Álvaro Sainz Calvo

Mr. Álvaro Sainz Calvo

Department of Analytical Chemistry, Universidad de Cádiz, Cádiz, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2025 in Microchimica Acta
Verified
Journal Article
Open access
PDF file
Álvaro Sainz CalvoÁlvaro Sainz Calvo
Álvaro Sainz Calvo
Alfonso Sierra-PadillaAlfonso Sierra-Padilla
Alfonso Sierra-Padilla
DBDolores Bellido-Milla
Dolores Bellido-Milla
LBLorena Blanco-Díaz
Lorena Blanco-Díaz
JAJuan Jesus Fernandez Alba
Juan Jesus Fernandez Alba
Laura M Cubillana-AguileraLaura M Cubillana-Aguilera
Laura M Cubillana-Aguilera
Enzyme saturation in biosensing has been established as a main hindrance in lactate monitoring due to the high concentration of this species in biological samples. In this paper, a Sonogel–carbon transducer has been used for the fabrication of an amperometric biosensor for lactate (LA) determination. The sensor was constructed by immobilizing lactate oxidase as the bioreceptor and coating the electrode surface with multipolymer layers to minimize enzyme saturation and improve operational stability. This biosensor shows adequate sensitivity (1.74 µA mM − 1 cm -2 ) in a linear working range from 0.2 mM to 20 mM, suitable for physiological lactate concentrations in biofluids. The response of the biosensor was studied in physiological medium using several potential interferents (glucose, uric acid, dopamine, ascorbic acid, KCl, NaCl, CaCl 2 and BSA), demonstrating negligible interference from these common electroactive species. A microfluidic cell was designed and fabricated using polyethylene terephthalate glycol (PETG) through a rapid and low-cost 3D printing process. Finally, the prepared microfluidic cell was applied to lactate monitoring in flow regime using the biosensor with both synthetic and real untreated human serum samples, showing excellent correlation with two standard reference techniques and confirming its reliability. These results highlight the potential of the proposed microfluidic amperometric biosensor as a robust, real-time tool for biomedical lactate monitoring. Graphical Abstract

11 February 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
Álvaro Sainz CalvoÁlvaro Sainz Calvo
Álvaro Sainz Calvo
Alfonso Sierra-PadillaAlfonso Sierra-Padilla
Alfonso Sierra-Padilla
DBDolores Bellido-Milla
Dolores Bellido-Milla
Laura M Cubillana-AguileraLaura M Cubillana-Aguilera
Laura M Cubillana-Aguilera
Juan García-GuzmánJuan García-Guzmán
Juan García-Guzmán
Jose Maria Palacios-SantanderJose Maria Palacios-Santander
Jose Maria Palacios-Santander
In the present work, a novel and economical pH sensor has been improved through the application of the conducting polymers poly(3,4-ethylendioxythiphene) and poly(sodium 4-styrene sulphonate). Sinusoidal voltages were applied to electrodeposit the different polymers studied for different periods (10, 15, and 20 min) on the electrode surface. The presence of polyaniline and its reversible redox structure have been corroborated by cyclic voltammetry. The working range has been increased from 3–8 to 2–12, obtaining adequate sensibility and linearity. This new sensor presented satisfactory repeatability, reproducibility (RSD < 5%), AND reversibility (pH range 2–12), and excellent selectivity towards H+ in the presence of diverse interferents in agrifood samples. Finally, the sensor was used to measure the pH in several real samples, whose pH values ranged from 2.23 to 11.5, obtaining excellent results. In addition, the values found were very similar to those reported by the gold technique (pH meter), with an error of less than 10% for most of the samples analyzed. In addition, a preliminary survey about measurements in a continuous flow, using a 3D homemade microfluidic cell, was performed with promising results.

26 December 2023 in Talanta
Verified
Journal Article
Open access
Juan García-GuzmánJuan García-Guzmán
Juan García-Guzmán
Álvaro Sainz CalvoÁlvaro Sainz Calvo
Álvaro Sainz Calvo
ASAlfonso Sierra-Padilla
Alfonso Sierra-Padilla
DBDolores Bellido-Milla
Dolores Bellido-Milla
Laura M Cubillana-AguileraLaura M Cubillana-Aguilera
Laura M Cubillana-Aguilera
Jose Maria Palacios-SantanderJose Maria Palacios-Santander
Jose Maria Palacios-Santander
The present work introduces two novel approaches to fabricate simple and cost-effective pH and temperature probes. Sinusoidal voltage methodologies were employed to electrodeposit polyaniline (PANI) at different growth times (10-20 min) on the surface of an affordable Sonogel-Carbon electrode to conform a robust pH sensor. The presence of PANI and its phases were corroborated by electrochemical means. The sensibility, reversibility and selectivity of the produced sensor were very adequate to apply it in physiological samples. In this regard, the proposed sensor was evaluated in artificial blood serum as well as untreated plasma samples obtaining outstanding results in comparison with a gold reference technique (error <2 %). In addition, a new composite sonogel material, intrinsically modified with multiwalled carbon nanotubes, was attached on top of an electrode couple to one-step fabricate a new temperature probe, relating resistance of the probe with the surroundings temperature. In this case, an optical microscopy characterization was performed to study the sturdiness of the layer. Remarkably, suitable results in terms of sensitivity and selectivity were obtained. The probes were assessed in artificial and untreated plasma samples as well, with the corresponding validation step (error <1 %) by using a commercial temperature probe.

25 February 2026 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
Álvaro Sainz CalvoÁlvaro Sainz Calvo
Álvaro Sainz Calvo
ÁCÁlvaro Cordero-Hernández
Álvaro Cordero-Hernández
MJMarina Jiménez-Rodríguez
Marina Jiménez-Rodríguez
VGVirginia García-Rodríguez
Virginia García-Rodríguez
Juan García-GuzmánJuan García-Guzmán
Juan García-Guzmán
Laura M Cubillana-AguileraLaura M Cubillana-Aguilera
Laura M Cubillana-Aguilera
In the present work, two potentiometric sensors for the simultaneous determination of sodium and potassium ions were successfully developed. A novel functionalized multi-walled carbon nanotube sonogel-based mixture served as ion-to-electron transducer, while sodium and potassium cocktail membranes were employed as ion-selective membranes. Both sensors exhibit a well-defined operational range suitable for the precise quantification of these cations in the biomedical range, the sensors showed linear ranges of 38–4400 and 0.31–314 mM for sodium and potassium, respectively. The LOD and LOQ were 0.28/0.31 mM and 0.38/0.64 mM, respectively while the sensitivities were 58.3 ± 0.5 and 54 ± 0.2 mV per decade. The sensors demonstrate outstanding repeatability, reproducibility, and reversibility, with relative standard deviations (% RSD) below 5%, as well as exceptional selectivity for Na+ and K+ ions in the presence of various interferent substances commonly found in biological matrices. Furthermore, the sensors were applied for the simultaneous determination of sodium and potassium in untreated human plasma and serum samples under continuous flow conditions using a microfluidic cell, whose fabrication is really simple using 3D printing and cost of fabrication is less than 1 euro, and requiring only a minimal sample volume (∼300 μL). The analytical results obtained showed an error margin of less than 5% across all tested samples, highlighting the sensor's reliability and potential applicability in clinical diagnostics. Notably, an excellent correlation was observed with the reference technique routinely employed in hospitals, the blood gas analyser, further supporting clinical relevance of the sensors. These findings underscore the practical utility of the developed sensors for rapid and accurate ion monitoring in complex biological fluids.

27 October 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Juan García-GuzmánJuan García-Guzmán
Juan García-Guzmán
Álvaro Sainz CalvoÁlvaro Sainz Calvo
Álvaro Sainz Calvo
APAna Pérez-Fernández
Ana Pérez-Fernández
Alfonso Sierra-PadillaAlfonso Sierra-Padilla
Alfonso Sierra-Padilla
DBDolores Bellido-Milla
Dolores Bellido-Milla
Jose Maria Palacios-SantanderJose Maria Palacios-Santander
Jose Maria Palacios-Santander
In this work two new different sensors are developed: a pH sensor and a temperature probe. The former is based on an electrodeposited polyaniline (PANI) layer employing sinusoidal voltages and optimizing the deposition time (10–20 min). On the other hand, the temperature probe was designed by taking advantage of the carbon nanotubes’ temperature properties. Both sensors were built on sonogel-carbon electrodes, seeking cost effective devices. In both scenarios, the results were satisfactory; the repeatability and reproducibility had values below 5%. Additionally, an excellent pH sensor selectivity was evaluated with the challenging interstitial matrix, prospecting an adequate future employment in real clinical samples.