Masahiro Takei

Masahiro Takei

Auto-generated profile, based on publicly available information

Masahiro Takei

Graduate School of Engineering, Chiba University

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Chao TanChao Tan
Chao Tan
SLShuhua Lv
Shuhua Lv
DFDong Feng
Dong Feng
MTMasahiro Takei
Masahiro Takei
Image reconstruction is a key problem for Electrical Resistance Tomography (ERT). Because of the soft-field nature and the ill-posed problem in solving inverse problem, traditional image reconstruction methods cannot achieve high accuracy and the process is usually time consuming. Since deep learning is good at mapping complicated nonlinear function, a deep learning method based on Convolutional Neural Network (CNN) is proposed for image reconstruction of ERT. To establish the database, 41122 samples were generated with numerical simulations. 10- fold cross validation was used to divide all samples into training set and validation set. The network structure was based on LeNet, and refined by applying dropout layer and moving average. After 346 training epochs, the Image Correlation Coefficient (ICC) on validation set was 0.95. When white Gaussian noise with a signal-to-noise ratio of 30, 40, and 50 were added to validation set, the ICC was 0.79, 0.89 and 0.93 respectively, which proved the anti-noise capability of the network. The reconstruction results on samples which have more inclusions, different conductivity and other shapes explained the network has good generalization ability. Furthermore, experimental data from a 16-electrode industrial ERT system was used to compare the accuracy of the proposed model with some typical reconstruction methods. Results show that the proposed CNN method has better reconstruction results than LBP, Tikhonov and Landweber.

15 March 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Jiafeng YaoJiafeng Yao
Jiafeng Yao
MTMasahiro Takei
Masahiro Takei
This paper reviews the latest development and emerging technologies on the application of process tomography to multiphase flow measurement in industrial and biomedical fields. In the industrial applications, electrical resistance tomography and electrical capacitance tomography are popularly applied in multiphase flow measurement dependent on the electrical properties of the objects. In particular, applications to circulating fluidized bed, trickle-bed reactor and temperature measurement are discussed. In the biomedical applications, in most cases, measurement is conducted in a static condition. Two latest applications in flowing condition are reviewed, which are thrombus detection in blood flow and cell sensing with a microfluidic device. Finally, the challenges to process tomography for multiphase flow measurement on industrial and biomedical applications are addressed.

17 April 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ZJZhupeng Jiang
Zhupeng Jiang
Jiafeng YaoJiafeng Yao
Jiafeng Yao
LWLi Wang
Li Wang
HWHongtao Wu
Hongtao Wu
JHJingshi Huang
Jingshi Huang
MTMasahiro Takei
Masahiro Takei
A portable electrochemical impedance spectroscopy (EIS) system has been developed based on FPGA for bio-detection. FPGA is a programmable signal processing chip, which cooperates with DAC module to generate the sweep excitation signal, controls ADC module to perform dual channel acquisition of voltage of a peripheral circuit, performs FFT and parameter calculation and transmits the result to PC for data processing. Based on FPGA internal programming, the system greatly reduces the size and achieves a single multi-frequency measurement, which enhances integration and portability of the system. The measurements of the electrical equivalent circuit by using the EIS system is compared with a high-precision commercial ZX70A impedance analyzer in the range of limited frequency of 100 Hz - 500 kHz. The result shows that the maximum relative error of amplitude and the maximum absolute error of phase are 2.42% and 0.936°, respectively. Finally, the EIS system is used to measure electrical impedance change during egg heating. The result shows that the impedance amplitude of egg decreases linearly with the increase of heating time and electrical characteristics of raw eggs and heated eggs are significantly different. These results verified that the developed EIS system achieve portable high-precision measurement of biological tissue.

31 May 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MBMarlin Ramadhan Baidillah
Marlin Ramadhan Baidillah
AIAl-Amin Saichul Iman
Al-Amin Saichul Iman
YSYue Sun
Yue Sun
MTMasahiro Takei
Masahiro Takei
An electrical impedance spectro-tomography consists of a quasi-adjacent sensing method and a frequency-time difference imaging for relatively complex dielectric object monitoring has been proposed. A quasi-adjacent sensing method is designed to measure an electrical impedance spectroscopy based on four-wire measurement technique at the multi-electrodes electrical impedance tomography sensor. A frequency-time difference imaging for spatial distribution monitoring is needed, as the electrochemical reaction incur during the short time meanwhile the spatial geometry tends to be constant. An artificial set of phantoms were made and the proposed technique was capable to show the Cole-Cole parameters as a dielectric relaxation model on each measurement pair. Compare with the adjacent method, using the quasi-adjacent method show Re(Z) is two times higher, Imag(Z) is ten times higher, and a higher and homogeneous sensitivity map area are 60% wider. A negative resistance at high-frequency measurement also can be eliminated successfully by using the proposed method.

30 October 2018 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
Jiafeng YaoJiafeng Yao
Jiafeng Yao
GZGuiping Zhu Zhu
Guiping Zhu Zhu
TZTong Zhao
Tong Zhao
MTMasahiro Takei
Masahiro Takei

9 September 2011 in Measurement Science and Technology
Verified
Journal Article
Closed access
GSGhali Venkat Subbarao
Ghali Venkat Subbarao
RMRavibabu Mulaveesala
Ravibabu Mulaveesala
MTM Takei
M Takei