8 January 2019 in IEEE Transactions on Industrial Electronics
A novel control scheme is proposed in this paper for the sensorless control of interior permanent magnet synchronous machines (IPMSM) with the automatic tracking of the maximum-torque-per-ampere (MTPA) trajectory. Differing from the conventional method that the estimation of the rotor position and the tracking of MTPA trajectory are two separate processes, the proposed control scheme can achieve sensorless MTPA control of IPMSMs in one step by defining and constructing a proper virtual q-axis inductance to directly calculate the current space vector angle along the MTPA trajectory rather than the rotor position, which greatly simplifies the whole implementation process. Meanwhile, considering that the virtual q-axis inductance is changing with the machine parameters and the applied load, a simple signal processing technique based on the virtual high frequency signal injection is developed for the real-time and accurate acquisition of the virtual q-axis inductance. Furthermore, in order to ensure the reliability and stability of the proposed control scheme, the effective range of the virtual q-axis inductance is analyzed in detail. Finally, the experimental results on an IPMSM demonstrate the proposed control scheme can achieve the high-performance sensorless control with accurate MTPA self-tracking operation.
21 September 2021 in IEEE Transactions on Energy Conversion
Flux linkage estimation based on the voltage model has been widely employed in surface-mounted permanent magnet synchronous machine (SPMSM) sensorless drives due to its simple implementation. To deal with dc-offset and dc-drift problems, the pure integrator is modified as a programmable low pass filter (LPF)in practice. However, the estimation accuracy of the rotor position is affected by the adopted filter. Although the position deviation is compensated in steady-state based on the frequency characteristics of the filter, the compensation effect deteriorates during a dynamic process which severely degrades the sensorless control performance. In order to effectively tackle this problem, a novel compensation strategy based on the linear extended state observer (LESO) is proposed in this paper. With the constructed LESO in the estimated synchronous rotating reference frame, the position estimation error can be detected and compensated both in the steady and dynamic state. Moreover, the observer is enhanced to improve the estimation accuracy in linear acceleration and deceleration. Finally, the feasibility of the proposed method is verified under various operating conditions with a 5.5 kW SPMSM drive system.
5 December 2022 in IEEE Transactions on Power Electronics
Dead time is generally used to avoid the short circuit of the dc source, which causes harmonics in the output voltage and current of the voltage source inverters (VSIs). Based on an accurate harmonics calculation model of digital sinusoidal pulsewidth modulation, harmonics caused by dead time can be analyzed and calculated accurately. The proposed method obtains the compensation waveforms by the derived calculation module and detailed operation steps and then injects these into the sinusoidal reference voltage to eliminate the corresponding frequency harmonics caused by the dead time effect. The phase delay of the fundamental voltage caused by dead time is also considered. Moreover, this method avoids detecting the current polarity, affecting the compensation effect. Simulation and experimental results of the proposed method are presented to validate the effectiveness.
11 November 2010 in International Journal of Automation and Computing
Two model reference adaptive system (MRAS) estimators are developed for identifying the parameters of permanent magnet synchronous motors (PMSM) based on the Lyapunov stability theorem and the Popov stability criterion, respectively. The proposed estimators only need online measurement of currents, voltages, and rotor speed to effectively estimate stator resistance, inductance, and rotor flux-linkage simultaneously. The performance of the estimators is compared and verified through simulations and experiments, which show that the two estimators are simple, have good robustness against parameter variation, and are accurate in parameter tracking. However, the estimator based on the Popov stability criterion, which can overcome parameter variation in a practical system, is superior in terms of response speed and convergence speed since there are both proportional and integral units in the estimator, in contrast to only one integral unit in the estimator based on the Lyapunov stability theorem. In addition, the estimator based on the Popov stability criterion does not need the expertise that is required in designing a Lyapunov function.
1 December 2020 in IEEE Transactions on Power Electronics
This paper presents an accurate model of digitally controlled voltage source inverter (VSI) with dead-time effect. The impact of two nonlinear behaviors of digital sinusoidal pulse width modulation (DSPWM) and dead-time on the output waveform is analyzed in time domain. The problematic waveform with SPWM is displayed, which highlights the necessity of establishing a new model. In frequency domain, considering the dead time effect on the current, double-Fourier transform is used to give a harmonic expression without a current sign function. Furthermore, this avoids the error caused by the measurement of the current polarity, so the exact amplitude of each harmonic of the output voltage can be accurately calculated, which is important for eliminating specific harmonics and improving power quality. Moreover, the problem caused by the current zero-crossing is solved. The result of the analysis is verified by simulation and experiment on DSP and SIC platform. And the result shows that the harmonics and their amplitudes are in good agreement with our formula.
10 June 2022 in IEEE Transactions on Industrial Electronics
Cascaded H-bridge multilevel converter can generate high-voltage and high-power output with low harmonics. However, the error voltage caused by dead-time effect will distort the output waveform, which depends on the phase current polarity. Since the normal dead-time compensation method based on current sampling is often disturbed by sampling error and transmission delay, a novel current prediction method is proposed for dead-time compensation of cascaded H-bridge converter in this article. This method, based on phase-shift carrier pulsewidth modulation, reconstructs the switch pattern, and combined with the system model, can easily predict the phase currents. Excellent compensation performance can be obtained by dead-time compensation according to the predicted current. Simulation and experiments are built to validate the excellent performance of the proposed method applied to cascaded H-bridge converters.