7 August 2018 in IEEE Transactions on Industry Applications
In this paper, the theoretical analysis of the position estimation error in position-sensorless operation using pulsating square wave signal injection is presented. The purpose of this paper is to analyze the phenomenon that the position estimation performance varies depending on the injection frequency. Mathematical derivation supported by simulation and experimental results shows hat, in no load condition, the voltage distortion induces position estimation error with 3rd order harmonics if the frequency of injected square wave is the same to the switching frequency. While, if the frequency is a half of the switching frequency or heavier load condition in either injection frequency, the effect of non-ideal characteristics of inverter disappears and there is no 3rd harmonics in the position estimation error. Therefore, only the effect of cross-coupling inductance is reflected in the estimation error. As the result, the position estimation error appears in the form of 6th order harmonics due to the spatial harmonics of inductances, and the error is relatively small compared to the switching frequency injection case. The theoretical analysis was verified by simulation and experimental results.
23 November 2017 in IEEE Transactions on Industry Applications
In this paper, new model-based sensorless control methods are proposed which include independent estimations of position and speed errors and compatible position and speed estimators. Using the proposed position estimator, a unity transfer function can be achieved from the actual position to the estimated position, eliminating the effects of load disturbances. This implies that the position error would ideally be zero, even in a transient state. In addition, the effects of parameter and voltage synthesis errors on the steady-state position error are analyzed. Experimental results verify both the analysis and the effectiveness of the proposed methods under severe load disturbances such as speed transient (20,000 r/min/s) and load torque transient (10 p.u./s). With the proposed methods, position estimation errors are significantly reduced by more than 50% during speed and load torque transients at identical dominant-pole placements, verifying the enhanced tracking capability and robustness of the proposed methods against external load disturbances.
25 January 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
When a single-line-to-ground (SLG) fault occurs on the ac side of the modular multilevel converter (MMC) in an high-voltage direct-current transmission (HVDC) system, it results in the ac-side voltage sag and leads to an instantaneous reduction of the MMC power capacity. Thus, it calls for the fault ride through (FRT) strategy to coordinate two MMC stations in the HVDC system to protect the MMCs against the submodule (SM) capacitor overvoltage in case of the SLG fault. In the meantime, the HVDC system is expected to track the prefault active power as much as possible during the FRT to secure the power system stability. In this paper, a comprehensive FRT strategy is proposed, which is free of interstation communication. The proposed FRT strategy presents fast dynamic response, and it can prevent effectively the MMC SM-capacitor overvoltage and HVDC transmission line overvoltage. Moreover, the second-order voltage and current fluctuations in the HVDC transmission line caused by the grid unbalance are inherently avoided. Validity of the proposed strategy and its superiority over existing methods are demonstrated by simulation of a 200-kV, 400-MW cable-based HVDC system.
12 March 2019 in IEEE Transactions on Industry Applications
This paper presents an online MTPA control which considers both magnetic saturation and cross-magnetization effects of IPMSM. For IPMSM drives, especially in torque-controlled applications, torque accuracy and high efficiency operation are important issues. They can be dealt as a constrained optimization problem to satisfy both torque reference tracking and loss minimizing operation. In this paper, nonlinear simultaneous equations are derived from Lagrange multiplier method, which could be solved by numerical algorithms. Among them, Levenberg-Marquardt algorithm is employed to guarantee a robust calculation of optimal current references. It is optimized to alleviate calculation burden while maintaining the stability of the proposed algorithm. In addition, a torque reference limiter is implemented to satisfy a current limit in real time. The feasibility of the proposed method is verified under various operating conditions by simulation and experimental results. Through the proposed algorithms, accurate MTPA control is achieved under not only unsaturated but also highly-saturated operating conditions.