9 November 2015 in IEEE Transactions on Power Electronics
With increasing penetration of the renewable energy, the grid-tied PWM inverters need to take corresponding responsibilities for the security and stability of future grid, behaving like conventional rotational synchronous generator (RSG). Therefore, recognizing the inherent relationship and intrinsic differences between inverters and RSGs is essential for such target. By modeling the typical electromechanical transient of grid-tied PWM inverters, this paper first proves that PWM inverters and RSGs are similar in physical mechanism and equivalent in mathematical model, and the concept of static synchronous generator (SSG) is thereby developed. Furthermore, the comprehensive comparison between RSG and SSG is carried out in detail, and their inherent relation is built. Based on these findings, the rationality and feasibility of migrating the concepts, tools, and methods of RSG stability analysis to investigate the dynamic behaviors and stability issues of SSG is therefore confirmed. Taking stability issues as an example, the criteria of small signal and transient stability of a typical grid-tied PWM inverter is put forward to demonstrate the significance of the developed SSG model (including synchronizing coefficient, damping coefficient, inertia constant, and power-angle curve), providing clear physical interpretation on the dynamic characteristics and stability issues. The developed SSG model promotes grid-friendly integration of renewable energy to future grid and stimulates interdisciplinary research between power electronics and power system.
12 December 2014 in IEEE Transactions on Smart Grid
A renewable energy-based dc micro-grid with hybrid energy storage, consisting of battery and ultracapacitor, is investigated. To achieve high penetration depth of renewable sources into the utility grid, a novel system operation strategy and the corresponding energy management method is proposed. In the operation strategy, the ultracapacitor unit works as the sole voltage source of the micro-grid to support the dc link in both connected and islanding mode. The micro-grid is controlled to deliver/absorb predefined amount of power to/from the utility grid during connected mode and zero during islanding mode. This design will certainly simplify the power dispatching algorithm of the power system and increase the possibility of including large quantities of micro-grids into the utility grid. The energy management method is dedicated to conducting the net power of the micro-grid effectively. The net power is separated into high- and low-frequency components. The high-frequency power is suppressed by the ultracapacitor automatically and the low frequency power is shared by the battery and an adjustment unit. A small-scale dc micro-grid structure with a single dc link is considered for investigation. MATLAB/Simulink simulation results are presented to validate the proposed system operation strategy and the energy management method.
16 October 2012 in IEEE Transactions on Power Electronics
The conventional grid-connected photovoltaic (PV) inverter is controlled by a dual-loop control strategy in synchronous reference frame, and the controllers are designed for steady-state operating point based on the small signal model by neglecting the high-order and coupling terms. However, in an LCL filter, the coupling terms are complicated due to the dq transformation which will affect the dynamic performance. In this paper, an innovative simplified feedback linearization (SFL) control strategy is proposed for the PV inverter with the LCL filter, which offers satisfactory performance, particularly, in decoupling the control system, improving the dynamic performance, and enhancing the adaptability. Furthermore, the SFL controllers are simpler than the high-order tracking controllers used in conventional feedback linearization control. The detailed simplification process and accurate transfer functions for SFL control strategy have been presented, and the performance comparisons between the proposed SFL control strategy and the classical dual-loop method are carried out to show the characteristics of the proposed control algorithm. Finally, a laboratory prototype of a 150-kW PV inverter with the LCL filter has been implemented to test the feasibility and effectiveness of the proposed strategy. The proposed SFL control strategy can also be applied to a higher order system or other power converters.
26 June 2015 in IEEE Transactions on Power Electronics
Unlike the typical microgrid with a common ac bus, networked microgrid always suffers more serious reactive power sharing issues due to its complex inner structure. In such case, the system reactive power sharing error cannot be easily evaluated and eliminated. So, this paper proposes a wireless control strategy that employs optimized virtual impedance controllers and local load measurements for the reactive power sharing in networked microgrid. First, from the modeling of microgrid network, an estimation method for network reactive power sharing error is derived. Through the estimation method-based network feature analyses, corresponding design for virtual impedance controller is presented. Then, by introducing genetic algorithm, virtual impedance controller parameters of each distributed generation unit are optimized, which aims to minimize the microgrid global reactive power sharing error. The parameter optimization process is performed offline in microgrid configuration stage. By using these optimized virtual impedance controllers, the reactive power sharing performance of a networked microgird can be greatly improved. Finally, the accuracy of the estimation method is validated by MATLAB simulation results, and the feasibility of the proposed virtual impedance optimization method is verified through real power experiments.
4 March 2020 in IEEE Transactions on Power Electronics
The CLLC resonant converters are drawing more and more attention for their superiority in soft switching, wide output range and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this paper proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables and root mean square (RMS) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss and core losses of magnetic components. Besides, zero voltage switching (ZVS) conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18~25V/400V, 200W GaN based CLLC resonant converter prototype.
31 October 2014 in IEEE Transactions on Power Electronics
This paper proposes a novel three-phase phase-locked loop (PLL) algorithm, which focuses on the reforming of the primary signals before grid synchronization rather than improving the phase estimation methodologies. The unbalanced signals are reformed to balanced ones without damage to the phase angle, through which the negative sequence of the grid voltages is removed. This eliminates the estimation errors of conventional synchronous reference frame PLL and enhances its response speed with a higher bandwidth. The reforming process is supposed to be carried out at every zero-crossing point of the three-phase voltages and choose one phase as reference to balance the other two. Coefficients for the signal reforming are calculated at one zero-crossing point and updated until the next comes. In implementation, a certain phase is chosen as the reference all along and the reforming process will be suspended when it just crosses the zero line. This PLL algorithm has a fast and precise character to reform the three-phase grid voltages and is flexible for application. Under heavily distorted grid conditions, it can still perform effectively even with multiple zero-crossings. Comprehensive experimental results from a digital signal processor-based laboratory prototype are provided to validate the performance of this PLL algorithm.