John O. Milewski

John O. Milewski

Auto-generated profile, based on publicly available information

John O. Milewski

APEX3D LLC, Santa Fe, NM, USA

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2020 in Nature Reviews Materials
Verified
Journal Article
Closed access
PDF file
TDTarasankar Debroy
Tarasankar Debroy
Tuhin MukherjeeTuhin Mukherjee
Tuhin Mukherjee
HWH. L. Wei
H. L. Wei
JEJ. W. Elmer
J. W. Elmer
JMJ. O. Milewski
J. O. Milewski

1 January 1994
Verified
Conference Paper
Closed access
PDF file
GLGary K. Lewis
Gary K. Lewis
RNRon Nemec
Ron Nemec
JMJohn Milewski
John Milewski
DTDan J. Thoma
Dan J. Thoma
DCDave Cremers
Dave Cremers
MBMike Barbe
Mike Barbe
Directed Light Fabrication (DLF) is a rapid prototyping process being developed at Los Alamos National Laboratory to fabricate metal components. This is done by fusing gas delivered metal powder particles in the focal zone of a laser beam that is programmed to move along or across the part cross section. Fully dense metal is built up a layer at a time to form the desired part represented by a 3 dimensional solid model from CAD software. Machine “tool paths” are created from the solid model that command the movement and processing parameters specific to the DLF process so that the part can be built one layer at a time. The result is a fully dense, near net shape metal part that solidifies under rapid solidification conditions.

18 October 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
GJGerardo Jaramillo
Gerardo Jaramillo
MCMei-Lin Chan
Mei-Lin Chan
JMJohn O. Milewski
John O. Milewski
RFRobert D. Field
Robert D. Field
DHDavid A. Horsley
David A. Horsley
We have developed a scanning magnetic microscope (SMM) based on a magnetic tunneling junction (MTJ) magnetoresistive (MR) sensor. The microscope is based on commercially available components employing two sets of scanning stages and a MTJ sensor. Spatial resolution and noise sensitivity were investigated using two MTJ sensors, one having high spatial resolution and the other low noise but coarser spatial resolution. We present measurements of magnetic field images from ferrite concentration calibration standards and a stainless steel welded specimen both imaged using a magnetoresistive scanning microscope. A sensitivity of ~ 10 μT/FN was obtained from standards with defined ferrite numbers (FN). This microscope represents a new powerful tool for the characterization and investigations of delta ferrite concentrations in stainless steel welded samples.

30 June 2017
Verified
Book Chapter
Closed access
PDF file
JMJohn O. Milewski
John O. Milewski