5 December 2022 in IEEE Transactions on Power Electronics
Dead time is generally used to avoid the short circuit of the dc source, which causes harmonics in the output voltage and current of the voltage source inverters (VSIs). Based on an accurate harmonics calculation model of digital sinusoidal pulsewidth modulation, harmonics caused by dead time can be analyzed and calculated accurately. The proposed method obtains the compensation waveforms by the derived calculation module and detailed operation steps and then injects these into the sinusoidal reference voltage to eliminate the corresponding frequency harmonics caused by the dead time effect. The phase delay of the fundamental voltage caused by dead time is also considered. Moreover, this method avoids detecting the current polarity, affecting the compensation effect. Simulation and experimental results of the proposed method are presented to validate the effectiveness.
10 June 2022 in IEEE Transactions on Industrial Electronics
Cascaded H-bridge multilevel converter can generate high-voltage and high-power output with low harmonics. However, the error voltage caused by dead-time effect will distort the output waveform, which depends on the phase current polarity. Since the normal dead-time compensation method based on current sampling is often disturbed by sampling error and transmission delay, a novel current prediction method is proposed for dead-time compensation of cascaded H-bridge converter in this article. This method, based on phase-shift carrier pulsewidth modulation, reconstructs the switch pattern, and combined with the system model, can easily predict the phase currents. Excellent compensation performance can be obtained by dead-time compensation according to the predicted current. Simulation and experiments are built to validate the excellent performance of the proposed method applied to cascaded H-bridge converters.
14 November 2023 in IEEE Transactions on Industrial Electronics
The inherent resonance of $LCL$ filter tends to result in the grid-connected inverter system oscillating due to the variation of the grid impedance at the point of common coupling (PCC), so damping needs to be implemented to ensure the asymptotic stability. This article develops a novel and sensorless PCC voltage feedforward active damping (PCCVF-AD) control strategy, which includes a generic controller and a resonant compensation term, and then models the input admittance of current-controlled inverter system. Thereafter, based on the frequency-domain passivity theory, the stability criterion of system is transformed to the real part of the inverter input admittance, thus proposing a well-established PCCVF-AD controller design scheme. The proposed PCCVF-AD is designed to ensure the passivity of inverter input admittance in all frequencies, thereby achieving the plug-and-play capability that the inverter can be connected to the grid regardless of the grid impedance. The presented analysis results are verified by experiments.
21 April 2021 in IEEE Transactions on Vehicular Technology
In order to improve the transient and static performances of power following system in series hybrid electric vehicle (SHEV), this paper presents a delay-dependent MIMO robust control strategy. The control scheme coordinates the engine and the generator in the auxiliary power unit (APU) to reach the optimal speed and torque synchronously to output the required power. By the way of Pade approximation and multiple linear regression analysis, the delay time uncertainty in engine torque response is emphatically analyzed, which improves the accuracy of the engine torque model. The stability of the system is ensured theoretically by the Lyapunov Stability Theory and a sufficiently robust stability condition is established in terms of the linear matrix inequality (LMI). To avoid the problem of power reverse undershoot, a method of directly limiting the generator torque command is adopted, which is analyzed to not affect the stability of the system. The effectiveness and practicability of the proposed control strategy are demonstrated through numerical simulations and experiments.
10 June 2024 in IEEE Transactions on Power Electronics
Multiresonant controllers are widely used in the current control of grid-connected converters due to their accurate tracking of reference sinusoidal signals containing high harmonic counts. However, the performance of multiresonant controllers relies heavily on the suitability of the parameter design. In this paper, a generalized multiresonant controller that unifies various existing resonant controllers is proposed, which achieves the decoupling of the proportional terms, eliminates the need for online operation of trigonometric functions, and obtains a more extensive range of regulation capability. Furthermore, a new multioptimized parameter tuning method that considers several performance indexes is proposed to utilize the generalized resonant controller's performance fully. Finally, based on the proposed method, a generalized multiresonant controller is designed for $ {\bm {L}}$ -type and $ {\bm {LCL}}$ -type grid-connected inverters, respectively, demonstrating the universality of the proposed approach. Simulation and experimental results validate the effectiveness of the proposed method.
21 September 2021 in IEEE Transactions on Vehicular Technology
In the power control process of the range extender, both the engine and the generator are at risk of reaching the torque output limit. The limitation not only comes from the restriction of their own torque output capacity, but also comes from the additional constraints that are established to avoid power reverse undershoot. In order to improve the system performance under time-varying torque constraints, a real-time model predictive controller (MPC) that manipulates the torque commands of the engine and the generator to track the reference power is designed. Different from the traditional penalty function method, the quadratic function is taken as the penalty function in this paper, which greatly improves the efficiency of solving the optimal solution. Meanwhile, the steady-state torque command in the feasible region is taken as the extreme point of the quadratic penalty function, which avoids the penalty coefficient tending to infinity. By adjusting the penalty coefficients of different constraints, the overall optimal solution approaches the boundary of the active inequality constraints. And according to the Karush-Kuhn-Tucker (KKT) condition, it is proved that the optimal solution of the original problem can be obtained through iteration. The effectiveness and practicability of the proposed strategy are evaluated through numerical simulations on Simulink and experiments on a range extender.