mohammad alqubaiisey

Dr. mohammad alqubaiisey

King Saud University, Riyadh, Ar Riyāḑ, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2022 in Antibiotics
Verified
Journal Article
Open access
PDF file
MAmohammad alqubaiisey
mohammad alqubaiisey
RKRITA Meguerditch KHOUNGANIAN
RITA Meguerditch KHOUNGANIAN
AAAbdulhakim Al-Badah
Abdulhakim Al-Badah
This investigation was conducted to evaluate the efficacy of coated titanium plates against gram-positive Staphylococcus aureus (SA) and gram-negative Pseudomonas aeruginosa (PA) using various methods. The Colony-forming unit “CFU” was higher in chitosan (CH) in relation to PA than in poly lactic-co-glycolic acid (PLGA) in relation to SA, followed by meropenem-chitosan “MC” coated plates in relation to PA and SA. A significant difference in the zone of inhibition (ZOI) of SA was determined in MP, MC, and meropenem (MEM). PA was significantly inhibited by MP, MEM, then MC, and the largest ZOI among SA and PA groups were MP coating. Using an MTT assay, MP had the lowest bacterial viability in the SA group, followed by MC and MEM, with no statistically significant difference between the PLGA or CH alone nor the polymers augmented with MEM. Using confocal microscopy, MP-coated plates were seen to have the highest bacterial inhibition, followed by MC, MEM, PLGA, and CH. In the PA group, MP had the highest bacterial inhibition, followed by MEM, MC, CH, and PLGA. The uncoated group presented the lowest inhibition in relation to both SA and PA. Conclusively, coating titanium plates with PLGA or CH with MEM appeared to enhance the antibacterial efficacy as opposed to MEM without polymers through bacterial adhesion inhibition, hindering biofilm formation and preventing bacterial proliferation.

5 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAmohammad alqubaiisey
mohammad alqubaiisey
RKRITA Meguerditch KHOUNGANIAN
RITA Meguerditch KHOUNGANIAN
SSSaeed Ali Syed
Saeed Ali Syed
SSSameh Seif
Sameh Seif
In some cases, titanium plates could be a reservoir for harboring bacteria resulting in challenging cases of infection. Current estimates indicate that 10–12% of plates require removal due to infection, exposure, pain, and discomfort. The present investigation was conducted to evaluate the potential sustained meropenem-coated plates amalgamated with “PLGA” polylactic co-glycolic acid and chitosan polymers with the concurrent sterilization effect of gamma irradiation. After coating the plates with either M “meropenem”, MP “meropenem-PLGA, or MC “meropenem-chitosan”, they were divided into two groups of sterile and non-sterile coated plates. The drug release was studied over three-time intervals of 1, 3, and 7 days using ultrahigh-performance liquid chromatography. Overall, the three materials had similar drug release on day one, both in sterile and non-sterile groups, while on days 3 and 7, a noticeable increase in the drug release was perceived in favor of MP. At the same time, no statistically significant difference was observed between sterile and non-sterile groups. A statistically significant increase in drug release was observed between and within the materials over time, with no overall difference between sterile and non-sterile groups.

26 November 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MAmohammad alqubaiisey
mohammad alqubaiisey
RKRITA Meguerditch KHOUNGANIAN
RITA Meguerditch KHOUNGANIAN
AAAbdulhakim Al-Badah
Abdulhakim Al-Badah
RARAISUDDIN ALI
RAISUDDIN ALI
The present investigation was undertaken to evaluate the topographical and ultrastructural architecture of titanium plates coated with polylactic co-glycolic acid (PLGA), chitosan (CH), and/or meropenem (MEM) with or without Staphylococcus aureus (SA) or Pseudomonas aeruginosa (PA) bacteria. Single-hole segments of 0.4 mm thick, low-profile titanium plates were spray coated using an airbrush with polymeric carriers (PLGA or CH) loaded with MEM, in addition to the negative control group (uncoated titanium plates). The coated plates and the negative control group were subjected to bacterial biofilms through a cultivation process while being slowly stirred at 20 rpm for 24 h. The samples were fixed and processed for scanning electron microscopic study at 5, 10, and 20 k magnification. The data were statistically analyzed to compare within and between the different materials. Coating titanium plates with PLGA or CH with MEM appeared to enhance bacterial inhibition over uncoated plates, hindering biofilm formation and preventing bacterial proliferation. In the staphylococcus aureus group, the highest bacterial count was observed in the uncoated plates, whereas the lowest count was detected in meropenem-PLGA, followed by PLGA, chitosan, meropenem, and meropenem-chitosan, respectively. On the other hand, the Pseudomonas aeruginosa group with the uncoated plates had the highest bacterial count, whereas the lowest bacterial count was found related to CH, followed by PLGA, MP, MC, and MEM, respectively.