Increasing deployment of information technologies and low-inertia renewable energy sources into smart grid fuel the uncertainties and reveal security and transient stability problems. Enhancing the stability margins of smart grids despite the cyber and physical disturbances emerges the need for cyber-aware robust controller design. Therefore, a distributed nonlinear robust controller is proposed to improve the transient stability margins of synchronous generators (SG) in the presence of excessive communication delay and cyber-physical disturbances. The proposed controller uses phasor measurement units to receive real-time measurements and actuates distributed storage systems to inject or absorb power in order to accelerate stabilization of frequency oscillations of SG following a disturbance. The communication dependency exposes time delay and cyber-security issues since latency is inherent and can be excessive during an attack such as denial of service. In addition, uncertainties in measurements challenge the stabilization process. Hence, the proposed controller is designed for robustness to delay and additive disturbances. A novel time delay compensation technique is developed to inject delay-free control signal into the closed-loop system. To guarantee that all tracking error signals are globally uniformly ultimately bounded, novel Lyapunov-Krasovskii functionals are used in the Lyapunov-based stability analysis. The simulation results validate the feasibility of the proposed control framework and robustness under cyber-physical practical limitations.
In response to national and international carbon reduction goals, renewable energy resources like photovoltaics (PV) and wind, and energy storage technologies like fuel-cells are being extensively integrated in electric grids. All these energy resources require power electronic converters (PECs) to interconnect to the electric grid. These PECs have different response characteristics to dynamic stability issues compared to conventional synchronous generators. As a result, the demand for validated models to study and control these stability issues of PECs has increased drastically. This paper provides a review of the existing PEC model types and their applicable uses. The paper provides a description of the suitable model types based on the relevant dynamic stability issues. Challenges and benefits of using the appropriate PEC model type for studying each type of stability issue are also presented.
With the increase in penetration of renewable energy sources (RES), traditional inertia estimation techniques based purely on the number of online synchronous generators are increasingly unsuitable, ultimately leading towards suboptimal frequency control in the electric power grid. The stochastic nature of RES additionally makes the system inertia a time-varying quantity. Furthermore, the frequency and inertial response of power systems change drastically in multiarea power systems with interconnected tie-lines. Hence, it is important for state/parameter estimation (e.g., inertia) in multiarea systems, while ensuring communication between each of the areas. In this article, a client–server-based federated learning framework is used to estimate power system inertia in a multiarea system. Federated learning is a machine learning technique where multiple decentralized devices are trained with local data, and a global model is updated and redistributed by a central server by aggregating the trained weights of the decentralized devices, without exchanging the local data. Using local frequency measurements, obtained from the phase-locked loop of an energy storage system, the inertia at each of the areas can be estimated locally via offline training using convolutional neural networks (CNNs), whereas the CNN weights update in an online fashion. The framework, tested on a two-area power system, accurately estimated the inertia constant for both independent and identically distributed (IID) and non-IID data. Furthermore, the CNN-based method outperformed conventional neural network-based estimation techniques in terms of number of communication rounds and estimation accuracy.
This paper presents a literature review on current practices and trends on cyberphysical security of grid-connected battery energy storage systems (BESSs). Energy storage is critical to the operation of Smart Grids powered by intermittent renewable energy resources. To achieve this goal, utility-scale and consumer-scale BESS will have to be fully integrated into power systems operations, providing ancillary services and performing functions to improve grid reliability, balance power and demand, among others. This vision of the future power grid will only become a reality if BESS are able to operate in a coordinated way with other grid entities, thus requiring significant communication capabilities. The pervasive networking infrastructure necessary to fully leverage the potential of storage increases the attack surface for cyberthreats, and the unique characteristics of battery systems pose challenges for cyberphysical security. This paper discusses a number of such threats, their associated attack vectors, detection methods, protective measures, research gaps in the literature and future research trends.
25 August 2023 in IEEE Transactions on Industry Applications
Grid-scale battery energy storage systems (BESSs) are vulnerable to false data injection attacks (FDIAs), which could be used to disrupt state of charge (SoC) estimation. Inaccurate SoC estimation has negative impacts on system availability, reliability, safety, and the cost of operation. In this paper a combination of a Cumulative Sum (CUSUM) algorithm and an improved input noise-aware extended Kalman filter (INAEKF) is proposed for the detection and identification of FDIAs in the voltage and current sensors of a battery stack. The series-connected stack is represented by equivalent circuit models, the SoC is modeled with a charge reservoir model and the states are estimated using the INAEKF. The root mean squared error of the states' estimation by the modified INAEKF was found to be superior to the traditional EKF. By employing the INAEKF, this paper addresses the research gap that many state estimators make asymmetrical assumptions about the noise corrupting the system. Additionally, the INAEKF estimates the input allowing for the identification of FDIA, which many alternative methods are unable to achieve. The proposed algorithm was able to detect attacks in the voltage and current sensors in 99.16% of test cases, with no false positives. Utilizing the INAEKF compared to the standard EKF allowed for the identification of FDIA in the input of the system in 98.43% of test cases.
1 September 2020 in Electric Power Systems Research