Jan C. T. Eijkel

Jan C. T. Eijkel

Auto-generated profile, based on publicly available information

Jan C. T. Eijkel

BIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Centre, Max Planck Institute for Complex Fluid Dynamics, University of Twente, P.O. box 217 7500 AE Enschede, the Netherlands

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MHMarinke W. van der Helm
Marinke W. van der Helm
OHOlivier Y. F. Henry
Olivier Y. F. Henry
ABAmir Bein
Amir Bein
THTiama Hamkins-Indik
Tiama Hamkins-Indik
MCMichael J. Cronce
Michael J. Cronce
LSLoes Segerink
Loes Segerink
Here, we describe methods for combining impedance spectroscopy measurements with electrical simulation to reveal transepithelial barrier function and tissue structure of human intestinal epithelium cultured inside an organ-on-chip microfluidic culture device. When performing impedance spectroscopy measurements, electrical simulation enabled normalization of cell layer resistance of epithelium cultured statically in a gut-on-a-chip, which enabled determination of transepithelial electrical resistance (TEER) values that can be compared across device platforms. During culture under dynamic flow, the formation of intestinal villi was accompanied by characteristic changes in impedance spectra both measured experimentally and verified with simulation, and we demonstrate that changes in cell layer capacitance may serve as measures of villi differentiation. This method for combining impedance spectroscopy with simulation can be adapted to better monitor cell layer characteristics within any organ-on-chip in vitro and to enable direct quantitative TEER comparisons between organ-on-chip platforms which should help to advance research on organ function.

5 April 2008 in Nano Letters
Verified
Journal Article
Closed access
GSGeorgette B. Salieb-Beugelaar
Georgette B. Salieb-Beugelaar
JTJuliane Teapal
Juliane Teapal
JNJan van Nieuwkasteele
Jan van Nieuwkasteele
DWDaniël Wijnperlé
Daniël Wijnperlé
JTJonas Tegenfeldt
Jonas Tegenfeldt
JEJan C. T. Eijkel
Jan C. T. Eijkel

1 December 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
JDJeanne E. van Dongen
Jeanne E. van Dongen
JBJohanna T.W. Berendsen
Johanna T.W. Berendsen
JEJan C.T. Eijkel
Jan C.T. Eijkel
LSLoes I. Segerink
Loes I. Segerink
The excellent specificity and selectivity of Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/associated nuclease (Cas) is determined by CRISPR RNA's (crRNA's) interchangeable spacer sequence, as well as the position and number of mismatches between target sequence and the crRNA sequence. Some diseases are characterized by epigenetic alterations rather than nucleotide changes, and are therefore unsuitable for CRISPR-assisted sensing methods. Here we demonstrate an in vitro diagnostic tool to discriminate single CpG site methylation in DNA by the use of methylation-sensitive restriction enzymes (MSREs) followed by Cas12a-assisted sensing. Non-methylated sequences are digested by MSREs, resulting in fragmentation of the target sequence that influences the R-loop formation between crRNA and target DNA. We show that fragment size, fragmentation position and number of fragments influence the subsequent collateral trans-cleavage activity towards single stranded DNA (ssDNA), enabling deducting the methylation position from the cleavage activity. Utilizing MSREs in combination with Cas12a, single CpG site methylation levels of a cancer gene are determined. The modularity of both Cas12a and MSREs provides a high level of versatility to the Cas12a-MSRE combined sensing method, which opens the possibility to easily and rapidly study single CpG methylation sites for disease detection.

1 February 2018 in Analytica Chimica Acta
Verified
Journal Article
Open access
VPV.A. Papadimitriou
V.A. Papadimitriou
LSL.I. Segerink
L.I. Segerink
ABA. van Den Berg
A. van Den Berg
JEJ.C.T. Eijkel
J.C.T. Eijkel
The patterning of antibodies in microfluidics chips is always a delicate process that is usually done in an open chip before bonding. Typical bonding techniques such as plasma treatment can harm the antibodies with as result that they are removed from our fabrication toolbox. Here we propose a method, based on capillary phenomena using 3D capillary valves, that autonomously and conveniently allows us to pattern liquids inside closed chips. We theoretically analyse the system and demonstrate how our analysis can be used as a design tool for various applications. Chips patterned with the method were used for simple immunodetection of a cardiac biomarker which demonstrates its suitability for antibody patterning.

27 July 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
SCSongyue Chen
Songyue Chen
JNJan W. van Nieuwkasteele
Jan W. van Nieuwkasteele
ABAlbert van Den Berg
Albert van Den Berg
JEJan C. T. Eijkel
Jan C. T. Eijkel

7 September 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
WBWesley T. E. van Den Beld
Wesley T. E. van Den Beld
ABAlbert van Den Berg
Albert van Den Berg
JEJan C. T. Eijkel
Jan C. T. Eijkel
A non-manual, controllable and wafer-scale method for the spatial control of direct graphene synthesis onto silicon dioxide by controlled dewetting and evaporation of copper.