Carsten auf der Heiden

Mr. Carsten auf der Heiden

Department of Cardiology, Pneumology and Angiology, Heinrich Heine University Düsseldorf, Düsseldorf, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2025 in Heart Rhythm
Verified
Journal Article
Open access
CHCarsten auf der Heiden
Carsten auf der Heiden
ABAlexandru Gabriel Bejinariu
Alexandru Gabriel Bejinariu
MKMalte Kelm
Malte Kelm
MSMaximilian Spieker
Maximilian Spieker
ORObaida Rana
Obaida Rana
Intravascular hemolysis with consecutive acute kidney injury (AKI) has been described after pulsed-field ablation (PFA) in atrial fibrillation (AF). This study aimed to evaluate the risk of intravascular hemolysis and AKI after PFA with different numbers and forms of applications. From May 2022 to August 2024, consecutive patients undergoing AF ablation were prospectively enrolled in 4 groups, including equally distributed numbers of patients undergoing PFA (pentaspline catheter) with 8 applications per vein (PFA-8), with 16 applications per vein (PFA-16), CardioFocus focal PFA, and radiofrequency ablation (RFA). Blood samples were collected immediately before and after the ablation, and on the following day to analyze hemolysis markers and indicators for AKI. A total of 200 patients (68.4 ± 10.8 years) could be included in the final analysis. The blood samples revealed a significant increase in total bilirubin and lactate dehydrogenase across all PFA modalities and RFA 24 hours after ablation compared with baseline levels. Potassium levels increased significantly in all PFA modalities immediately post-ablation as compared with baseline, followed by a return to approximately baseline after 24 hours. No significant potassium fluctuations were observed in RFA. Serum creatinine levels showed no significant increase in any PFA modality or RFA within the 24-hour assessment period. PFA using a multispline catheter with 8 and 16 applications per PV and focal PFA using CardioFocus (CardioFocus Inc., Massachusetts) platform showed no safety concerns with respect to hemolysis-induced AKI.

23 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SHStefan Hartl
Stefan Hartl
CHCarsten auf der Heiden
Carsten auf der Heiden
ABAlexandru Gabriel Bejinariu
Alexandru Gabriel Bejinariu
LCLukas Clasen
Lukas Clasen
AFAnna Füting
Anna Füting
HMHisaki Makimoto
Hisaki Makimoto
Esophageal thermal lesions following pulmonary vein isolation (PVI) for atrial fibrillation (AF) potentially harbor lethal complications. Radiofrequency (RF)-PVI using contact force-technology can reduce collateral damage. We evaluated the incidence of endoscopically detected esophageal lesions (EDEL) and the contribution of contact force to esophageal lesion formation without esophageal temperature monitoring. One hundred and thirty-one AF patients underwent contact force-guided RF-PVI. Contact force, energy, force-time-integral, and force-power-time-integral were adopted. During PVI at the posterior segment of the wide antral circumferential line, limits were set for energy (30 W), duration (30 s) and contact force (40 g). Ablations were analyzed postero-superior and -inferior around PVs. Endoscopy within 120 h identified EDEL in six patients (4.6%). In EDEL(+), obesity was less frequent (17% vs. 68%, p = 0.018), creatinine was higher (1.55 ± 1.18 vs. 1.07 ± 0.42 mg/dL, p = 0.016), and exclusively at the left postero-inferior site, force-time-integral and force-power-time-integral were greater (2973 ± 3267 vs. 1757 ± 1262 g·s, p = 0.042 and 83,547 ± 105,940 vs. 43,556 ± 35,255 g·J, p = 0.022, respectively) as compared to EDEL(−) patients. No major complications occurred. At 12 months, arrhythmia-free survival was 74%. The incidence of EDEL was low after contact force-guided RF-PVI. Implementing combined contact force-indices on the postero-inferior site of left-sided PVs may reduce EDEL.

27 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ABAlexandru Gabriel Bejinariu
Alexandru Gabriel Bejinariu
NANora Augustin
Nora Augustin
MSMaximilian Spieker
Maximilian Spieker
CHCarsten auf der Heiden
Carsten auf der Heiden
SAStephan Angendohr
Stephan Angendohr
ORObaida Rana
Obaida Rana
Background: The safety and efficacy of electrophysiological (EP) procedures using ultrasound (US) guidance are being increasingly studied. We investigated if a systematic workflow with ultrasound guidance (the US4ABL), comprising four steps (transesophageal echocardiography (TEE) for left atrial thrombus exclusion, US of the groin vessels to guide femoral access, TEE-aided transseptal puncture, and transthoracic echocardiography (TTE) for exclusion of pericardial tamponade after the procedure), reduces the number of complications and fluoroscopy duration and dose. Methods: A total of 212 consecutive patients underwent left-sided ablations using the US4ABL workflow and were compared to a group of 299 patients who underwent the same type of ablations using post-procedural TTE to exclude tamponade (standard group: venous and/or arterial access by palpation and fluoroscopy, and pressure guided transseptal puncture). Complications, procedural duration, fluoroscopy duration, and dose were compared. Results: The cohort included 511 patients (42% female); 43.8% of patients suffered from paroxysmal atrial fibrillation (AF), 35.4% presented with persistent AF, 10.7% underwent the procedure was for atrial tachycardia, and 10% of patients had premature ventricular contractions. The complication rate in the US4ABL group was lower compared to the standard group: 0 complications vs. 11 complications (3.7%, mainly vascular and pericardial), respectively (p = 0.005). The procedure times were lower in the US4ABL group (p < 0.01), whereas the fluoroscopy time and dose did not differ significantly. Conclusions: A fully ultrasound-guided (US4ABL) workflow for left atrial and ventricular electrophysiology procedures reduces the complication rate and the procedure time.

28 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAlexandru Gabriel Bejinariu
Alexandru Gabriel Bejinariu
NANora Augustin
Nora Augustin
MSMaximilian Spieker
Maximilian Spieker
CHCarsten auf der Heiden
Carsten auf der Heiden
SAStephan Angendohr
Stephan Angendohr
ORObaida Rana
Obaida Rana
Background: Three-dimensional (3D) mapping of the left atrium (LA) using multipolar high-density (HD) catheters plays a central role in contemporary LA ablation procedures, as accurate and efficient acquisition of anatomical and electrophysiological information is essential. This study benchmarks workflow efficiency during acquisition of a predefined complete HD LA map across four widely used multipolar HD catheter designs. The analysis focuses on efficiency metrics and does not aim to assess mapping quality, arrhythmia interpretation accuracy, or clinical outcomes. Methods: We analyzed 182 consecutive patients from an ongoing cohort undergoing LA procedures, including pulmonary vein isolation and complex LA ablations, using 3D mapping in accordance with current guideline recommendations. Four multipolar HD catheters were applied according to the respective 3D mapping systems: a basket catheter (Orion, Rhythmia), a grid catheter (HD Grid, EnSite X), a penta-spline catheter (PentaRay, Carto 3), and an octa-spline catheter (OctaRay, Carto 3). For each procedure, the time required for acquisition of a complete 3D LA map and the number of acquired points were systematically recorded. LA HD mapping speed was calculated by relating LA volume to the time required for complete map acquisition. Results: The study population had a mean age of 69 years, with a median CHA2DS2-VASc score of 3, indicating a cohort with a moderate thromboembolic risk profile. The median LA volume index (LAVI) was 34 mL/m2. Patients were distributed across four HD catheter groups, comprising 44 patients in the basket group, 29 in the grid group, 23 in the penta-spline group, and 86 in the octa-spline group. LA mapping speed differed significantly among the groups, with values of 3 mL/min in the basket group, 2.5 mL/min in the grid group, 3.1 mL/min in the penta-spline group, and the highest mapping speed observed in the octa-spline group at 5.9 mL/min. Conclusions: The octa-spline catheter was associated with a significantly higher LA mapping speed compared with other widely used HD catheters.