4 March 2009 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RSRodrigo Hartstein Salim
Rodrigo Hartstein Salim
MRMariana Resener
Mariana Resener
AFAndré Darós Filomena
André Darós Filomena
KOKaren Rezende Caino de Oliveira
Karen Rezende Caino de Oliveira
Arturo BretasArturo Bretas
Arturo Bretas
In this paper, an extended impedance-based fault-location formulation for generalized distribution systems is presented. The majority of distribution feeders are characterized by having several laterals, nonsymmetrical lines, highly unbalanced operation, and time-varying loads. These characteristics compromise traditional fault-location methods performance. The proposed method uses only local voltages and currents as input data. The current load profile is obtained through these measurements. The formulation considers load variation effects and different fault types. Results are obtained from numerical simulations by using a real distribution system from the Electrical Energy Distribution State Company of Rio Grande do Sul (CEEE-D), Southern Brazil. Comparative results show the technique robustness with respect to fault type and traditional fault-location problems, such as fault distance, resistance, inception angle, and load variation. The formulation was implemented as embedded software and is currently used at CEEE-D's distribution operation center.

1 April 2011 in IET Generation, Transmission & Distribution
Verified
Journal Article
Closed access
RSR.H. Salim
R.H. Salim
KSK.C.O. Salim
K.C.O. Salim
Arturo BretasArturo Bretas
Arturo Bretas
In this study, further improvements regarding the fault location problem for power distribution systems are presented. The proposed improvements relate to the capacitive effect consideration on impedance-based fault location methods, by considering an exact line segment model for the distribution line. The proposed developments, which consist of a new formulation for the fault location problem and a new algorithm that considers the line shunt admittance matrix, are presented. The proposed equations are developed for any fault type and result in one single equation for all ground fault types, and another equation for line-to-line faults. Results obtained with the proposed improvements are presented. Also, in order to compare the improvements performance and demonstrate how the line shunt admittance affects the state-of-the-art impedance-based fault location methodologies for distribution systems, the results obtained with two other existing methods are presented. Comparative results show that, in overhead distribution systems with laterals and intermediate loads, the line shunt admittance can significantly affect the state-of-the-art methodologies response, whereas in this case the proposed developments present great improvements by considering this effect.

13 June 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
MAMuharrem Ayar
Muharrem Ayar
SOSerhat Obuz
Serhat Obuz
RTRodrigo D. Trevizan
Rodrigo D. Trevizan
Arturo BretasArturo Bretas
Arturo Bretas
HLHaniph A. Latchman
Haniph A. Latchman
Increasing deployment of information technologies and low-inertia renewable energy sources into smart grid fuel the uncertainties and reveal security and transient stability problems. Enhancing the stability margins of smart grids despite the cyber and physical disturbances emerges the need for cyber-aware robust controller design. Therefore, a distributed nonlinear robust controller is proposed to improve the transient stability margins of synchronous generators (SG) in the presence of excessive communication delay and cyber-physical disturbances. The proposed controller uses phasor measurement units to receive real-time measurements and actuates distributed storage systems to inject or absorb power in order to accelerate stabilization of frequency oscillations of SG following a disturbance. The communication dependency exposes time delay and cyber-security issues since latency is inherent and can be excessive during an attack such as denial of service. In addition, uncertainties in measurements challenge the stabilization process. Hence, the proposed controller is designed for robustness to delay and additive disturbances. A novel time delay compensation technique is developed to inject delay-free control signal into the closed-loop system. To guarantee that all tracking error signals are globally uniformly ultimately bounded, novel Lyapunov-Krasovskii functionals are used in the Lyapunov-based stability analysis. The simulation results validate the feasibility of the proposed control framework and robustness under cyber-physical practical limitations.

9 July 2008 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RSRodrigo Hartstein Salim
Rodrigo Hartstein Salim
KOKaren Rezende Caino de Oliveira
Karen Rezende Caino de Oliveira
AFAndré Darós Filomena
André Darós Filomena
MRMariana Resener
Mariana Resener
Arturo BretasArturo Bretas
Arturo Bretas
Power distribution automation and control are important tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagnetic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.

17 December 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LILeonardo Ulises Iurinic
Leonardo Ulises Iurinic
AHA. Ricardo Herrera-Orozco
A. Ricardo Herrera-Orozco
RFRenato Goncalves Ferraz
Renato Goncalves Ferraz
Arturo BretasArturo Bretas
Arturo Bretas
High-impedance fault location has always been a challenge for protection engineering. On the other hand, if this task is successfully realized, maintenance action could be performed in order to avoid potential injuries. For an effective protection scheme, high-impedance fault location should be performed, but a lack of research on this area is noted. This paper proposes a new analytical formulation for high-impedance fault location in power systems. The approach is developed in the time domain, considering a high-impedance fault model consisting of two antiparallel diodes. Using this model, the fault distance and parameters are estimated as a minimization problem. First, a linear least square-based estimator is applied without consideration of line capacitance. Second, a steepest descent-based estimator is proposed in order to consider the line capacitance. Studies were carried out with the IEEE 13 bus modeled in the Alternate Transients Program. Encouraging test results are found indicating the method's potential for real-life applications.