ANAS MOHD NOOR

Dr. ANAS MOHD NOOR

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
MSMuhammad Faiz Md Shakhih
Muhammad Faiz Md Shakhih
ARAnis Suzziani Rosslan
Anis Suzziani Rosslan
ANANAS MOHD NOOR
ANAS MOHD NOOR
SRSantheraleka Ramanathan
Santheraleka Ramanathan
ALAzwan Mat Lazim
Azwan Mat Lazim
AWAsnida Abdul Wahab
Asnida Abdul Wahab
Lactate is one of the potential biomarkers for assessing the human condition in clinical medicine or sports application. Lactate measurement could help in alerting various emergency conditions, such as bleeding, hypoxia, respiratory failure, and sepsis. Lactate monitoring could also benefit athletes in monitoring their muscle activity to prevent injury due to excessive muscle use or fatigue. In light of this, biosensor technology has been widely explored, especially on the use of electrochemical sensors to analyze the content of biological samples through direct biological activities conversion to electronic signals. This has become imperative for the detection of lactate which offers easy, quick, and reliable measurement. Despite enzymatic sensors being the focus of many studies, the non-enzymatic sensor has started to gain attention in recent years to overcome the stability issue of enzymes. This review presents an overview of the concepts, applications, and recent advancements of different electrochemical lactate sensors. A comparison of recent studies for both enzymatic and non-enzymatic lactate sensors based on electrode modification, enzymes, enzymes immobilizer, and several performance factors, including sensitivity, linearity, detection limit, and storage stability, all of which have been performed. Towards the end, this review also highlights some recommendations for future development of lactate sensors.

27 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
MMMazlee Mazalan
Mazlee Mazalan
ANANAS MOHD NOOR
ANAS MOHD NOOR
YWYufridin Wahab
Yufridin Wahab
SYShuhaida Yahud
Shuhaida Yahud
Wan Safwani Wan Kamarul ZamanWan Safwani Wan Kamarul Zaman
Wan Safwani Wan Kamarul Zaman
Acoustics have a wide range of uses, from noise-cancelling to ultrasonic imaging. There has been a surge in interest in developing acoustic-based approaches for biological and biomedical applications in the last decade. This review focused on the application of surface acoustic waves (SAW) based on interdigital transducers (IDT) for live-cell investigations, such as cell manipulation, cell separation, cell seeding, cell migration, cell characteristics, and cell behaviours. The approach is also known as acoustofluidic, because the SAW device is coupled with a microfluidic system that contains live cells. This article provides an overview of several forms of IDT of SAW devices on recently used cells. Conclusively, a brief viewpoint and overview of the future application of SAW techniques in live-cell investigations were presented.

10 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NINur Fatin Adini Ibrahim
Nur Fatin Adini Ibrahim
NSNorhayati Sabani
Norhayati Sabani
SJShazlina Johari
Shazlina Johari
AAAbd Manaf Asrulnizam
Abd Manaf Asrulnizam
AWAsnida Abdul Wahab
Asnida Abdul Wahab
ANANAS MOHD NOOR
ANAS MOHD NOOR
Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte’s response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.

20 April 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TMTaisuke Masuda
Taisuke Masuda
WSWoneui Song
Woneui Song
HNHayao Nakanishi
Hayao Nakanishi
WLWu Lei
Wu Lei
ANANAS MOHD NOOR
ANAS MOHD NOOR
FAFumihito Arai
Fumihito Arai
The ability to accurately detect and analyze rare cells in a cell population is critical not only for the study of disease progression but also for next flow cytometry systems in clinical application. Here, we report the development of a prototype device, the ‘Rare cell sorter’, for isolating and recovering single rare cells from whole blood samples. On this device, we utilized an open-channel microfluidic chip for rare cell isolation. And the advantage of open-channel allows us to recover the isolated rare cell directly from the chip. We set the circulating tumor cell (CTC) as a target cell. For the clinical experiment, CTCs were isolated from blood samples collected from patients with metastatic breast cancer and healthy volunteers. There was a significant difference in the number of CTCs between the patients with metastatic breast cancer and healthy volunteers. To evaluate the damage to cells during isolation and recovery, we performed an RNA integrity assay using RNA extracted from CTCs recovered from the chip and found that our process for single CTC isolation and recovery is mild enough for gene analysis of CTCs.

1 December 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ANANAS MOHD NOOR
ANAS MOHD NOOR
TMTaisuke Masuda
Taisuke Masuda
WLWu Lei
Wu Lei
KHKoji Horio
Koji Horio
YMYasuhiko Miyata
Yasuhiko Miyata
FAFumihito Arai
Fumihito Arai

15 June 2023 in HardwareX
Verified
Journal Article
Open access
NINur Fatin Adini Ibrahim
Nur Fatin Adini Ibrahim
ANANAS MOHD NOOR
ANAS MOHD NOOR
NSNorhayati Sabani
Norhayati Sabani
ZZZulkarnay Zakaria
Zulkarnay Zakaria
AWAsnida Abdul Wahab
Asnida Abdul Wahab
SJShazlina Johari
Shazlina Johari
Wearable technology, such as electronic components integrated into clothing or worn as accessories, is becoming increasingly prevalent in fields like healthcare and biomedical monitoring. These devices allow for continuous monitoring of important biomarkers for medical diagnosis, monitoring of physiological health, and evaluation. However, an open-source wearable potentiostat is a relatively new technology that still faces several design limitations such as short battery lifetime, bulky size, heavy weight, and the requirement for a wire for data transmission, which affects comfortability during long periods of measurement. In this work, an open-source wearable potentiostat device named We-VoltamoStat is developed to allow interested parties to use and modify the device for creating new products, research, and teaching purposes. The proposed device includes improved and added features, such as wireless real-time signal monitoring and data collection. It also has an ultra-low power consumption battery estimated to deliver 15 mA during operating mode for 33 h and 20 min and 5 mA during standby mode for 100 h without recharging. Its convenience for wearable applications, tough design, and compact size of 67x54x38 mm make it suitable for wearable applications. Cost-effectiveness is another advantage, with a price less than 120 USD. Validation performance tests indicate that the device has good accuracy, with an R2 value of 0.99 for linear regression of test accuracy on milli-, micro-, and nano-Ampere detection. In the future, it is recommended to improve the design and add more features to the device, including new applications for wearable potentiostats.