journal Article
Open access
PDF file
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
EKElena Karpova
Elena Karpova
ADAnna Dokuchaeva
Anna Dokuchaeva
ATAnatoly Titov
Anatoly Titov
TTTatiana P. Timchenko
Tatiana P. Timchenko
MVMaria B. Vasilieva
Maria B. Vasilieva
The causes of heart valve bioprosthetic calcification are still not clear. In this paper, we compared the calcification in the porcine aorta (Ao) and the bovine jugular vein (Ve) walls, as well as the bovine pericardium (Pe). Biomaterials were crosslinked with glutaraldehyde (GA) and diepoxide (DE), after which they were implanted subcutaneously in young rats for 10, 20, and 30 days. Collagen, elastin, and fibrillin were visualized in non-implanted samples. Atomic absorption spectroscopy, histological methods, scanning electron microscopy, and Fourier-transform infrared spectroscopy were used to study the dynamics of calcification. By the 30th day, calcium accumulated most intensively in the collagen fibers of the GA-Pe. In elastin-rich materials, calcium deposits were associated with elastin fibers and localized differences in the walls of Ao and Ve. The DE-Pe did not calcify at all for 30 days. Alkaline phosphatase does not affect calcification since it was not found in the implant tissue. Fibrillin surrounds elastin fibers in the Ao and Ve, but its involvement in calcification is questionable. In the subcutaneous space of young rats, which are used to model the implants’ calcification, the content of phosphorus was five times higher than in aging animals. We hypothesize that the centers of calcium phosphate nucleation are the positively charged nitrogen of the pyridinium rings, which is the main one in fresh elastin and appears in collagen as a result of GA preservation. Nucleation can be significantly accelerated at high concentrations of phosphorus in biological fluids. The hypothesis needs further experimental confirmation.

Verified
Journal Article
Open access
PDF file
ADAnna Dokuchaeva
Anna Dokuchaeva
SVSergey V. Vladimirov
Sergey V. Vladimirov
VBVsevolod Borodin
Vsevolod Borodin
EKElena Karpova
Elena Karpova
AVAndrey A. Vaver
Andrey A. Vaver
IZIrina Y. Zhuravleva
Irina Y. Zhuravleva
Carbon nanotubes (CNTs) are used in applications ranging from electrical engineering to medical device manufacturing. It is well known that the addition of nanotubes can influence the mechanical properties of various industrial materials, including plastics. Electrospinning is a popular method for fabricating nanomaterials, widely suggested for polymer scaffold manufacturing. In this study, we aimed to describe the influence of single-walled carbon nanotube (SWCNT) suspensions on polymeric poured films and electrospun scaffolds and to investigate their structural and mechanical properties obtained from various compositions. To obtain films and electrospun scaffolds of 8 mm diameter, we used poly-ε-caprolactone (PCL) and poly(cyclohexene carbonate) (PCHC) solutions containing several mass fractions of SWCNT. The samples were characterized using tensile tests, atomic force and scanning electronic microscopy (AFM and SEM). All the studied SWCNT concentrations were shown to decrease the extensibility and strength of electrospun scaffolds, so SWCNT use was considered unsuitable for this technique. The 0.01% mass fraction of SWCNT in PCL films increased the polymer strength, while fractions of 0.03% and more significantly decreased the polymer strength and extensibility compared to the undoped polymer. The PHCH polymeric films showed a similar behavior with an extremum at 0.02% concentration for strength at break.