Chi Jin

Chi Jin

Auto-generated profile, based on publicly available information

Chi Jin

Energy Research Institute @ NTU, Nanyang Technological University, Singapore

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JWJunjun Wang
Junjun Wang
CJChi Jin
Chi Jin
Peng WangPeng Wang
Peng Wang
This paper presents a uniform control strategy for the bidirectional ac/dc interlinking converter (BIC) in hierarchical controlled hybrid microgrid. The uniform control strategy unifies different control structures for multifunctional BIC in terms of power management, ac and dc voltage support. With the unified control structure, various triggering mechanisms for BIC mode-switch are not compulsory in response to the relevant scenario changes in the power network. Therefore, the negative consequences, such as unsmooth transition and system collapse due to the inaccurate or slower mode switch, can be avoided. Moreover, the uniform control strategy is also applicable for the hierarchical controlled hybrid microgrid, whose control architecture is typically comprised of the centralized and decentralized levels. This enables the communication fault ride-through capability and the impact from the communication failures can thus be mitigated. To sum up the above two features, the proposed control strategy is able to provide a smooth operation for the BIC without control mode switch in the event of unintentional scenario changes in power or communication network. To verify the validity of the proposed uniform control strategy, the controller hardware-in-the-loop experimental results have been provided in this paper.

1 January 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PLPengfeng Lin
Pengfeng Lin
Peng WangPeng Wang
Peng Wang
CJChi Jin
Chi Jin
JXJianfang Xiao
Jianfang Xiao
XLXiaoqiang Li
Xiaoqiang Li
CZChuanling Zhang
Chuanling Zhang
For a hybrid ac/dc microgrid (MG), bidirectional interlinking converters (BICs) enable flexible power interactions between ac and dc subgrids. In each subgrid, power sharing among diversified sources has been effectively realized by droop controllers. These power sharing concepts can also be extended to BIC applications. This paper proposes a distributed power management strategy (DPMS) for multi-paralleled BICs in the hybrid MG to avoid the overstress of a single BIC. In this strategy, each BIC is assigned with a well-devised localized distributed controller (LDC) which generates the respective power reference for the BIC. By using the LDC, BICs are allowed to exchange information with one another in the distributed communication graph. The power interactions between ac and dc subgrids can be proportionally allocated to BICs based on their different power ratings in a full distributed manner. Then the system reliability and scalability are significantly improved. Meanwhile, accurate global power sharing among all ac and dc sources in the MG would be accordingly attained. Considering the communication time delay involved in BICs, a small signal model is derived to predict the maximum tolerable delay of the studied system. The validities of the proposed DPMS and delay stability analyses are verified by a controller hardware-in-loop experimental platform.

13 February 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PLPengfeng Lin
Pengfeng Lin
CJChi Jin
Chi Jin
JXJianfang Xiao
Jianfang Xiao
XLXiaoqiang Li
Xiaoqiang Li
DSDonghan Shi
Donghan Shi
PWPeng Wang
Peng Wang
It is renowned that the entire power system operation cost can be minimized when distributed generators (DGs) have the same incremental costs (ICs). This paper proposes a distributed control architecture for a hybrid ac/dc microgrid (MG) to realize global system economic operation. The architecture consists of two levels. In the first level, the ac frequency-IC (f ac -IC) droop and the dc bus voltage-IC (VdcIC) droop are employed in the ac and dc subgrids, respectively. With the synchronization of f ac and V dc , DG ICs in each subgrid will be equalized. However, the droops will inevitably cause deviations of f ac and V dc . Then a distributed control canonical form (DCCF), which provides a generalized method for f ac and V dc recoveries, is proposed in the second level. The DCCF allows DGs to communicate only with their neighbors, thus alleviating the communication burdens and enhancing the system scalability. Due to the presence of DCCF, f ac and V dc fluctuations, which naturally indicate subgrid loading conditions, are invisible. An original relative loading index (RLI) is proposed to extract the hidden loading condition of each subgrid even thoughfac and V dc are clamped as constants. By using RLI, the power reference of the bidirectional interlinking converter can be easily defined. All DG ICs the hybrid MG converge to the same value in the steady state. The feasibility and effectiveness of the proposed control architecture are verified by simulations and RT-LAB hardware in loop tests.

31 July 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PLPengfeng Lin
Pengfeng Lin
CZChuanling Zhang
Chuanling Zhang
JWJinyu Wang
Jinyu Wang
CJChi Jin
Chi Jin
Peng WangPeng Wang
Peng Wang
A multi-bus MG normally bridge multiple DC buses via a complex line impedance network. This intricate configuration together with tickling constant power loads (CPLs) may cause severe stability issues. For system stability improvement, a novel uniform nonsmooth control scheme (UNCS) is proposed. UNCS has the following four-fold advantages. 1) UNCS helps to express commonly used DC/DC converters, boost, buck and buck-boost, into a uniform model. The model substantially facilitates a uniform stabilizer design that accommodate the preceding three converters despite their typology differences. 2) UNCS assigns each converter based distributed generator (DG) with a composite large signal stabilizer comprising a nonsmooth observer and a nonsmooth controller. 3) The stabilizer also provides an additional control degree of freedom, a fine-tuning factor, to refine DG dynamic responses to meet high requirements for voltage and power qualities. 4) When numerous DGs with the proposed stabilizer assembles to build a multi-bus MG, the overall system large signal stabilization is autonomously attained without communication links, which is mathematically justified by Lyapunov stability analyses. As such, DGs are allowed to randomly plug in/out without worrying about vitiating system level stability. Experiments show that UNCS will stabilize the multi-bus MG in a large operation range.

7 July 2021 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
JWJunjun Wang
Junjun Wang
CDChaoyu Dong
Chaoyu Dong
CJChi Jin
Chi Jin
PLPengfeng Lin
Pengfeng Lin
Peng WangPeng Wang
Peng Wang
This paper proposed a distributed uniform control strategy for parallel bidirectional interlinking converters (BICs) to realize resilient operation of hybrid ac/dc microgrid (HMG). The proposed control strategy can coordinate the control objectives of BICs in different HMG operation modes with a uniform control structure, thus, to eliminate any mode transition detections. In normal condition, the power coordination between ac and dc subgrids can be achieved, while ac or dc voltage regulation can be maintained when main voltage source(MVS) fails in ac or dc subgrid. The coordination between parallel BICs relies on low-bandwidth neighbourhood communication. With the communication planned, accurate power sharing can be achieved. Communication fault ride-through capability is enabled with less power sharing accuracy. The system reliability and resilience of HMG under various fault conditions can be improved by the proposed control strategy. To verify the effectiveness of the proposed control strategy, the controller hardware-in-the-loop experiment results have been provide in this paper.

21 November 2019 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
PLPengfeng Lin
Pengfeng Lin
WJWentao Jiang
Wentao Jiang
PTPengfeng Tu
Pengfeng Tu
CJChi Jin
Chi Jin
CZChuanling Zhang
Chuanling Zhang
Peng WangPeng Wang
Peng Wang
Due to the different characteristics of energy storages (ESs), proper dynamic power allocation to ESs in a hybrid energy storage system (HESS) is of high significance. Integral droop (ID) controllers are applied to a class of ESs (denoted as ESHs) with high ramp rates but low energy density. V-P droops are adopted to regulate a class of ESs (referred to ESLs) with high energy density but limited response speeds. Then high/low frequency components of the load change could be autonomously responded by ESHs/ESLs. However, existing works only focus on small signal stabilization of HESS whose validity may only hold at certain equilibriums. To address this issue, an self-disciplined large signal stabilizing scheme is presented in this paper. A compound stabilizer comprising disturbance observers and a backstepping controller is delicately designed for ES-interfaced converter. The observers estimate the possible disturbances induced in the converter. Those estimations would be further neutralized by the backstepping controller which simultaneously guarantees converter system stability in the large signal sense. The overall system large signal stability can be, thereby, spontaneously realized with rigorous mathematical proofs by Lyapunov techniques. The effectiveness and feasibility of the compound stabilizer are verified by both simulations and hardware experiments.