Camila Pereira Vianna

Camila Pereira Vianna

Auto-generated profile, based on publicly available information

Camila Pereira Vianna

Curitiba, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2023 in Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
PDF file
RRRoberta Schroder Rocha
Roberta Schroder Rocha
CVCamila Pereira Vianna
Camila Pereira Vianna
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan
LPLuis Eduardo Marques Padovan
Luis Eduardo Marques Padovan
MSMaria Cristina Godoy Leme dos Santos
Maria Cristina Godoy Leme dos Santos

1 July 2021 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
GTGeninho Thomé
Geninho Thomé
WCWaleska Caldas
Waleska Caldas
CVCamila Pereira Vianna
Camila Pereira Vianna
CCCarolina Accorsi Cartelli
Carolina Accorsi Cartelli
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan
Objective: The aim of this study was to evaluate implant and prosthesis survival rates in full-arch rehabilitation supported by implants with platform-switched Morse taper connection submitted to immediate or delayed loading, after up to 5 years of follow-up. Material and Methods: Data was retrospectively collected from clinical records of patients who were treated by means of implant-supported full-arch rehabilitation. Survival rates of implants and prostheses were evaluated according to immediate or delayed loading. Results: The sample comprised 967 implants. Of those, 627 were submitted to immediate loading (IL) while 340 to delayed loading (DL). After a follow-up period of up to 5 years, the implant survival rate for IL was of 99.7% (622/627 implants) and 97.2% (333/340 implants) for DL. The overall implant survival rate was 98.8% (955/967 implants). Prosthesis survival rate was 100% (N = 178) for both groups. Significantly more implants in the DL group presented bone loss (p > 0.01), either greater or lower than 2 mm, during the follow-up period. Conclusion: Within their limits, the present results suggest that full-arch rehabilitation with platform-switched Morse taper connection implants can lead to surgical and prosthetic predictable outcomes. Moreover, immediate loading protocol seems to be a good option for the rehabilitation of fully edentulous patients, as it involves a shorter treatment time, which may lead to greater patient satisfaction.   Keywords Dental implants; Rehabilitation; Survival rate; Retrospective study.

1 August 2022 in Journal of Applied Oral Science
Verified
Journal Article
Open access
EJElcio Marcantonio Junior
Elcio Marcantonio Junior
ISIvete Aparecida de Mattias Sartori
Ivete Aparecida de Mattias Sartori
CVCamila Pereira Vianna
Camila Pereira Vianna
RRRoberta Schroder Rocha
Roberta Schroder Rocha
WCWaleska Caldas
Waleska Caldas
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan
This study aimed to retrospectively collect clinical data to evaluate the influence of possible risk factors on the long-term success of implant treatment with extra-narrow (2.9 mm diameter) implants in a daily dental practice setting. Data were collected from records of patients who received at least one extra-narrow implant from 2012 to 2017, regarding implant survival, prosthesis survival, patient characteristics, and implant characteristics. The association between the dependent variables “implant survival”, “prosthesis survival,” and “adverse events” related to patient and implant characteristics was statistically evaluated by chi-square tests. Moreover, implant and prosthesis survival were analyzed by Kaplan-Meier survival curves. The sample was constituted of 58 patients (37 women and 21 men) with a mean age of 54.8 years old (SD: 12.5), followed up for up to eight years. In total, 86 extra-narrow implants were placed within this sample. Four implants were lost, resulting in an implant survival rate of 95.3%. A total of 55 prostheses were inserted and only one (1.8%) was lost, resulting in a prosthesis survival rate of 98.2%. The mean implant and prosthesis survival time was, respectively, 7.1 years and 6.3 years, according to the Kaplan-Meier survival analysis. A correlation was found between smoking and implant loss, which makes implant loss eight times more likely to occur in smokers than non-smokers. A significant association was also found between prosthesis loss and previous need of prosthesis repair. However, it was not considered clinically relevant. No association was found between the occurrence of adverse events and later implant or prosthesis loss. High implant and prosthesis survival rates were found in the long term for treatment with extra-narrow implants. Moreover, a significant correlation between smoking and implant loss was observed.

4 December 2021 in Clinical Case Reports
Verified
Journal Article
Open access
PDF file
GTGeninho Thomé
Geninho Thomé
JUJean Uhlendorf
Jean Uhlendorf
CVCamila Pereira Vianna
Camila Pereira Vianna
WCWaleska Caldas
Waleska Caldas
SBSergio Rocha Bernardes
Sergio Rocha Bernardes
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan
This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection‐molded 2‐piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri‐implantitis signs, complete implant osseointegration, good marginal bone‐level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.

19 June 2021 in Odontology
Verified
Journal Article
Closed access
PDF file
LPLuis Eduardo Marques Padovan
Luis Eduardo Marques Padovan
DSDalton Suzuki
Dalton Suzuki
LKLeandro Eduardo Kluppel
Leandro Eduardo Kluppel
CVCamila Pereira Vianna
Camila Pereira Vianna
WCWaleska Caldas
Waleska Caldas
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan

24 August 2022 in Clinical Case Reports
Verified
Journal Article
Open access
GTGeninho Thomé
Geninho Thomé
CVCamila Pereira Vianna
Camila Pereira Vianna
WCWaleska Caldas
Waleska Caldas
SBSergio Rocha Bernardes
Sergio Rocha Bernardes
JUJean Uhlendorf
Jean Uhlendorf
LTLarissa Carvalho Trojan
Larissa Carvalho Trojan
Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability.