2 August 2019 in High Voltage
Verified
Journal Article
Open access
PDF file
Arthur Francisco AndradeArthur Francisco Andrade
Arthur Francisco Andrade
ECEdson Guedes Da Costa
Edson Guedes Da Costa
JFJosué M.B. Fernandes
Josué M.B. Fernandes
HAHelem M.M. Alves
Helem M.M. Alves
CFCícero R.C. Amorim Filho
Cícero R.C. Amorim Filho
In this article, an analysis of heat transfer in a porcelain‐housed ZnO surge arrester is presented. Due to the fact that ZnO‐based surge arresters are key components for protection and reliability of electrical systems, it is necessary to seek techniques to assure correct assessment. In porcelain‐housed arresters, the air gap leads to an increased thermal resistance between the ambient and the varistor column. Consequently, a thermal analysis must consider convection and radiation heat transfer mechanisms, besides heat conduction. This study proposes the use of computational simulations in combination with thermography as a tool for a temperature‐based estimation of the varistor state. For the analysis, temperature rise tests were performed in a 69‐kV ceramic‐housed arrester to measure material emissivity and produce data to fit the simulated response. Furthermore, the thermal response of the surge arresters subject to an impulsive energy input was evaluated. The simulations allow to relate varistors temperature and housing temperature with regard to a specified amount of dissipated power. The obtained results show that the used technique can be an effective method for arrester monitoring and may allow to define assessing criteria for a porcelain‐housed arrester based on housing temperature measurements.

9 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
Arthur Francisco AndradeArthur Francisco Andrade
Arthur Francisco Andrade
ECEdson Guedes Da Costa
Edson Guedes Da Costa
FAFilipe Andrade
Filipe Andrade
CSClarice Soares
Clarice Soares
GLGeorge Lira
George Lira
International standards prescribe overvoltage tests to evaluate the insulating material performance of high-voltage cables. However, it is difficult to manage the electric fields at the cable ends when laboratory measurements are carried out because surface and external discharges occur at the cable termination. Therefore, this paper presents a procedure for designing cable terminations to reduce the electric field at the cable ends to appropriate levels even in the case of overvoltage tests. For this purpose, computer simulations of electric field distribution using the finite element method (FEM) were performed. A 35 kV cable model was employed as a sample. An voltage with RMS (root mean square) value of 300 kV was used as an overestimate of breakdown voltage for the internal insulating material. The cable termination model obtained through the proposed methodology allows an electric field reduction in air, preventing the occurrence of external discharges, and thus permitting the breakdown voltage measurement of the cable’s inner insulation.

8 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Arthur Francisco AndradeArthur Francisco Andrade
Arthur Francisco Andrade
ECEdson Guedes Da Costa
Edson Guedes Da Costa
MGMarconni F. B. R. Goncalves
Marconni F. B. R. Goncalves
GLGeorge Lira
George Lira
RTRomulo O. Teixeira
Romulo O. Teixeira
Modeling grounding systems is necessary for the calculation of ground potential rise (GPR), power system simulations and insulation coordination studies. In this work, a methodology for estimating equivalent circuit parameters through the optimization of the time-domain impulse response was developed. It allows to obtain equivalent circuits with positive parameters that accurately represent grounding systems considering both effects related to frequency and soil ionization. Additionally, linear and nonlinear equivalent circuits for calculating the impulse response of typical grounding systems were proposed. The Nelder-Mead optimization method was applied to adjust the circuit parameters. For evaluating the methodology developed and the proposed models, data from impulse current tests was used. It was found that the use of nonlinear circuits increases the accuracy of the simulated response, resulting in errors of less than 4% in the estimation of GPR. The proposed methodology allows obtaining representative circuits of typical grounding systems used in the electrical system. The circuits can be used for systemic studies and calculation of GPR considering short-circuit or lightning currents.

1 May 2020 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
Arthur Francisco AndradeArthur Francisco Andrade
Arthur Francisco Andrade
ECEdson G. Costa
Edson G. Costa
ANAntonio B. Oliveira Neto
Antonio B. Oliveira Neto
GLGeorge R.S. Lira
George R.S. Lira
TFTarso Ferreira
Tarso Ferreira
Multiple‐level and up‐and‐down test methods are commonly employed in laboratories to obtain the breakdown voltage distribution of self‐restoring insulation, which is applied for equipment evaluation and for risk calculation in insulation coordination studies. This study investigates the reliability of the methods and proposes a methodology for evaluating their performance. The accuracy and precision of the estimated distribution parameters were analysed considering the variation of the test parameters. Algorithms that simulate the random nature of the tests were developed and applied in simulations. Then, a case study of risk calculation was carried out. The results indicated that both methods estimate the critical flashover voltage with acceptable accuracy and precision, even for the minimum parameters defined by standards. However, estimating the standard deviation is the critical step of the tests. The proposed methodology allows parameter definition for a given reliability requirement in the case of the constant voltage method. In the case of the up‐and‐down method, however, high dispersion was observed for all analysed cases, which indicates that this method presents low reliability for calculating flashover risk and, therefore, its use for insulation coordination studies is not recommended.

18 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Arthur Francisco AndradeArthur Francisco Andrade
Arthur Francisco Andrade
GGGiovanny Marcellus Marcellus Borges Borges Galdino
Giovanny Marcellus Marcellus Borges Borges Galdino
Ronimack Trajano de Trajano de SouzaRonimack Trajano de Trajano de Souza
Ronimack Trajano de Trajano de Souza
NFNewton S. S. M. Fonseca
Newton S. S. M. Fonseca
ANAntonio Francisco Leite Neto
Antonio Francisco Leite Neto
EJEden L. Carvalho Junior
Eden L. Carvalho Junior
Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability. Consequently, monitoring lightning activity is critical to mitigate its impact on lines with high outage rates. This study presents an autonomous lightning strike counter system utilizing a split-core Rogowski coil for non-invasive current measurement on transmission towers. The system combines the Rogowski coil with an active integrator circuit to reconstruct the incident current waveform from the coil voltage signal. A microcontroller-based processing unit records strike occurrences and classifies them by amplitude using predefined thresholds. Laboratory tests were carried out to evaluate the performance of the Rogowski coil and integrator circuit, validating the system accuracy in detecting current pulses associated with lightning strikes. Underway field tests will assess the sensor’s reliability during long-term autonomous operation on 345-kV transmission towers. The results demonstrate that the proposed system represents a practical and cost-effective solution for lightning monitoring in remote areas, contributing to enhanced data collection for engineering studies and improved reliability of electrical infrastructure.

1 October 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
Arthur Francisco AndradeArthur Francisco Andrade
Arthur Francisco Andrade
ECE.G. da Costa
E.G. da Costa
GLGeorge Lira
George Lira