André Souza Araujo

Dr. André Souza Araujo

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

8 April 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
Isis PradoIsis Prado
Isis Prado
JCJoao P. R. S. Carvalho
Joao P. R. S. Carvalho
André Souza AraujoAndré Souza Araujo
André Souza Araujo
PNPaloma Napoleão-Pêgo
Paloma Napoleão-Pêgo
Salvatore Giovanni De-SimoneSalvatore Giovanni De-Simone
Salvatore Giovanni De-Simone
Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, there is still a huge demand for new diagnostic methods that provide rapid, low-cost, easy-to-use confirmation. Thus, in this study, we developed an affordable electrochemical biosensor for rapidly detecting immunoglobulin G (IgG) serological antibodies in the sera of DENV-infected patients. An identified linear B-cell epitope (DENV/18) specific for DENV 1–4 serotypes recognized by IgG in patient sera was selected as a target molecule after a microarray of peptides using the SPOT-synthesis methodology. After chemical synthesis, the DENV/18-peptide was immobilized on the surface of the working electrode of a commercially available screen-printed gold electrode (SPGE). The capture of DENV-specific IgG allowed for the formation of an immunocomplex that was measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using a potassium ferrocyanide/ferricyanide ([Fe(CN)6]3−/4−) electrochemical probe. An evaluation of the biosensor’s performance showed a detection limit of 100 µg mL−1 for the synthetic peptides (DENV/18) and 1.21 ng mL−1 in CV and 0.43 ng mL−1 in DPV for human serum, with a sensitivity of 7.21 µA in CV and 8.79 µA in DPV. The differentiation of infected and uninfected individuals was possible even at a high dilution factor that reduced the required sample volumes to a few microliters. The final device proved suitable for diagnosing DENV by analyzing real serum samples, and the results showed good agreement with molecular biology diagnostics. The flexibility to conjugate other antigenic peptides to SPEs suggests that this technology could be rapidly adapted to diagnose other pathogens.

1 October 2019 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
KMK.R.M. Macedo
K.R.M. Macedo
GOG.A.C. Oliveira
G.A.C. Oliveira
KPK.A.B. Pereira
K.A.B. Pereira
LML.C. Mendes
L.C. Mendes
André Souza AraujoAndré Souza Araujo
André Souza Araujo
RCRicardo Jorgensen Cassella
Ricardo Jorgensen Cassella


29 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Isis PradoIsis Prado
Isis Prado
JCJoão P.R.S. Carvalho
João P.R.S. Carvalho
André Souza AraujoAndré Souza Araujo
André Souza Araujo
PNPaloma Napoleão-Pêgo
Paloma Napoleão-Pêgo
Salvatore Giovanni De-SimoneSalvatore Giovanni De-Simone
Salvatore Giovanni De-Simone
Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, there is still a huge demand for new diagnostic methods that provide rapid, low-cost, easy-to-use confirmation. Thus, in this work, we developed an affordable electrochemical biosensor for rapidly detecting immunoglobulin G (IgG) serological antibodies in the sera of DENV-infected patients. Materials and methods: An identified linear B-cell epitope (DENV/18) specific for DENV 1-4 serotypes recognized by IgG in patient sera was selected as a target molecule after a microarray of peptides using the Spot-synthesis methodology. After chemical synthesis, the DENV/18-peptide was immobilized on the surface of the working electrode of a commercially available screen-printed gold electrode (SPGE). The capture of DENV-specific IgG allowed the formation of an immunocomplex that was measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using a potassium ferri-iron cyanide K+ ([Fe(CN)6]3-/4-) electrochemical probe. Results: An evaluation of the performance of the biosensor showed a detection limit of 100 µg mL-1 for the synthetic peptides (DENV/18) and 0.002 µg mL−1 for human serum, with a sensitivity of 7.21 µA in CV and 8.79 µA in DPV. The differentiation of infected and uninfected individuals was possible even at a high dilution factor that reduced the required sample volumes to a few microliters. Conclusion: The final device proved suitable for diagnosing DENV by analyzing real serum samples, and the results showed good agreement with molecular biology diagnostics. The flexibility to conjugate other antigenic peptides to SPEs suggests that this technology could be rapidly adapted to diagnose other pathogens.