1 January 2013 in Computational and Mathematical Methods in Medicine
In computed tomography (CT), there are many situations where reconstruction has to be performed with sparse-view data. In sparse-view CT imaging, strong streak artifacts may appear in conventionally reconstructed images due to limited sampling rate that compromises image quality. Compressed sensing (CS) algorithm has shown potential to accurately recover images from highly undersampled data. In the past few years, total-variation-(TV-) based compressed sensing algorithms have been proposed to suppress the streak artifact in CT image reconstruction. In this paper, we propose an efficient compressed sensing-based algorithm for CT image reconstruction from few-view data where we simultaneously minimize three parameters: thenorm, total variation, and a least squares measure. The main feature of our algorithm is the use of two sparsity transforms—discrete wavelet transform and discrete gradient transform. Experiments have been conducted using simulated phantoms and clinical data to evaluate the performance of the proposed algorithm. The results using the proposed scheme show much smaller streaking artifacts and reconstruction errors than other conventional methods.
1 April 2009 in The FASEB Journal
The project represents a partnership between physical anthropology and human anatomy for the creation of 3D anatomical models for research and training. The models were created from post‐mortem X‐Ray CT scans of teaching cadavers. Initial steps involved identifying tissues, structures or regions of interest, and segmenting the structures of interest. Once a 3D model was rendered, further editing and refinement was required for 3D printing. CT scans were undertaken at the Health Sciences Centre, University of Manitoba. Analysis of the data was undertaken in the Bioanthropology Digital Image Analysis Laboratory (BDIAL), University of Manitoba. The data were edited and rendered using Materialise MIMICS and INUS Rapidform software. Physical models were created using a Z‐Corp Z406 3D printer. Preliminary input from students demonstrates the impact of the models for training and research, particularly the hand‐on nature of viewing models. Of particular benefit is the ability to reveal hidden structures at increased magnification, facilitating better understanding of the anatomical relationship of structures not easily visible in cadavers or photos. The use of 3D printing provides an innovative, on‐demand, pedagogical tool benefiting a variety of training needs, including physical anthropology, clinical and basic medical sciences. Funded by University of Manitoba; Canada Research Chairs Program.
1 January 2022 in Folia Morphologica
Arterial tortuosity describes variation via bending of the arterial wall and has been noted in several arteries throughout the body. Tortuous blood vessels can cause nerve compression, as well as present difficulties to surgeons and radiologists. Here we present an unusual case of multi-vessel arterial tortuosity discovered in 78-year-old Hispanic male cadaver, independent of systemic pathology. The left ulnar and right tibial arteries were dissected, and using calibrated digital callipers, their external and internal diameters were measured both at the origin site and at the site of greatest dilation. Both wall thickness and the number of inflection points were also measured. Six bends were noticed in the ulnar artery and its di-ameter measured 8.11 mm at its widest, with a wall thickness of 0.88 mm. On the lower extremity, the right tibial artery had three bends and its diameter measured 4.86 mm at its widest, with a wall thickness of 1.32 mm. This uncommon tortu-osity is not only more prone to laceration during surgery, but the bending and thickening can be mistaken for tumours. Finally, fluid dynamics can be altered, resulting in an impact on blood pressure in the extremities. Thus, raising awareness is crucial to prevent both symptoms and iatrogenic complications. (Folia Morphol 2022; 81, 3: 791-797)
8 February 2021 in Research Square
Anatomy, one of the cornerstones of medical education is often subject to testing in a practical manner utilizing tagged specimen-based exams. The design and production of 3D printed tags described here offers a unique ability to design in factors that support students with visual and learning disabilities. The lack of commercially available tags that can withstand the rigors and chemical exposure within this specific environment make the creation of this novel intervention vital to a great number of facilities. This report outlines the iterative process in creating a successful tag and the specifications needed to repeat the project. The success of these tags will impact students for years to come.
1 April 2013 in The FASEB Journal
We previously reported considerable intra‐element variation in osteocyte lacunar properties, with density differences up to 30% across a cross‐section of the male (20 yrs) femoral cortex related to the biomechanical axes. The purpose of this research was to determine whether this pattern of variation occurs in a larger sample. Anterior (A), posterior (P), medial (M) and lateral (L) blocks (2×2 mm) were prepared from the proximal femoral shaft of 7 healthy males aged 20–34 and synchrotron micro‐CT imaged. Average lacunar density (± sd) from the APML regions were 22,961 ± 1991, 28,264 ± 4186, 32,082 ± 7731 and 30,525 ± 1977 per mm3 of bone, respectively. Consistent with the pattern observed in the previous study, density was significantly different between the A and the L region (p<0.05). The density of the combined A and P regions was also lower (p=0.006) than that of the combined M and L regions. The differences in density were mirrored by shape differences; with the combined AP region having more elongate (p=0.004) and flattened (p=0.001) lacunae, than those of the ML region. The consistent appearance of this pattern of variation in a larger sample suggests considerable normal variation occurs in the lacunar properties of healthy young males. The underlying functional significance of the observed differences likely relates to localized variations in loading conditions as the pattern corresponds well with mechanical axes.
Grant Funding Source
: Saskatchewan Health Research Fund