Vinay M. Pai

Vinay M. Pai

Auto-generated profile, based on publicly available information

Vinay M. Pai

Imaging Physics Lab, BBC/NHLBI/NIH, Bethesda, MD, USA

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MRMary M. Rodgers
Mary M. Rodgers
VPVinay M. Pai
Vinay M. Pai
RCRichard S. Conroy
Richard S. Conroy
Wearable sensor technology continues to advance and provide significant opportunities for improving personalized healthcare. In recent years, advances in flexible electronics, smart materials, and low-power computing and networking have reduced barriers to technology accessibility, integration, and cost, unleashing the potential for ubiquitous monitoring. This paper discusses recent advances in wearable sensors and systems that monitor movement, physiology, and environment, with a focus on applications for Parkinson's disease, stroke, and head and neck injuries.

22 July 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
SLSusanna K. Lynch
Susanna K. Lynch
VPVinay Pai
Vinay Pai
JAJulie Auxier
Julie Auxier
ASAshley F. Stein
Ashley F. Stein
EBEric E. Bennett
Eric E. Bennett
HWHan Wen
Han Wen
In grating-based x-ray phase sensitive imaging, dark-field contrast refers to the extinction of the interference fringes due to small-angle scattering. For configurations where the sample is placed before the beamsplitter grating, the dark-field contrast has been quantified with theoretical wave propagation models. Yet when the grating is placed before the sample, the dark-field contrast has only been modeled in the geometric optics regime. Here we attempt to quantify the dark-field effect in the grating-before-sample geometry with first-principle wave calculations and understand the associated particle-size selectivity. We obtain an expression for the dark-field effect in terms of the sample material’s complex refractive index, which can be verified experimentally without fitting parameters. A dark-field computed tomography experiment shows that the particle-size selectivity can be used to differentiate materials of identical x-ray absorption.

1 April 1999 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
Yousef HaikYousef Haik
Yousef Haik
VPVinay Pai
Vinay Pai
CCChing-Jen Chen
Ching-Jen Chen

3 June 2010 in Optics Letters
Verified
Journal Article
Open access
PDF file
HWHan Wen
Han Wen
EBEric E. Bennett
Eric E. Bennett
RKRael Kopace
Rael Kopace
ASAshley F. Stein
Ashley F. Stein
VPVinay Pai
Vinay Pai
We describe an x-ray differential phase-contrast imaging method based on two-dimensional transmission gratings that are directly resolved by an x-ray camera. X-ray refraction and diffraction in the sample lead to variations of the positions and amplitudes of the grating fringes on the camera. These effects can be quantified through spatial harmonic analysis. The use of 2D gratings allows differential phase contrast in several directions to be obtained from a single image. When compared to previous grating-based interferometry methods, this approach obviates the need for multiple exposures and separate measurements for different directions and thereby accelerates imaging speed.

1 January 2001 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
Yousef HaikYousef Haik
Yousef Haik
VPVinay Pai
Vinay Pai
CCChing-Jen Chen
Ching-Jen Chen

1 November 2012 in Investigative Radiology
Verified
Journal Article
Closed access
BDBenedicte M.A. Delattre
Benedicte M.A. Delattre
Magalie ViallonMagalie Viallon
Magalie Viallon
HWHongjiang Wei
Hongjiang Wei
YZYuemin M. Zhu
Yuemin M. Zhu
TFThorsten Feiweier
Thorsten Feiweier
PCPierre Croisille
Pierre Croisille
Objectives Diffusion-weighted imaging (DWI) and the introduction of the intravoxel incoherent motion (IVIM) model have provided a unique method for evaluating perfusion and diffusion within a tissue without the need for a contrast agent. Despite its relevance, cardiac DWI has thus far been limited by low b values because of signal loss induced by physiological motion. The goal of this study was to develop a methodology for estimating IVIM parameters of in vivo cardiac magnetic resonance imaging using an efficient DWI acquisition framework. This was achieved by investigating various acquisition strategies (principal component analysis [PCA] filtering and temporal maximum intensity projection [PCATMIP] and single trigger delay [TD]) and fitting methods. Material and Methods Simulations were performed on a synthetic dataset of diffusion-weighted signal intensity (SI) to determine the fitting method that would yield IVIM parameters with the greatest accuracy. The required number of b values to correctly estimate IVIM parameters was also investigated. Breath-hold DWI scans were performed for 12 volunteers to collect several TD values during diastole. Thirteen b values ranging from 0 to 550 s/mm2 were used. The IVIM parameters derived using the data from all the acquired TDs (PCATMIP technique) were compared with those derived using a single acquisition performed at an optimized diastolic time point (1TD). Results The main result of this study was that PCATMIP, when combined with a fitting model that accounted for T1 and T2 relaxation, provided IVIM parameters with less variability. However, an acquisition performed with 1 optimized diastolic TD provided results that were as good as those provided using PCATMIP if the R-R variability during the acquisition was sufficiently low (±5%). Furthermore, the use of only 9 b values (that could be acquired in 2 breath-holds), instead of 13 b values (requiring 3 breath-holds), was sufficient to determine the IVIM parameters. Conclusions This study demonstrates that IVIM is technically feasible invivo and reports for the first time the perfusion fraction, f, and the diffusion coefficients, D and D*, for the cardiac DWI of healthy volunteers. Motion-induced signal loss, which is the main problem associated with cardiac DWI, could be avoided with the combined use of sliding acquisition during the cardiac cycle and image postprocessing with the PCATMIP algorithm. This study provides new perspectives for perfusion imaging without a contrast agent and demonstrates that IVIM parameters can act as promising tools to further characterize microvascular abnormalities or dysfunction.