Capacitive voltage transformer (CVT) transient transform characteristics destroy the linear relationship between output voltage and input voltage, leading to a sharp increase in measurement error. To address this issue, this article proposed an indirect method to design an infinite impulse response (IIR) filter to suppress the voltage oscillation amplitude caused by the CVT transient transformation characteristics. The method derives the CVT transfer function using the cascade form. Determining the compensating reactor frequency response curve, the intermediate transformer frequency response curve, and the oscillatory components below 50 Hz caused by ferromagnetic resonance as the design targets, IIR filters were designed to suppress the voltage oscillation amplitude. The proposed method’s effectiveness is verified by simulation in suppressing the voltage oscillation amplitude when transient response and ferromagnetic resonance occur. The simulation results show that the output voltage amplitude can be suppressed below 0.5 V after 0.48 s in the transient response, and the voltage oscillation amplitude caused by ferromagnetic resonance can be suppressed well under different short-circuit durations. This method also reduces the output voltage oscillation time and improves the CVT voltage measurement accuracy.

1 April 2022 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
LGLinyun Guo
Linyun Guo
QWQiong Wu
Qiong Wu
ZYZehong Yuan
Zehong Yuan
ZTZhaoyu Tao
Zhaoyu Tao
Distribution network grounding fault testing technology relies on a single criterion, which has a positioning blind area, resulting in large ranging error. In this paper, a grounding fault test technology for distribution network based on zero sequence power direction determination is proposed. The direction from the power supply side to the load terminal is specified as the positive direction of the network, the fault equivalent zero sequence current is modeled, and the high-frequency component of transient zero sequence current containing main fault characteristics is extracted. The fault line is determined based on the zero sequence power direction. For the fault line, the zero sequence power is less than zero, and the absolute value is much greater than the normal line, and the line selection device can select the line normally. The grounding fault test model of distribution network is established, and the fault current difference of each measuring point is calculated. When the difference is the smallest, it is identified as the fault location. The average ranging error of the test technology based on zero sequence power direction determination is 50.68m, which is 20.24m and 23.55m lower than that based on wavelet analysis and EMD. Therefore, it can accurately determine the fault line and has strong positioning advantages.