Hao Yi

Hao Yi

Auto-generated profile, based on publicly available information

Hao Yi

School of Electrical Engineering, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2014 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
BLBaoquan Liu
Baoquan Liu
FZFang Zhuo
Fang Zhuo
YZYixin Zhu
Yixin Zhu
HYHao Yi
Hao Yi
A renewable energy-based dc micro-grid with hybrid energy storage, consisting of battery and ultracapacitor, is investigated. To achieve high penetration depth of renewable sources into the utility grid, a novel system operation strategy and the corresponding energy management method is proposed. In the operation strategy, the ultracapacitor unit works as the sole voltage source of the micro-grid to support the dc link in both connected and islanding mode. The micro-grid is controlled to deliver/absorb predefined amount of power to/from the utility grid during connected mode and zero during islanding mode. This design will certainly simplify the power dispatching algorithm of the power system and increase the possibility of including large quantities of micro-grids into the utility grid. The energy management method is dedicated to conducting the net power of the micro-grid effectively. The net power is separated into high- and low-frequency components. The high-frequency power is suppressed by the ultracapacitor automatically and the low frequency power is shared by the battery and an adjustment unit. A small-scale dc micro-grid structure with a single dc link is considered for investigation. MATLAB/Simulink simulation results are presented to validate the proposed system operation strategy and the energy management method.

4 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TZTianhua Zhu
Tianhua Zhu
FZFang Zhuo
Fang Zhuo
FZFangzhou Zhao
Fangzhou Zhao
FWFeng Wang
Feng Wang
HYHao Yi
Hao Yi
TZTong Zhao
Tong Zhao
The CLLC resonant converters are drawing more and more attention for their superiority in soft switching, wide output range and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this paper proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables and root mean square (RMS) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss and core losses of magnetic components. Besides, zero voltage switching (ZVS) conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18~25V/400V, 200W GaN based CLLC resonant converter prototype.

23 February 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HYHao Yi
Hao Yi
XWXiongfei Wang
Xiongfei Wang
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
FZFang Zhuo
Fang Zhuo
The latest research has pointed out that the phase-locked loop (PLL) plays an important role in shaping the impedance of grid-connected converters, yet most of the works so far merely focus on the synchronous reference-frame PLL. Alternatively, this letter presents the impedance analysis of the second-order generalized integrator frequency-locked loop (SOGI-FLL), which has been introduced for realizing grid synchronization in the stationary reference frame. The influences of the voltage perturbation on the estimated phase and further on the output current are revealed for the grid-connected converter using the SOGI-FLL. The frequency-coupling effect of the SOGI-FLL is also identified and verified in the experimental tests.

15 April 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Zhenxiong WangZhenxiong Wang
Zhenxiong Wang
FZFang Zhuo
Fang Zhuo
HYHao Yi
Hao Yi
JWJiaqi Wu
Jiaqi Wu
FWFeng Wang
Feng Wang
ZZZhirong Zeng
Zhirong Zeng
Inertia emulation in inverter control strategies benefits in improving dynamic frequency performance in microgrid. Therefore, some inverter control strategies introduce virtual inertia, and the corresponding performance is investigated. These strategies mainly focus on improving frequency dynamics from the perspective of inverter, while their dynamic influence to ac bus and the interaction among different inverters are still unclear. This paper aims to investigate the dynamic frequency performance of multiple generation units in both grid-connected and islanded mode considering inertia interaction. A transfer function model of paralleled inverters with emulated inertia is set up for theoretical analysis. With this model, frequency and phase response of ac bus is studied under several cases, which reveals the interactive frequency performance of voltage-controlled inverters. Furthermore, inertia interaction among different inverters is analyzed in detail, which indicates the reaction from grid to inverter. Consequently, the effectiveness and ineffectiveness of virtual inertia in improving frequency dynamics are demonstrated, which is practical and helpful for virtual inertia imitation in microgrid. Simulation and experimental results are provided to validate its effectiveness.

30 March 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
Zhenxiong WangZhenxiong Wang
Zhenxiong Wang
HYHao Yi
Hao Yi
FZFang Zhuo
Fang Zhuo
NLNian Lv
Nian Lv
ZMZekun Ma
Zekun Ma
HFHui Fan
Hui Fan
The active power control of increasing renewable energy resources is a growing concern. For example, solar energy exploitation is highly dependent on the central controller and other resources. Previous research has introduced some solutions for this problem, but the performance is usually unsatisfactory in power allocation, communication dependence, mode switch, and algorithm complexity. This article proposes a straightforward but effective strategy for the two-stage photovoltaic (PV) inverter, which uses the voltage-control method to adjust the PV inverter’s output power and match the load demand. Moreover, reference power tracking is used instead of traditional maximum power point tracking. The mode detection and switch strategies are proposed to solve the power shortage problem, making the PV inverter maintain the voltage-control method even in the power shortage state. Even without adequate support from other facilities, the proposed method can control the PV inverter to organize an islanded microgrid if PV arrays’ maximum power is larger than the load demands. Therefore, solar energy can further participate in grid support and ensure that the microgrid is more stable, robust, and economical. Finally, the proposed methods are verified in simulation and experiment.

1 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Zhenxiong WangZhenxiong Wang
Zhenxiong Wang
HYHao Yi
Hao Yi
FZFang Zhuo
Fang Zhuo
JWJiaqi Wu
Jiaqi Wu
CZChengzhi Zhu
Chengzhi Zhu
With the employment of power electronic converters, renewable energy resources introduce noticeable diversity into different generation units and dramatically change the characteristics of the supply side. Cooperation of different kinds of generation units in steady and dynamic states hence becomes important issues for grid integration. This paper studies transient active power circulation caused by parameter difference among different kinds of generation units, like synchronous generator and voltage-controlled power inverters. Parameter differences brought by power electronic inverters are analyzed, including capacity, inertia and grid-side inductance. Moreover, a simplified transfer function model is utilized for the detailed analysis, which reveals how the transient active power circulation is influenced by the parameter difference. The theoretical analysis is verified with both simulation and experiment. Consequently, some important conjoint influences of inertia, impedance and capacity difference are clarified, where the effectiveness and ineffectiveness of inertia and impedance imitation are concluded in transient active power allocation. Inertia and Impedance design that attenuates transient active power circulation is proposed in several certain situations for inverter cooperated with other generation units.