Rubens Moreno de Freitas

Rubens Moreno de Freitas

Auto-generated profile, based on publicly available information

Rubens Moreno de Freitas

Instituto Latino-Americano de Pesquisa e Ensino Odontológico, Brasil

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2017 in Journal of Clinical Periodontology
Verified
Journal Article
Closed access
PDF file
CSCristiano Susin
Cristiano Susin
TFTiago Fiorini
Tiago Fiorini
JLJaebum Lee
Jaebum Lee
RFRubens Moreno de Freitas
Rubens Moreno de Freitas
HCHsien‐Chung Chiu
Hsien‐Chung Chiu
UWUlf M. E. Wikesjö
Ulf M. E. Wikesjö

1 January 2024 in Revista de Odontologia da UNESP
Verified
Journal Article
Open access
PDF file
CCCaroline Paixão Custódio
Caroline Paixão Custódio
RFRubens Moreno de Freitas
Rubens Moreno de Freitas
EJElcio Marcantonio Junior
Elcio Marcantonio Junior
RMRafael Scaf de Molon
Rafael Scaf de Molon
VGValdir Gouveia Garcia
Valdir Gouveia Garcia
Introduction The control of peri-implant biofilm plays a crucial role in the long-term success of dental implants. Topical treatment alternatives aimed at reducing or preventing biofilm accumulation around the implant's prosthetic components are critical for the success of the treatment. Objective The present study has clinically evaluated the effects of an oxygen-releasing mouthwash (BlueM®) over a 90-day period, following implant placement surgery. Material and method Inclusion and exclusion criteria allowed for the selection of participants who, after implant placement, were randomized into two groups: the control group, which used a 0.12% chlorhexidine mouthwash, and the BlueM group, which received the oxygen-releasing BlueM mouthwash. All participants were instructed to rinse twice daily for the first 10 days and once a day up to 30 days post-surgery. Clinical parameters were evaluated, including the visible plaque index (VP), marginal bleeding (MB), presence of calculus (PC), suppuration (SUP), mucositis (MU), and the extent of keratinized gingiva (KG). These data were collected at the time of suture removal (baseline). At 90 days postoperative, in addition to the aforementioned parameters, probing depth (PD), bleeding on probing (BOP), and the presence of peri-implantitis (PI) were evaluated. Result Nine patients were included in this study, with a total of 38 implants. The BlueM group demonstrated a reduction in MB and an even greater reduction in VP. The other assessed parameters showed similar results to those in the control group. Conclusion BlueM mouthwash has clinical benefits for biofilm control and gingival inflammation reduction.

1 January 2022 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
AMAndrew Sotirios Melenikiotis
Andrew Sotirios Melenikiotis
CVCamila Pereira Vianna
Camila Pereira Vianna
WCWaleska Caldas
Waleska Caldas
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan
RFRubens Moreno de Freitas
Rubens Moreno de Freitas
Background . This report presents a clinical case in which the CAD‐CAM technology was applied to optimize a complex partial rehabilitation with implant‐supported prostheses of a patient with several functional and aesthetic issues. Case presentation . A 40‐year‐old patient with several complaints due to the absence of multiple teeth and great dissatisfaction regarding his oral health was referred to a Dental College (Curitiba, Brazil). Guided surgery of 11 implants was planned. Digital flow and immediate loading protocol were applied. The patient was followed up for 2 years presenting good clinical and radiographic outcomes. Conclusions . The digital flow brought agility and precision to implant placement, immediate provisionalization added to satisfaction in the provisional phase, and CAD/CAM technology provided predictability and comfort to deliver the definite restorations.

1 January 2025 in Brazilian Dental Journal
Verified
Journal Article
Open access
RFRicardo Pasquini Filho
Ricardo Pasquini Filho
LKLeandro Eduardo Klüppel
Leandro Eduardo Klüppel
RFRubens Moreno de Freitas
Rubens Moreno de Freitas
LPLuis Violin Pereira
Luis Violin Pereira
Sílvio Roberto ConsonniSílvio Roberto Consonni
Sílvio Roberto Consonni
TDTatiana Deliberador
Tatiana Deliberador
This study aims to compare the effects of two distinct healing periods (4 and 8 months) on bone formation after maxillary sinus floor elevation surgeries using sintered bovine bone grafts through histological and histomorphometric analyses. Using a split-mouth design, fourteen participants with bilateral edentulism in the posterior maxilla were included and randomized into two groups with 4 months (Test Group - TG) and 8 months (Control Group - CG) of healing periods. After the healing period, bone samples were collected and subjected to histomorphometric analysis to quantify the percentages of newly formed bone, residual bone substitute, and soft tissues. Comparison between the groups was performed using the paired Student’s t-test (p<0.05). Twenty-eight maxillary sinus grafts were performed, and 54 dental implants were placed. Histological analysis revealed newly formed trabecular bone tissue in close contact with the bone substitute surface, with higher thickness observed in the CG. Collagen fibers in the CG exhibited greater birefringence, indicating increased thickness and organization compared to the TG. Histomorphometric analysis demonstrated a significant difference in the percentage of new bone formation between the CG (28.22 ± 6.29%) and TG (20.02 ± 5.97%; p<0,001), as well as in the percentage of residual bone substitute (TG: 39.12 ± 8.15%; CG: 31.65 ± 8.70%; p = 0.005). The proportion of soft tissues remained stable between groups. The 8-month healing period significantly increased bone tissue formation and maturation, suggesting that this interval optimizes the quality of grafted bone when using sintered bovine bone substitute.

1 March 2024 in Brazilian Journal of Implantology and Health Sciences
Verified
Journal Article
Open access
PDF file
SAStephanie Gomes Assunção Alves
Stephanie Gomes Assunção Alves
RFRubens Moreno de Freitas
Rubens Moreno de Freitas
ISIvete Aparecida de Mattias Sartori
Ivete Aparecida de Mattias Sartori
With technological advances in Dentistry, the search for more predictable, integrated, and agile planning and treatments increases. In Implantology, despite the digital flow being greatly encouraged, doubts remain about its technical success. Therefore, the aim of this clinical study was to evaluate the effectiveness of the full digital flow using two techniques for the fabrication of implant prostheses: with an abutment or direct to the implant, comparatively evaluating the time required for interproximal adjustment to adapt the crowns, occlusal adjustment, and the need to return to the laboratory for corrections. The sample consisted of 46 patients who underwent the installation of 75 implants, treated at the ILAPEO School of Dentistry surgical clinic. They were all over 18, of both sexes and received implants in single edentulous spaces that required rehabilitation with crowns. These patients were divided into two groups, with Group I (G1), comprising 27 patients (38 implants) who had received abutments at the time of surgery, and Group II (G2) comprising 28 patients (37 implants) who had received healing caps, with 9 patients in common in both groups. In G1, scan bodies adapted to the abutments were used. In G2, they were directly adapted to the implants. The cases were scanned and sent to the laboratory. When the crowns were installed, the prosthesis adjustment data was recorded (in seconds), as well as the need to return to the laboratory for adjustments and corrections. The data from the groups were compared using the Mann-Whitney non-parametric test. There were no statistical differences in terms of occlusal and proximal adjustment time. The need to return prosthetic work to the laboratory was compared between the groups using the chi-squared test. The GraphPad Prism 8 software (San Diego, CA, USA) was used for the statistical analysis, and all tests were applied at a significance level of 5%. Data analysis leads to the conclusion that digital flow made it possible to obtain satisfactory implant-supported single crowns in both groups. No differences were found between the two techniques regarding the time taken to adapt to the mouth and the need to return to the laboratory.

1 January 2024 in Revista de Odontologia da UNESP
Verified
Journal Article
Open access
PDF file
CRCarolina Pinheiro Rocha
Carolina Pinheiro Rocha
AZAna Daisy Zacharias
Ana Daisy Zacharias
EJElcio Marcantonio Junior
Elcio Marcantonio Junior
FFFlávia Noemy Gasparini Kiatake Fontão
Flávia Noemy Gasparini Kiatake Fontão
RMRafael Scaf de Molon
Rafael Scaf de Molon
RFRubens Moreno de Freitas
Rubens Moreno de Freitas
Introduction For a successful implant-supported rehabilitation and long-term maintenance in the anterior maxilla, it is imperative that the patient possesses adequate bone quality and quantity. Objective The aim of this study was to assess bone gain and stability following reconstruction with titanium mesh in the anterior region of the maxilla, irrespective of the biomaterial used for bone augmentation. Material and method Patient follow-up data were obtained from the Faculty's follow-up database. The focus was on individuals who had undergone rehabilitation in the anterior maxilla, previously augmented with bone grafts and growth factors in conjunction with titanium mesh. This retrospective cohort study involved at least 10 patients who met the inclusion criteria. Following an initial review of medical records, the eligible patients were invited for evaluation appointments. Result Out of 39 patients who had undergone guided bone regeneration surgery using titanium mesh, 12 met the inclusion criteria. As such, 17 sites suitable for the study were obtained, from which total of 276 tomographic measurements were then taken. There was a noticeable increase in thickness at all assessment levels relative to the bone crest apex, both immediately (T1) and six months post-surgery (T2), compared to baseline measurements (T0). Moreover, bone thickness tended to increase with the proximity to the apical level. Conclusion The use of titanium mesh combined with various biomaterials has yielded favorable outcomes in terms of augmenting bone volume.