30 September 2021 in Russian Open Medical Journal
Introduction — For the Armenian language, no standardized audiometric speech perception test is available. The purpose of this research was to develop, digitally record and evaluate an Armenian multisyllabic speech audiometry test, which can be used to measure speech recognition thresholds in Armenian native speakers. Material and Methods — To create a homogeneous multisyllabic speech corpus, Armenian numerals from 10-100 with 2-4 syllables were selected as general sample and digitally recorded by a female native Armenian speaker. For equalizing the speech recognition threshold between the test items, the speech discrimination function for each numeral was subsequently evaluated by five normal hearing native Armenian listeners in an experimental study. Results — Based on the phonemic structure of the Armenian language, 20 phonemically homogeneous test lists were created. The phoneme distributions of each test list correlated significantly and positively with that of the general sample (all Pearson moment correlation coefficients >0.960; all ps <0.001). Comparison of the phoneme distributions of test lists to that of the Armenian language showed that the test lists represent the language corpus quite well. After adjusting for actual threshold levels, speech discrimination functions are comparable between all numerals used. Conclusion — The developed test lists are a phonetically homogenous representation of the Armenian language and serve as an appropriated base for future clinical measurements of speech recognition threshold in Armenian speaking listeners.
1 August 2024 in Journal of Hearing Science
Introduction: Some electrophysiological changes can occur in the auditory system in response to noise exposure with or without any permanent auditory threshold shift. The purpose of this study was to identify and measure cochlear function after noise exposure in individuals with normal hearing according to standard audiometric thresholds.Material and methods: Pure tone audiometry (PTA) over the standard 0.250–8 kHz range and at 12 kHz, as well as distortion product otoacoustic emission (DPOAE) and auditory brainstem response (ABR) testing, were performed on 42 soldiers who had participated in combat. A control group of 40 participants underwent the same tests.Results: In the noise-exposed group, significantly poorer PTA thresholds were recorded at 12 kHz. DPOAE levels were significantly low only at 4 kHz. On ABR testing, both wave I and wave V demonstrated a significant decrease in amplitude and a significant increase in latency for the noise-exposed group.Conclusions: Our findings reveal that high levels of noise can not only damage outer hair cells but also cause changes at the level of the synapses (synaptopathy) which are not evident using standard PTA tests. However, electrophysiological methods can detect some changes in cochlear function.