Heinrich Wolf

Heinrich Wolf

Auto-generated profile, based on publicly available information

Heinrich Wolf

Fraunhofer EMFT, Munich, Germany

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2012 in Microelectronic Engineering
Verified
Journal Article
Closed access
PBP. Bělský
P. Bělský
RSR. Streiter
R. Streiter
HWH. Wolf
H. Wolf
SSS.E. Schulz
S.E. Schulz
OAO. Aubel
O. Aubel
TGT. Gessner
T. Gessner

1 October 2010 in Microelectronic Engineering
Verified
Journal Article
Closed access
HWH. Wolf
H. Wolf
RSR. Streiter
R. Streiter
MFM. Friedemann
M. Friedemann
PBP. Belsky
P. Belsky
OBO. Bakaeva
O. Bakaeva
TGT. Gessner
T. Gessner

1 December 2020 in Microelectronics Reliability
Verified
Journal Article
Closed access
PTPasi Tamminen
Pasi Tamminen
RFRita Fung
Rita Fung
RWRick Wong
Rick Wong
JWJohannes Weber
Johannes Weber
HWHeinrich Wolf
Heinrich Wolf

7 November 2019 in IEEE Transactions on Device and Materials Reliability
Verified
Journal Article
Closed access
JWJohannes Weber
Johannes Weber
RFRita Fung
Rita Fung
RWRick Wong
Rick Wong
HWHeinrich Wolf
Heinrich Wolf
HGHorst A. Gieser
Horst A. Gieser
LMLinus Maurer
Linus Maurer
This study analyzes the Electrostatic Discharge (ESD) susceptibility of a 28 nm high-speed CMOS Integrated Circuit (IC) for network applications (25 Gbps), showing a non-negligible failure rate in manufacturing after having passed Charged Device Model (CDM) qualification testing. A detailed inspection of each process step identified the press-fit assembly of charged through-hole connectors to be the root cause for ultra-fast discharges through the Printed Circuit Board (PCB) traces into the high-speed RF interface. Extended CDM tests of the high-speed ICs displayed a wide overlap of pass and fail not allowing for a clear conclusion regarding the CDM robustness. Only the single digit ps-resolution and precision of the highly reproducible test method Capacitively Coupled Transmission Line Pulsing (CC-TLP) allowed a conclusive sharp pass/fail transition at a certain peak current level. In combination with a 33/63 GHz single shot oscilloscope, it eventually identified the stress current slew rate to have a direct influence on the failure threshold, explaining the non-conclusive failure distribution of CDM. For this result, we had to increase the bandwidth of the CC-TLP setup, challenge the limits of today's metrology and test setups, and implement post measurement embedding/de-embedding techniques. By pushing the frontiers of today's ESD testing in the CDM domain, the outcome of this study should contribute to future standardization of CDM and CC-TLP.