Sebastian Thomas

Sebastian Thomas

Auto-generated profile, based on publicly available information

Sebastian Thomas

Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2022 in Metals
Verified
Journal Article
Open access
PDF file
QCQing Cao
Qing Cao
TPThunyaluk Pojtanabuntoeng
Thunyaluk Pojtanabuntoeng
MEMohsen Esmaily
Mohsen Esmaily
STSebastian Thomas
Sebastian Thomas
MBMichael Brameld
Michael Brameld
NBNick Birbilis
Nick Birbilis
Corrosion under insulation (CUI) is defined as any form of external corrosion that occurs on the underlying metal beneath insulated equipment, due to water ingress through the insulation layer. This type of corrosion is frequently observed in oil and gas production, where insulated piping is prevalent, and has historically remained a predominant materials integrity issue. The prediction and direct visualisation of CUI are challenging tasks because of the coverage of the insulation layer(s) and any external jacketing or cladding. Several factors, including the local/ambient environment, system design, and the piping installation process, can influence how CUI initiates and propagates. In this review, CUI background, CUI monitoring, and CUI mitigation strategies are discussed.

1 December 2016 in Heliyon
Verified
Journal Article
Open access
STSebastian Thomas
Sebastian Thomas
NONoemie Ott
Noemie Ott
RSRebecca F. Schaller
Rebecca F. Schaller
JYJodie A. Yuwono
Jodie A. Yuwono
PVPolina Volovitch
Polina Volovitch
NBNick Birbilis
Nick Birbilis
Atomic hydrogen (H) was introduced into steel (AISI 1018 mild steel) by controlled cathodic pre-charging. The resultant steel sample, comprising about 1 ppmw diffusible H, and a reference uncharged sample, were studied using atomic emission spectroelectrochemistry (AESEC). AESEC involved potentiodynamic polarisation in a flowing non-passivating electrolyte (0.6 M NaCl, pH 1.95) with real time reconciliation of metal dissolution using on-line inductively coupled plasma-atomic emission spectroscopy (ICP-OES). The presence of absorbed H was shown to significantly increase anodic Fe dissolution, as evidenced by the enhanced detection of Fe2+ ions by ICP-OES. We discuss this important finding in the context of previously proposed mechanisms for H-effects on the corrosion of steels.

27 March 2014 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
STS. Thomas
S. Thomas
ICIvan S. Cole
Ivan S. Cole
YGY. Gonzalez-Garcia
Y. Gonzalez-Garcia
MCMiao Chen
Miao Chen
MMM. Musameh
M. Musameh
NBNick Birbilis
Nick Birbilis

1 March 2020 in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
Verified
Journal Article
Closed access
QCQ. Cao
Q. Cao
MEM. Esmaily
M. Esmaily
RLR. L. Liu
R. L. Liu
NBN. Birbilis
N. Birbilis
STS. Thomas
S. Thomas
Corrosion under insulation (CUI) is a form of corrosion that occurs when moisture ingress through insulation and comes into contact with underlying metallic equipment. The rate of CUI depends on the ionic conductivity of the insulation, which, in turn, is related to the moisture distribution and metal ion concentration within the moist insulation. Metal ions are introduced into the moist insulation by metal corrosion and also from leaching from the insulation itself. These metal ions cause an increase in ionic conductivity through the moist insulation, thus influencing CUI. It was also observed that contact of steel with moist insulation, intrinsically increases its corrosion due to the formation of differential aeration cells resulting from variable oxygen diffusion arising from the non-homogenous packing of the insulation. Herein, the effect of such dissolved ions on CUI was studied. It was observed that the rate of CUI increases with time due to the release of metallic ions into the moist insulation.

23 August 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
SSS. H. Salleh
S. H. Salleh
NBN. Birbilis
N. Birbilis
MMM. Musameh
M. Musameh
KVK. Venkatesan
K. Venkatesan
STS. Thomas
S. Thomas
A solid-contact Mg2+ ion-selective microelectrode (ISME) usually consists of a carbon fiber coated with conducting polymer, such as electropolymerized 3, 4 ethylenedioxythiopene (PEDOT), in contact with the ion-selective membrane. PEDOT is typically electrochemically deposited onto the carbon fibers from rather expensive ionic liquid based dopants. Herein, Mg2+ ISMEs were assembled using a commercially available Mg2+ ionophore-containing solution and PEDOT electrochemically deposited from sodium p-toluenesulfonate, thus providing a simple and inexpensive method to develop Mg2+ ISMEs. The ISME fabricated by this procedure is successfully able to respond to Mg2+ ion concentrations arising from pure Mg during free corrosion and also galvanic corrosion (when Mg is coupled to pure iron).

13 October 2020 in Corrosion
Verified
Journal Article
Closed access
SSSiti Hawa Mohamed Salleh
Siti Hawa Mohamed Salleh
ZZZhuoran Zeng
Zhuoran Zeng
EME.A. McNally
E.A. McNally
NBNick Birbilis
Nick Birbilis
MMMustafa Musameh
Mustafa Musameh
BMBeth McNally
Beth McNally
Local scanning electrochemical microscopy (SECM), along with a scanning vibrating electrode technique (SVET), were used to spatially map anodic and cathodic regions in a complex assembly including a friction stir lap welded joint between two Mg-Al-Mn alloys, namely AM60 and AM30. The assembly investigated herein was comprised of the two base materials (AM60 and AM30) and a stir zone (SZ). The transitory electrochemical characteristics of the three regions were perceived from different electrochemical tests and have been correlated to their respective microstructures. Potentiometric and voltametric SECM performed on the assembly in 0.01 M NaCl revealed that during the first few minutes of exposure, AM60 and SZ regions act as dominant anodic regions in the assembly while after 2 h of exposure these regions transition to become cathodic relative to the AM30 region. Galvanic interaction between the different weld regions immersed in a significantly more conductive NaCl electrolyte was investigated by SVET. Under such conditions, filiform-like corrosion initiated, and propagated exclusively within the AM30 region, resulting in cathodic activation of the corroded surface. However, after approximately 5 h of exposure, the AM60 region preferentially dissolves following sufficient cathodic activation of the AM30 region.