Bo Sun

Bo Sun

Auto-generated profile, based on publicly available information

Bo Sun

School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology, Xi’an, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
BSBo Sun
Bo Sun
MBMarlin Ramadhan Baidillah
Marlin Ramadhan Baidillah
PDPanji Nursetia Darma
Panji Nursetia Darma
TSTomoyuki Shirai
Tomoyuki Shirai
KNKosei Narita
Kosei Narita
MTMasahiro Takei
Masahiro Takei
Objectives . The human skeletal muscle responds immediately under electrical muscle stimulation (EMS), and there is an immediate physiological response in human skeletal muscle. Non-invasive quantitative analysis is at the heart of our understanding of the physiological significance of human muscle changes under EMS. Response muscle areas of human calf muscles under EMS have been detected by frequency difference electrical impedance tomography ( fd -EIT). Approach . The experimental protocol consists of four parts: pre-training ( pre ), training ( tra ), post-training ( post ), and relaxation ( relax ) parts. The relaxation part has three relaxation conditions, which are massage relaxation (MR), cold pack relaxation (CR), and hot pack relaxation (HR). Main results . From the experimental results, conductivity distribution images σ p ( p means protocol = pre , tra , post , or relax ) are clearly reconstructed by fd -EIT as response muscle areas, which are called the M 1 response area (composed of gastrocnemius muscle) and the M 2 response area (composed of the tibialis anterior muscle, extensor digitorum longus muscle, and peroneus longus muscle). A paired samples t -test was conducted to elucidate the statistical significance of spatial-mean conductivities 〈 σ p 〉 M 1 and 〈 σ p 〉 M 2 in M 1 and M 2 with reference to the conventional extracellular water ratio β p by bioelectrical impedance analysis . Significance . From the t -test results, 〈 σ p 〉 M 1 and 〈 σ p 〉 M 2 have good correlation with β p . In the post-training part, 〈 σ post 〉 and β post were significantly higher than in the pre-training part ( n = 24, p < 0.001). The relax–pre difference ratios of spatial-mean conductivity Δ〈 σ relax–pre 〉 and the relax–pre difference ratios of extracellular water ratio Δ β relax–pre in both MR and CR were lower; on the contrary, the Δ〈 σ relax–pre 〉 and Δ β relax–pre in HR were significantly higher than those in post–pre difference ratios of spatial-mean conductivity Δ〈 σ post–pre 〉 ( n = 8, p < 0.05). The reason for the changes in 〈 σ p 〉 M 1 and 〈 σ p 〉 M 2 are caused by the changes in muscle extracellular volumes. In conclusion, fd -EIT satisfactorily evaluates the effectiveness of human calf muscles under EMS.

2 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PSPrima Asmara Sejati
Prima Asmara Sejati
BSBo Sun
Bo Sun
PDPanji Nursetia Darma
Panji Nursetia Darma
TSTomoyuki Shirai
Tomoyuki Shirai
KNKosei Narita
Kosei Narita
MTMasahiro Takei
Masahiro Takei
Multi-node electrical impedance tomography ( mn EIT) throughout whole-body electrical muscle stimulation ( wb EMS) has been proposed for the simultaneous imaging of muscle compartments response. mn EIT has two characteristics which are 1) network hardware for synchronized measurement in multi-node simultaneously and 2) nodal fast Fourier transform (FFT) for cancelling time-varying noise. By mn EIT, the muscle compartments response in the upper arm and thigh of eight healthy subjects are imaged throughout wb EMS under four voltage intensity levels. According to the reconstructed images of conductivity distribution σ in prior training and throughout wb EMS, the conductivity distribution trend of the upper arm and thigh are boosted along with the rise of wb EMS voltage intensity. As the hardware error evaluation, the normalized spatial-mean impedance error ε f of mn EIT is relatively higher in the increase of frequency while the average error 〈ε〉 is 7. 521% respectively. Here our mn EIT has the best result at ε f <〈ε〉 which occurred at f ≤ 2500 Hz that covers the frequency selection f 1 = 500 Hz and f 2 = 1000 Hz to obtain the best visualization of conductivity distribution σ. Meanwhile, based on the Pearson correlation as the statistical evaluation, the mn EIT has a relatively high accuracy value at the upper arm r arm =0.9391 and thigh r thigh =0.894.

30 July 2022 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
BSBo Sun
Bo Sun
TZTong Zhao
Tong Zhao
LLLu Li
Lu Li
ZWZhilong Wang
Zhilong Wang
PSPengzhao Sun
Pengzhao Sun
CPCong Peng
Cong Peng

17 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
QDQi Deng
Qi Deng
JHJie He
Jie He
CZChengjun Zhu
Chengjun Zhu
HWHao Wang
Hao Wang
KLKai Liu
Kai Liu
Jiafeng YaoJiafeng Yao
Jiafeng Yao
Visualization of breast tumor with three-dimensional Bioelectrical Impedance Spectroscopic Tomography (3D-BIST) is proposed to identify the position, size, benignity and malignancy of breast tumor. Firstly, to visualize in three-dimensions, a conical sensor is developed based on the actual shape of the breast. Secondly, to confirm the feasibility of the proposed method, finite element simulation is employed. The influence of different impedance spectroscopy data acquisition methods (0-skip, 1-skip and 3-skip) and different classifiers (Linear-SVM, RBF-SVM and KNN) on the classification results is explored in the simulation. The simulation results show that the 3D-BIST method allows visualization of breast tumor types; the image correlation coefficient of imaging results at each position is larger than 0.7 when the breast tumor diameter d ≥ 6 mm; the best acquisition method for impedance spectroscopy data is 3-skip acquisition; the best classifier is Linear-SVM classifier. The accuracy of the verification set calculated by 5-fold cross-validation achieved 93.5 %. The accuracy of identifying benign and malignant breast tumors with d ≥ 8 mm is exceeded 89.0 % on the test set. Finally, the proposed method was experimentally validated by using three kinds of biological tissues in place of normal breast tissue, benign breast tumor and malignant breast tumor. In conclusion, the 3D-BIST method enables three-dimensional visualization of breast tumors and identification of breast tumor types. The proposed method has the advantages of non-invasive and non-radiation, which is expected to be applied to the detection of breast tumors.

1 September 2021 in Physiological Measurement
Verified
Journal Article
Closed access
BSBo Sun
Bo Sun
PDPanji Nursetia Darma
Panji Nursetia Darma
TSTomoyuki Shirai
Tomoyuki Shirai
KNKosei Narita
Kosei Narita
MTMasahiro Takei
Masahiro Takei
Objectives . The electrical-tomographic imaging has been achieved for exploring differential tendency of physiological-induced conductive response in calf muscle compartments during voltage intensity change of electrical muscle stimulation ( vic -EMS). Approach . In the experiments, the differential tendency of conductivity distribution images σ during vic -EMS were clearly imaged as three responsive muscle compartments, which are called M 1 compartment composed of gastrocnemius muscle, M 2 compartment composed of tibialis anterior, extensor digitorum longus, and peroneus longus muscles, and M 3 compartment composed of soleus muscle. Main results . The differential tendency of spatial-mean conductivity 〈 σ 〉 M 1 is the same as the differential tendency of venous blood flow velocity v bl and blood lactate concentration C bl during vic -EMS by the increased tendency of spatial-mean conductivity difference Δ〈 σ 〉 M 1 , venous blood flow velocity difference Δ v bl and blood lactate concentration difference Δ C bl . The 〈 σ 〉 M 1 is increased with the increase of voltage intensity from 〈 σ pre 〉 M 1 = 0.142 [-] to 〈 σ l 14 〉 M 1 = 0.442 [-] ( pre : pre-training, l 14: voltage level during vic -EMS l = 14) by Δ〈 σ l 14- pre 〉 M 1 = 204.2% ( n = 16, p < 0.01). Correspondingly, the v bl and C bl are increased with the increase of voltage intensity by Δv bl l 14- pre = 1480.5% ( n = 16, p < 0.01) and Δ C bl l 14- pre = 230.1% ( n = 16, p < 0.01) respectively. Significance : The reason for the differential tendency of increase in < σ > M 1 suggests an increase in muscle extracellular volumes during vic -EMS due to the co-effect of venous blood flow velocity and blood lactate metabolism. Based on the conductivity second-order difference images ∂ 2 σ M 1 φ ∂ φ 2 φ and spatial-mean conductivity second-order difference ∂ 2 σ M 1 φ ∂ φ 2 φ , optimum voltage intensity φ OVI is discussed among sixteen volunteer subjects, which increased with a thicker subcutaneous fat layer.

8 March 2025 in Measurement
Verified
Journal Article
Closed access
ZLZhiwei Li
Zhiwei Li
YWYang Wu
Yang Wu
TXTiecheng Xu
Tiecheng Xu
JRJiajuan Ren
Jiajuan Ren
KLKai Liu
Kai Liu
Jiafeng YaoJiafeng Yao
Jiafeng Yao