Lingyun Ren

Lingyun Ren

Auto-generated profile, based on publicly available information

Lingyun Ren

College of Chemical Engineering and Environment, Weifang University of Science and Technology, Weifang 262700, P. R. China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2016 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
LRLingyun Ren
Lingyun Ren
HWHaofei Wang
Haofei Wang
KNKrishna Naishadham
Krishna Naishadham
OKOzlem Kilic
Ozlem Kilic
AFAly E. Fathy
Aly E. Fathy
Ultra-wideband (UWB) pulse Doppler radars can be used for noncontact vital signs monitoring of more than one subject. However, their detected signals typically have low signal-to-noise ratio (SNR) causing significant heart rate (HR) detection errors, as the spurious harmonics of respiration signals and mixed products of respiration and heartbeat signals (that can be relatively higher than heartbeat signals) corrupt conventional fast Fourier transform spectrograms. In this paper, we extend the complex signal demodulation (CSD) and arctangent demodulation (AD) techniques previously used for accurately detecting the phase variations of reflected signals of continuous wave radars to UWB pulse radars as well. These detection techniques reduce the impact of the interfering harmonic signals, thus improving the SNR of the detected vital sign signals. To further enhance the accuracy of the HR estimation, a recently developed state-space method has been successfully combined with CSD and AD techniques and over 10 dB improvements in SNR is demonstrated. The implementation of these various detection techniques has been experimentally investigated and full error and SNR analysis of the HR detection are presented.

15 February 2017 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
LRLingyun Ren
Lingyun Ren
LKLingqin Kong
Lingqin Kong
FFFarnaz Foroughian
Farnaz Foroughian
HWHaofei Wang
Haofei Wang
PTPaul Theilmann
Paul Theilmann
AFAly E. Fathy
Aly E. Fathy
In this paper, we compare the performance of radar and optical (camera based) techniques in detecting vital signs such as respiratory rate (RR), heart rate (HR), and blood oxygen saturation (SpO 2 ). Specifically, we investigate the application of ultrawideband stepped-frequency continuous-wave radar and imaging photoplethysmography (iPPG) techniques to measure vital signs. The radar performance can be enhanced by using phase information of backscattered signal instead of its amplitude. On the other hand, the iPPG system can be enhanced by using more than one camera and utilizing very selective narrowband filters coupled with good illumination. In either system, use of advanced signal processing is required to improve accuracy. Generally, HR and RR can be accurately read by either microwave radar or optical techniques with 500 lx illumination level to have <; ±2% error up to 2 m distance between the subject and the system, but optical technique errors increase significantly to <; ±15% for <;200 lx. However, each system has its unique advantages as the radar can be used for seeing-through walls and optical technique is uniquely capable of measuring SpO 2 ).

2 March 2018 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
SNSabikun Nahar
Sabikun Nahar
TPTuan Phan
Tuan Phan
FQFarhan Quaiyum
Farhan Quaiyum
LRLingyun Ren
Lingyun Ren
AFAly E. Fathy
Aly E. Fathy
OKOzlem Kilic
Ozlem Kilic
An electromagnetic model for heart rate and respiration rate detection using the scattered fields of incident plane waves on a dielectric model of a human subject has been developed. The model approximates the torso by an equivalent homogenous dielectric layer, and utilizes an accelerated parallel version of the multi-level fast multipole algorithm to speed up the computation. Non-contact measurements using an ultra-wideband radar is utilized to experimentally validate the model. The model proved to be accurate for both heart rate and respiration rate detection within 5% error margin when compared to conventional contact sensor readings. The agreement between measured and simulated results is good for distances up to 3 m, and at various subject orientations with respect to the radar boresight. Meanwhile, in the presence of more than one subject, only slight degradation has been observed unless one subject is almost blocked by another. This accurate model would have broader impacts as it can be utilized to investigate various human activities and motion scenarios, and can be used, as well, to fine tune the signal processing techniques and radar system development.

8 May 2018 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
LRLingyun Ren
Lingyun Ren
NTNghia Tran
Nghia Tran
FFFarnaz Foroughian
Farnaz Foroughian
KNKrishna Naishadham
Krishna Naishadham
JPJean E. Piou
Jean E. Piou
AFAly E. Fathy
Aly E. Fathy
In this paper, ultra-wideband (UWB) Doppler radar signatures from walking human subjects are processed with the state-space method (SSM) to analyze compressed radar echoes for the first time. A new mathematical model is proposed to detect the human walking strides using UWB radar, while micro-Doppler (μ-D) features are extracted for gait analysis using short-time SSM (STSSM). To distinguish μ-D signatures of different subjects' body parts, the SSM used for the characterization of radar target signatures and sensor fusion is applied on a sliding short-time window to enhance the resolution of feature extraction from data collected on a dismount. This method of the application of SSM to sliding short-time data is validated with a full-wave electromagnetic (EM) simulation of a walking subject using the Boulic model that represents the human kinematics. An EM scattering model is then utilized to compare the performance of a short-time Fourier transform with STSSM. Experimental results show that STSSM can be successfully applied to identify multiple μ-D trajectories in real experimental data, thus demonstrating the capability to positively identify human motions (right foot, left foot, and torso) even in a low signal-to-noise ratio environment.

1 January 2016
Verified
Conference Paper
Closed access
RFRamzie A. Fathy
Ramzie A. Fathy
HWHaofei Wang
Haofei Wang
LRLingyun Ren
Lingyun Ren
RF and optical based photoplethysmography (PPG) have been recently developed for non-contact vital sign detection, due to their numerous advantages. In this paper, UWB radar, and camera-based monitoring are applied in vital sign detection and compared. In this paper, a mathematical signal model for the UWB Doppler radar, and another one for the camera-based photoplethysmography PPG are introduced. Vital signals have been recorded using both methods and compared. Capabilities and limitations of multiple subjects tracking have been demonstrated for multiple heartbeat detection. For validation, experimental results were compared to commercial contact sensors as well. Furthermore, the pros and cons of the Doppler radar and remote PPG in vital signs detection is discussed and summarized.

17 April 2018 in Electronics
Verified
Journal Article
Open access
PDF file
THTao Hu
Tao Hu
DCDan Chen
Dan Chen
FFFarnaz Foroughian
Farnaz Foroughian
LRLingyu Ren
Lingyu Ren
XCXulai Chen
Xulai Chen
JWJinjin Wei
Jinjin Wei
Because the traditional transmission line method treats electromagnetic waves as excitation sources and the cavity as a rectangular waveguide whose terminal is shorted, the transmission line method can only calculate shielding effectiveness in the center line of the cavity with apertures on one side. In this paper, the aperture coupling effect of different sides was analyzed based on vector analysis. According to the field intensity distribution of different transport modes in the rectangular waveguide, the calculation model of cavity shielding effectiveness in any position is proposed, which can solve the question of the calculation model of shielding effectiveness in any position in the traditional method of equivalent transmission methods. Further expansion of the equivalent transmission lines model is adopted to study the shielding effectiveness of different aperture cavities, and the coupling effect rule of the incident angle, the number of apertures, and the size of the cavity is obtained, which can provide the technical support for the design of electromagnetic shielding cavities for electronic equipment.