Kensuke Shinmura

Kensuke Shinmura

Auto-generated profile, based on publicly available information

Kensuke Shinmura

Department of Gastroenterology and Endoscopy, National Cancer Center Hospital East, Kashiwa, Japan

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in Digestive Endoscopy
Verified
Journal Article
Closed access
RSRyo Shimoda
Ryo Shimoda
TATakashi Akutagawa
Takashi Akutagawa
MTMichito Tomonaga
Michito Tomonaga
TMTatsuro Murano
Tatsuro Murano
KSKensuke Shinmura
Kensuke Shinmura
HIHiroaki Ikematsu
Hiroaki Ikematsu

20 December 2022 in Digestive Endoscopy
Verified
Journal Article
Open access
TSTaku Sakamoto
Taku Sakamoto
HIHiroaki Ikematsu
Hiroaki Ikematsu
NTNaoto Tamai
Naoto Tamai
YMYasuhiko Mizuguchi
Yasuhiko Mizuguchi
HTHiroyuki Takamaru
Hiroyuki Takamaru
YSYutaka Saito
Yutaka Saito
Objectives: We aimed to evaluate the efficacy of texture and color enhancement imaging (TXI), which allows the acquisition of brighter images with enhanced color and surface structure in colorectal polyp detection compared to white light imaging.Methods: Patients who underwent colonoscopy with repeated ascending colon observation using TXI and white light imaging between August 2020 and January 2021 were identified in three institutions. The outcomes included the mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and ascending colonic adenoma miss rate (Ac‐AMR). Logistic regression was used to determine the effects of the variables on the outcomes.Results: We included 1043 lesions from 470 patients in the analysis. The MAP, ADR, flat polyp detection rate, and Ac‐AMR in TXI and white light imaging were 1.5% (95% confidence interval 1.3–1.6%) vs. 1.0% (0.9–1.1%), 58.2% (51.7–64.6%) vs. 46.8% (40.2–53.4%), 66.2% (59.8–72.2%) vs. 49.8% (43.2–56.4%), and 17.9% (12.1–25.2%) vs. 28.2% (20.0–37.6%), respectively. TXI, age, withdrawal time, and endoscopy type were identified as significant factors affecting the MAP and the ADR using multivariate regression analysis.Conclusions: Our study indicates that TXI improve the detection of colorectal neoplastic lesions. However, prospective randomized trials are required to confirm these findings.

31 January 2020 in BMC Gastroenterology
Verified
Journal Article
Open access
PDF file
KSKensuke Shinmura
Kensuke Shinmura
HIHiroaki Ikematsu
Hiroaki Ikematsu
MKMotohiro Kojima
Motohiro Kojima
HNHiroshi Nakamura
Hiroshi Nakamura
SOShozo Osera
Shozo Osera
Tomonori YanoTomonori Yano
Tomonori Yano
Background: Monopolar instruments are generally used in colorectal endoscopic mucosal resection (EMR). Bipolar instruments have previously been reported to be as safe as monopolar instruments. We sought to compare the safety of the monopolar and bipolar snare and hemostatic forceps in an animal model. Methods: We created 5-mm, 10-mm, and 15-mm target lesions on an ex vivo porcine rectum. Two lesions of each size were resected via monopolar polypectomy (M-P), monopolar EMR (M-E), bipolar polypectomy (B-P), and bipolar EMR (B-E). We performed a pathological evaluation of the conditions of perforation and the effects of burning on the tissues. In addition, we burned the muscularis propria covered with submucosal layer using monopolar and bipolar hemostatic forceps and performed pathological evaluations. Results: Polypectomy and EMR were performed in a total of 24 target lesions. A perforation was found on histology in one case of M-P and one case of M-E after removing target lesions of 15 mm in diameter. There were no perforations during endoscopic resection using the bipolar snare. The thermal denaturation in B-P did not reach the muscularis propria layer regardless of the size of the target lesion. Although thermal damage after using monopolar hemostatic forceps was extensive, thermal denaturation was only seen on the surface of the submucosal layer when bipolar hemostatic forceps were used. Conclusions: Bipolar instruments cause less damage to the tissue than monopolar instruments. Our results also suggest that bipolar instruments may be safer than monopolar instruments in endoscopic procedures for colorectal lesions.

18 December 2024 in Endoscopy
Verified
Journal Article
Closed access
PDF file
KTKazunori Takada
Kazunori Takada
Naohisa YoshidaNaohisa Yoshida
Naohisa Yoshida
YHYoshikazu Hayashi
Yoshikazu Hayashi
DTDaichi Togo
Daichi Togo
SOShiro Oka
Shiro Oka
OGon behalf of the ABCD-J Working Group
on behalf of the ABCD-J Working Group
Background The effectiveness of prophylactic clip closure in reducing the risk of delayed bleeding after colorectal endoscopic submucosal dissection (ESD) is uncertain among patients on anticoagulants. We therefore aimed to assess this effectiveness using data from a large multicenter study. Methods We used the ABCD-J study database to analyze delayed bleeding among 34 455 colorectal ESD cases from 47 Japanese institutions. Delayed bleeding rates among the no/partial and complete closure groups were compared in patients on direct oral anticoagulants (DOACs) or warfarin. Propensity score matching was used for baseline characteristics to reduce the effects of selection bias. Results Overall, data from 1478 patients on anticoagulants who underwent colorectal ESD were examined. After propensity score matching, the complete and no/partial closure groups were compared in 212 patients on DOACs and 82 on warfarin. The complete closure group showed a significantly lower delayed bleeding rate in patients receiving DOACs (10.8 % vs. 5.2 %, absolute risk reduction [ARR] 5.7 %, P = 0.048) and warfarin (17.1 % vs. 6.1 %, ARR 11.0 %, P = 0.049). Additionally, complete closure significantly reduced the risk of delayed bleeding among patients taking DOACs for right-sided lesions (ARR 6.7 %, P = 0.04), whereas no risk reduction was observed for left-sided (P > 0.99) or rectal (P = 0.50) lesions. A similar trend was observed among patients on warfarin. Conclusions Prophylactic complete clip closure after colorectal ESD significantly reduced the delayed bleeding rate in patients receiving DOACs or warfarin. It should be performed after ESD, particularly for right-sided lesions.

9 August 2021 in Digestive Endoscopy
Verified
Journal Article
Closed access
HIHiroaki Ikematsu
Hiroaki Ikematsu
TMTatsuro Murano
Tatsuro Murano
KSKensuke Shinmura
Kensuke Shinmura

21 June 2024 in Digestive Endoscopy
Verified
Journal Article
Closed access
AIAtsushi Inaba
Atsushi Inaba
KSKensuke Shinmura
Kensuke Shinmura
HMHiroki Matsuzaki
Hiroki Matsuzaki
NTNobuyoshi Takeshita
Nobuyoshi Takeshita
MWMasashi Wakabayashi
Masashi Wakabayashi
Tomonori YanoTomonori Yano
Tomonori Yano