Yongfeng Cao

Yongfeng Cao

Auto-generated profile, based on publicly available information

Yongfeng Cao

School of Materials Science and Engineering and the Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YCYongfeng Cao
Yongfeng Cao
QZQiangsong ZHAO
Qiangsong ZHAO
YYYongqiang Ye
Yongqiang Ye
YXYongkang Xiong
Yongkang Xiong

4 January 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YCYongfeng Cao
Yongfeng Cao
WYWentuo Yang
Wentuo Yang
SWShuang Wang
Shuang Wang
SHShaoying He
Shaoying He
ZLZheng Liu
Zheng Liu
LXLe Xie
Le Xie
Continuum robots (CRs) have drawn increasing attention owing to their unique ability to operate in constrained environments. However, due to the deformability and compliant structures of CRs, parametric uncertainties and disturbances always exist in the CR system, which makes it a challenge to design high-performance controllers using conventional feedback control. In this article, we propose an error-driven active disturbance rejection control (ADRC) strategy that treats the internal uncertainty and external disturbance of the CR as a generalized disturbance and compensate for them. Furthermore, considering that the past input and output data from the control system can characterize the time-varying model of the CR, this article proposes an error-driven ADRC with input mapping method to further reduce the uncertainties and improve the control performance. The efficacy of the proposed method is verified through comparative simulations and experiments.

21 September 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YCYongfeng Cao
Yongfeng Cao
ZLZefeng Liu
Zefeng Liu
HYHailong Yu
Hailong Yu
WHWuzhou Hong
Wuzhou Hong
LXLe Xie
Le Xie
Owing to the curved and narrow pathway of the maxillary sinus, reaching blind regions using rigid instruments in the traditional method of treatment is difficult. In this article, a novel multisection continuum robot (CR) integrated with essential instruments and sensors is developed for the maxillary sinus surgery. Moreover, shape sensing is important for the control of the CR, but this is still a challenge due to the confined operating space. To track the spatial shape of the developed CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Simulations and experiments on a maxillary sinus phantom are conducted to test the ability of the CR to reach the blind regions. Different groups of experiments are performed to evaluate the performance of the shape reconstructions, including DTG sensor shape tests and CR shape tests in planar and spatial space. Experiments show a mean planar error of 0.23 mm (0.51%) and a mean spatial error of 0.61 mm (1.36%). The results demonstrate the effectiveness of the multisection CR shape sensing method suggested in this study.

12 September 2022 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
YCYongfeng Cao
Yongfeng Cao
FFFan Feng
Fan Feng
ZLZefeng Liu
Zefeng Liu
LXLe Xie
Le Xie
Due to the inherent deformability of continuum robots (CRs), closed-loop control strategies of CRs come with some challenges, including sensor integration within a limited dimension and uncertainties with the CR system. In this paper, to obtain the spatial shape information and tip position of a cable-driven CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Then, with the feedback information of the DTG sensor, a damped least-squares (DLS)-based closed-loop controller is implemented to improve the trajectory tracking performance of the CR. To verify the effectiveness of the proposed scheme, comparative experiments are performed.

25 October 2022 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
YCYongfeng Cao
Yongfeng Cao
YSYuxuan Shi
Yuxuan Shi
WHWuzhou Hong
Wuzhou Hong
PDPeidong Dai
Peidong Dai
XSXicai Sun
Xicai Sun
LXLe Xie
Le Xie

11 October 2021 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
WHWuzhou Hong
Wuzhou Hong
YZYuan Zhou
Yuan Zhou
YCYongfeng Cao
Yongfeng Cao
FFFan Feng
Fan Feng
ZLZefeng Liu
Zefeng Liu
LXLe Xie
Le Xie